Operation and Maintenance Manual

Manufacturer Address:

Ducts and Cleats

200 W. Plato Blvd.

St. Paul, MN 55107

Phone: 651-265-0600

Email: [email protected]

Summary of Contents for ISO-Aire RSF1000

Page 1: ...Operation and Maintenance Manual Manufacturer Address Ducts and Cleats 200 W Plato Blvd St Paul MN 55107 Phone 651 265 0600 Email info ductsandcleats com...

Page 2: ...ing to local regulations Contamination hazard If unit is used in hazardous or potentially hazardous environments such as mold mitigation job sites Intended Use The ISO Aire commercial air purifier is...

Page 3: ...id surface When moving the unit WARNING Do not place objects on top of the discharge plenum Keep hands and face away Rotating blower wheel can cause serious injury Wear gloves when handling MOVING PAR...

Page 4: ...num de d charge Gardez les mains et le visage loign s La roue de soufflante en rotation peut causer des blessures graves Portez des gants lors de la manipulation RISQUE DE PI CES EN MOUVEMENT ET DE BO...

Page 5: ...ipolar ionization and UVC sterilization These air purification technologies are paired with a powerful commercial grade fan for a long life and high quality solution Models are variable speed and are...

Page 6: ...e a minute for the fan to ramp up and come to the set speed due to a grid friendly motor feature The ISO Aire commercial air purifier is easy to install and plugs into a standard 110 volt outlet The s...

Page 7: ...mps 5 9 Fan Total Static Pressure 1 5 W G Optional UVC Full Load Amps 1 36 Optional Bipolar Ionization Full Load Amps 0 41 300 400 CFM Models RSF250 RSF300 500 CFM Models RSF500 750 CFM Models RSP750...

Page 8: ...PREF12121 change every 3 months If using a standard capacity pre filter change every 2 months 400 CFM Models RSF300 Size 14 x 16 x 1 MERV 8 High Capacity Pre Filter Part Number PREF14161 change every...

Page 9: ...high capacity HEPA filter When ordering a replacement filter use the part number below to purchase from the OEM filter the unit came with Failure to use proper filtration will void warranty and could...

Page 10: ...according to local laws ISO Aire is available with UVC sterilization which has been carefully designed into our unit to ensure efficacy and proper exposure duration to pathogens The UVC is properly c...

Page 11: ...nserting sideways Figure A twisting so the bulb fits in the securing tabs Figure B and then pushing the bulb into the four pin connection Figure C Slide the metal reflective cover over the entire UVC...

Page 12: ...n concentrations in the space and also for the ideal pairing with higher filtration from our HEPA filter Caution Never touch the ionizer brushes while operating shock may occur Ozone Free Bipolar Ioni...

Page 13: ...tch and can be adjusted as needed Use the tables below based on your model for CFM at various fan speed Be sure to check the fan speed control during initial setup to confirm it is at the desired spee...

Page 14: ...closure does not fall when the screws are removed in step 2 See Figure A Next release the enclosure for removal from the inner core by removing the 11 screws along the bottom on each side 3 screws on...

Page 15: ...nner core and set the enclosure off to the side Now that the inner core is exposed remove the lower bolt on each filter bracket one on each side 4 total See Figure D then lift the fan assembly back on...

Page 16: ...lacing the HEPA or pre filter ensure the unit is first turned off See pages 5 and 6 for filter part numbers sizes and service intervals To replace the HEPA release the enclosure for removal from the i...

Page 17: ...core and set the enclosure off to the side Now that the inner core is exposed remove the lower bolt on each filter bracket one on each side 4 total See Figure D then lift the fan assembly off of the f...

Page 18: ...5 and 6 for filter part numbers sizes and service intervals The HEPA filter is secured using a tensioning mechanism which holds the filter secure in place To replace remove the rear service panel see...

Page 19: ...e main rear service panel by removing the 14 screws see Figure A Then remove the intake grille on each side of the unit see Figure B Then the tensioning bolts can be accessed Lower the HEPA filter by...

Page 20: ...r filter part numbers filter sizes and service intervals The HEPA filter is secured using a tensioning mechanism which holds the filter secure in place To replace lower the HEPA filter from the frame...

Page 21: ...oving the HEPA See pages 5 and 6 for filter part numbers filter sizes and service intervals The HEPA filter is secured using a tensioning mechanism which holds the filter secure in place To replace lo...

Page 22: ...irect incidental or consequential damages of any kind The limited warranty of any products replaced or repaired under this Limited Warranty shall be limited to the remainder of the original warranty p...