Page 5
iQ Series
,
Ultrasonic Generator/Power Supply LS User’s Manual
Dukane Manual Part No. 403-574-01
HOW TO - Adjust Amplitude
1. Press
CANCEL
until you see the Main Menu screen as
it is shown here.
Move the selection indicator
to PROCESS SETUP
.
2. Press
ENTER
and you will see the screen as shown
here.
3. Select
PROCESS CONTROL
, and press
ENTER
.
With no option boards installed in the generator, you will
get a
WELD BY
choice of
iQ SYSTEM
or
AUTOMATION
.
4. Select
iQ SYSTEM
, and press
ENTER
.
5. Select
AMPLITUDE CONTROL
.
6. Select
AMPLITUDE SETTING.
7. Adjust the amplitude. This is a value with a minimum
of 20% and a maximum of 100%.
Select the digits with the RIGHT and LEFT arrows. Use
the UP and DOWN arrows to select the value.
8. When done with the amplitude entry, press
ENTER
, and
an
ENTRY ACCEPTED
message will appear.
# 1:
OPERATE MODE
PROCESS SETUP
HARDWARE SETUP
PROCESS SETUP
PROCESS CONTROL
PROCESS LIMITS
UTILITIES
AUTOMATED PROBE
WELD CONTROL BY
iQ SYSTEM
AUTOMATION
WELD CONTROL
HOLD CONTROL
AFTERBURST CONTROL
AMPLITUDE CONTROL
AMPLITUDE CONTROL
AMPLITUDE SETTING
RAMP UP/ DOWN TIME
AMPLITUDE SETTING
90 %
CHANGE VALUE
SELECT DIGIT
NOTE
Once the amplitude is set and the entry
is accepted, the program takes you back
to the AMPLITUDE CONTROL screen.
From there you may adjust the RAMP
UP/DOWN times or go to some other part
of the menu.