30
D U C A T I
e l e c t r o n i c b o a r d
C T H 4 2 “
S t a n d a r d l e v e l ”
Connections and adjustments:
ATTENTION ! all settings have to be made with
gate in closed position
CONNECTORS:
1/2 antenna / sock
3/5 START contact NO full opening cycle
4 photocells NC contact
5 common ( photocells & START)
8/9 START contact NO for pedestrian opening cycle
10 + power photocell positive
11 - power photocell negative
12/13 12V 10W max. blinking light
14 M2 actuator blue cable
15 M2 actuator brown cable
16 M1 actuator blue cable
17 M1 actuator brown cable
18/19 output for garden/courtesy light
(contact NO/NC max 0,5A) use a relay if ac
20/2112V ac electrolock output
protection fuse 10AF
Connectors (BAT+/-) to battery charger module CBAT
Transformer imput: 0= black cable + 2V yellow cable
The phase shift in between gate wings is
automatically set.
M2 follows M1 in opening after about 3 sec. and vice
versa during closing.
Photocells bridge: between connectors 4/5
Remove the bridge only when connecting the photo-
cells.
Red LED:
- indicate the procedure to memorize/delete remote
ontrols codes
- while gate is open: it blinks if the automatic closure
has been activated
Green LED:- if steady on = the board is powered
PUSH BUTTONS P1; P2; J1
P1 = FULL CYCLE push button to store or cancel the radio transmitters codes on the electronic board.
This button is used to set complete opening cycles. Red LED visual indicator.
J1 = PEDESTRIAN ACCESS push button to store or cancel the radio transmitters codes on the electronic
board. This button is used to set pedestrian opening cycles (partially activates only the door corresponding to
the motor M1 only ). Visual indicator: red LED visual ind yellow LED, then only red LED.
P2 =deactivate/activate the Gear anti-pressure system ( with the anti-pressure-system activated the gate
reaches the mechanical limit it will invert the direction for 0,25sec to release pressure on wing inghes and ac-
tuator’s gear). This function is automatically set in the board. To delete this feature, proceed as follows: press
P1 for 1 second. the red LED lights. Press P2 for a second. function deactivated. To restore the function, repeat
the procedure.
JP1 SWITCH
JP1 switched on position 1= 1 wing gate use
JP1 switched on position 2= 1 wing gate use
0= step by
step
max100 sec.
automatic
closure
Power
M1
Power
M2
Time
CTH42
T1
T2
T3
-
CMBAT
to board
sol -
sol +
to batt
-
-
0
12V
trasformer
230(110V)
0,8A
T (1,2A
T)
START
START
Pedonale
+ -
photocells
courtesy
timerized
light
12V ac
electrolock
output
A)
Garden
courtesy timerized light
12V max 10W
B)
Garden courtesy timerized light powe-
red by 230V /110V
A)
AC
1
2
JP1
FTC
NC
12V
10W
max
M1
M2
J1
12V solar panel
-
HOW TO MEMORIZE/ DELETE REMOTE CONTROL CODE IN THE
ELECTRONIC BOARD ( see also remote control chapter)
Remote controls setting: to syncronize a remote control channel:
On the main board Press P1 to memorize a remote control Channel for compleete opening cycle.
Release P1.As the red LED turns on, push the selected radio remote control button. After the red LED
blinks, wait until the red LED turns off. Operation completed.Maximal storage capacity: 10 channels
To delete the stored channels press P1 for about 30 sec. until the red LED turns off.
All remote control codes will be delated.
POTENTIOMETERS
TIME
=
potentiometer to set the “step by step” mode of use or automatic closure
The potentiometer completely turned counterclockwise( position = 0 ) to use the standard setting “step by
step” mode of use. with this setting a pulse controls the opening and a second impulse closes the gate.
By rotating the potentiometer clockwise, you will set the automatic closure function.Turning the knob in-
creases the time. Maximum pause time = 100 seconds with potentiometer fully clockwise.
POWER M1:
actuator M1 power /obstacle detection sensitivity adjustment
POWER M2:
actuator M2 power /obstacle detection sensitivity adjustment
Turn the potentiometer clockwise to increase power and reduce obstacle detection sensitivity