2.8  Setting the Controls

The setting of the controls is explained in detail in Part 4: Microcontrol
Summary !

At this point only those settings necessary for the sewing procedure
are listed.

Turn main switch on !

The programming of the controls occurs with the main switch turned
on !
The machine is not to be started unintentionally.

Set the " Program " switch to " 01 " or " 02".
The sewing program is selected.

Push the " STOP " button.
The sewing program is activated.

Setting the seam length.
Press button " L1 "or " L2 " or " L3 ".
Set the desired value with the " + " or " - ".

Establishing the seam length with the light barrier.
Press the button.

Setting the soft start.
Press the button.
The diode is lit when the function is selected.

Setting stitch condensing at the seam beginning.
Press the button.
The diode is lit when the function is selected.

Setting stitch condensing at the seam end.
Press the button.
The diode is lit when the function is selected.

Setting the remover.
Press the button.
The diode is lit when the function is selected.

Setting the blower from the top or to the right.
Press the button.
Pressing the button repeatedly switches between the functions
"top/right/off".
The left diode is lit when the function 
" Blower from the top " is selected.
The right diode is lit when the function
" Blower from the right " is selected.

Setting the normal stitches and the stitch condensing.
Press the button.
The left line of display indicated the number (0 to 20) of regular
stitches up to the stitch condensing.
Set the desired value with the " + " or " - ".
Press the button.
The right line of display indicated the number (0 to 8) of 
condensed stitches.
Set the desired value with the " + " or " - ".
Press the button. (The engagement is finish.) 

The controls are now completely set.

13

Summary of Contents for 743-121

Page 1: ...l Equipment 6 2 Operating the Sewing Unit 2 1 Needles and Threads 6 2 2 Threading 6 2 3 Setting Thread Tension 8 2 4 Changing the Configuration Set 8 2 5 Dart Depth 10 2 6 Dart Length 10 2 7 Setting the Insertion Depth of the Folding Table 12 2 8 Setting the Controls 13 2 9 Positioning the Sewing Pieces 14 2 10 Sewing 14 3 Maintenance 3 1 Cleaning 15 3 2 Lubrication 16 ...

Page 2: ......

Page 3: ...tasks monitors the sewing process and signals operating errors and malfunctions An electronic thread monitor prevents a renewed starting of the sewing procedure by thread breakage or when the thread is used up 1 1 Technical Specification Machine head Class 935 171 100 Needle system 934 SIN Needle thickness Nm 90 Threads As needle and bobbin thread spun monofilament sewing threads Stitch type 401 D...

Page 4: ...set must be in the left end position Threading lower thread Bobbin thread Place thread spool 2 on the thread stand Alternatingly feed the thread through all 4 guide eyes of the take off arm 1 Unlock the slider bed and pull to the side Guide the thread through the thread tensioner 4 5 and the thread guide 12 Swing up the flap 13 over the thread take up disk Guide the thread to the right past the pi...

Page 5: ...1 2 3 13 14 8 9 10 11 4 5 6 7 12 13 7 ...

Page 6: ...ain switch off The configuration set may only be changed with the machine switched off Removing the configuration set Turn the handwheel until the needle is in the 2nd position OT Push the configuration set to the left end position Turn the grip 5 counterclockwise about 90 Lift the configuration set 6 at the left side and carefully detach from the transport carriage Remove the configuration set In...

Page 7: ...1 2 3 4 5 6 7 8 9 ...

Page 8: ...1 cm at 10 and 9 5 cm dart depth THe diagram shows the dart depths for other angles and lengths The curve for configuration set 0793 078002 is also shown Setting the angle Press the handle 2 together and adjust the folding table according to the scale 1 Release the handle The angle is set 2 6 Dart Length Maximum dart length 150 mm The dart length control occurs via programming Buttons L1 L2 L3 or ...

Page 9: ...8001 4 Configuration set 0793 078002 Work range waist pleat Waist pleat length cm Example with configuration set 0793 078034 1 Waist pleat depth max 3 2 cm at 5 Length 5 cm 2 Waist pleat depth max 2 5 cm at 0 Length 6 cm 3 Configuration set 0793 078034 Angle adjustment range Range of shapes Dart length cm Pleat width min Parallel adjustment range Angle adjustment range Range of shapes 11 ...

Page 10: ...wing unit turned off Setting the insertion depth Release lever 3 Push the folding table a bit forward on the guide Set one adjusting screw 4 7 off to the desired insertion depth Turn setting knob 2 to the desired insertion depth stop Push the folding table to the back on the guide again The adjusting screw 4 must firmly touch the stop 1 Tighten lever 3 again Changing the insertion depth Release le...

Page 11: ...button The diode is lit when the function is selected Setting stitch condensing at the seam end Press the button The diode is lit when the function is selected Setting the remover Press the button The diode is lit when the function is selected Setting the blower from the top or to the right Press the button Pressing the button repeatedly switches between the functions top right off The left diode ...

Page 12: ...ation set The fold plate runs to the back The sewing procedure is carried out 2 10 Sewing After the main switch is turned on or the STOP button is pushed the microcomputer checks the initial settings of the machine The needle is brought to its initial position If no fault is found the REF or REF display will appear This means that the configuration set must be run to the reference point Press the ...

Page 13: ...malfunctions Daily cleaning Remove all accumulations of lint Clean the light barrier with a soft cloth Check the water level in the pressure regulator The water level should not be allowed to climb up to the filter After screwing in the drain plug 1 blow out the water under pressure Depending on the amount of dust present Clean the motor ventilation sieve Clean the filter 2 on the step motor drive...

Page 14: ... oil level of the sewing unit is to be checked weekly The inspection glass 2 must be half full Fill up only with ESSO SP NK 10 oil 1 oil filler screw SP NK 10 can be obtained from the DÜRKOPP ADLER AG sales offices 1 2 16 ...

Reviews: