DuctlessAire 15 seer User Manual Download Page 6

9

10

CARE AND MAINTENANCE

Care and Maintenance

Filter Handle

OPERATING INSTRUCTIONS

How the air conditioner works

1 hour

1 hour

Set
Temperature

Set
Temperature

Cooling

Heating

SLEEP operation

1 hour 1 hour

SLEEP operation

7 hours timer off

7 hours timer off

AUTO operation

SLEEP operation

DRYING operation

Optimal operation

When you set the air conditioner in AUTO mode, it will
automatically select cooling, heating(cooling/heating
models only), or fan only operation depending on set
temperature and the room temperature.
The air conditioner will control room temperature
automatically to the temperature point you set.
If you feel uncomfortable in the AUTO mode, you can set
your desired temperature.

When you push SLEEP button on remote controller
during cooling, heating(cooling & heating models only),
or AUTO operation , the air conditioner will
automatically increase (cooling) or decrease (heating)

per hour for the first 2 hours, then hold

steadily for the next 5 hours, after that it will switch off.
This mode saves you energy and brings you comfort
at night.

To achieve optimal performance, please note the
following:
Adjust the air flow direction correctly so that it is not
forwards people.
Adjust the temperature to achieve the highest comfort
level. Do not adjust the unit to excessive temperature
levels.
Close doors and windows on COOL or HEAT modes,
or performance may be reduced.
Use TIMER ON button on the remote controller to
select a time you want to start your air conditioner.
Do not put any object near air inlet or air outlet, as the
efficiency of the air conditioner may be reduced and
the air conditioner may stop running.
Clean the air filter periodically, otherwise cooling or
heating performance may be reduced.
Do not operate unit with horizontal louvre in closed
position.

The fan speed will be automatically controlled under
dry operation.
During the dry operation, if the room temperature is
lower than 10 C(50 F), the compressor stops operation
and restarts until the room temperature is above
12 C(54 F).

O

O

O

O

Before mainatenance

A cloth dampened with cold water may be used

on the indoor unit if it is very dirty. Then wipe it
with a dry cloth.
Do not use a chemically treated cloth or duster to
clean the unit.
Do not use benzine, thinner, polishing powder, or
similar solvents for cleaning. These may cause

the plastic surface to crack or deform.
Never use water hotter than 40 C/104 F to clean
the front panel, it could cause deformation of
discoloration.

CAUTIONS

Turn the system off before cleaning. To clean, wipe with
a soft, dry cloth. Do not use bleach or abrasives.

NOTE: Power supply must be disconnectd before
cleaning the indoor unit.

wipe the unit with a soft dry cloth only. If the unit is
very dirty, wipe it with a cloth soaked in warm water.

A clogged air filter reduces the cooling efficiency of
this unit. Please clean the filter once every 2 weeks.
1. Lift the indoor unit panel up to an angle until it

stops with a clicking sound.For some models,
please use suspension bars to prop up the panel.

2. Take hold of the handle of the air filter and lift it

up slightly to take it out from the filter holder,
then pull it downwards.

3. Remove the AIR FILTER from the indoor unit.

Clean the AIR FILTER once two weeks.
Clean the AIR FILTER with a vacuum cleaner
or water, then dry it up in cool place.

Cleaning the unit

Cleaning the air filter and air freshening filter

4. Remove the Air Freshening Filter from its supporting

frame (on some models).

Clean the air freshening filter at least once a

month, and replace it every 4-5 months.

Clean it with vacuum cleaner, then dry it in cool

place.

Air freshening filter

Summary of Contents for 15 seer

Page 1: ...ve care on your part can save you a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of troubleshooting tips If you review the chart of Troubleshooting Tips first you may not need to call for service The design and specifications are subject to change without prior notice for product improvement Consult with the sales agenc...

Page 2: ...n the European countries please read the following information This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the app...

Page 3: ...l the air conditioner in places where combustible gas can be emitted Emmitted gas may collect and cause an explosion Never allow the air conditioner to run for too long with the doors or windows open or if the humidity is very high Remove all dirt from the power plug and plug it firmly Soiled plugs can cause fire or an electric shock In the event of any abnormalities such as smell of burning immed...

Page 4: ...e it will memorize the open angle of horizontal louver If it exceeds it will memorize the boundry of safety angle In the following circumstances it will return to standard angle 1 pressing the manual control button 2 unplug and then plug in the machine So we strongly suggest that the open angle of the horizontal louver should not be set too small in case the condensed water forms and drops from th...

Page 5: ...emote Controller Instruction packed with the unit for details Operating temperature Manual switch Manual switch Mode Temperature Room temperature Outdoor temperature 1 Optimum performance will be achieved within these operating temperatures If air conditioner is used outside of the above conditions certain safety protection features might come into operation and cause the unit to function abnormal...

Page 6: ...may be reduced Do not operate unit with horizontal louvre in closed position The fan speed will be automatically controlled under dry operation During the dry operation if the room temperature is lower than 10 C 50 F the compressor stops operation and restarts until the room temperature is above 12 C 54 F O O O O Before mainatenance A cloth dampened with cold water may be used on the indoor unit i...

Page 7: ...s only A white mist coming out from the indoor unit Low noise of the air conditioner Dust is blown out from the indoor unit A peculiar smell comes out from the indoor unit 6 When indoor temperature reaches the temperature setting on air conditioner the compressor will stop automatically and the air conditioner turns to FAN only mode The compressor will start again when the indoor temperature rises...

Page 8: ...itioner The remote controller won t work or works abnormally Trouble OPERATION indicator or other indicators continue flashing If one of the following code appears on the display area E0 E1 E2 E3 or P0 P1 P2 P3 TROUBLESHOOTING TIPS Troubleshooting guide 8 Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humidity relative humidity higher than 80 Adjust...

Reviews: