4
6.
“LIGHT TIMER” MODE
DIP1 = OFF | DIP3 = ON | DIP4 = OFF
This mode (
DIP3
=
ON
) set the receiver to maintain active the Relay outputs for 3 minutes (useful as light timer) when it is received a radio code from a remote control,
a sensor or the “alarm” code of a TSR. The remote controls and TSR transmitters must be stored only in Relay A zones (Radio Zones A-1 ÷ A-5).
During this time the receiver will not react to any command.
DIP2
=
ON
BI-STABLE
By pressing once the BIG button of a remote control, the Relay A is activated – Pressing it again, the Relay A releases
The Relay B is activated for 3 minutes when it is received an alarm code from a sensor stored in Radio Zones B (the sensors stored in Radio Zones A are
ignored)
DIP2
=
OFF
MONO-STABLE
The Relay A is activated for 3 minutes when it is received a radio code (sensor, remote control or TSR “start alarm”) from Radio Zones A
The Relay B is activated for 3 minutes when it is received an alarm code from a sensor stored in Radio Zones B
7.
USE OF THE TSR TRANSMITTER
DIP1 = OFF | DIP3 = OFF | DIP4 = OFF
The receiver can be paired with TSR (transmitter for sirens) to visualize from remote the alarm system status.
The TSR transmitters must be stored only in Relay A zones (Radio Zones A-1 ÷ A-5). The remote controls must be stored only in Relay A zones (Radio Zones A-1 ÷ A-5).
The receiver works differently depending on
DIP2
setting:
DIP2
=
ON
BI-STABLE
The Relay A is activated when it is received the “ARM” code of a TSR, and releases when it is received the “DISARM” code
By pressing once the BIG button of a remote control, the Relay A is activated – Pressing it again, the Relay A releases
By pressing once the SMALL button of a remote control, the Relay B is activated – Pressing it again, the Relay B releases
The Relay B is activated for 2 seconds when it is received the “START ALARM” code of a TSR or an alarm code of a sensor stored in Radio Zones B
DIP2
=
OFF
MONO-STABLE
The Relay A is activated for 2 seconds when it is received an “ALARM” code of a TSR or any code of a remote control or an alarm code of a sensor stored in
Radio Zones A
The Relay B is activated for 2 seconds when it is received a “STOP ALARM” or “DISARM” codes of a TSR or an alarm code of a sensor stored in Radio Zones B
This device meets the R&TTE requirements (European Union)