INSTALLATION INSTRUCTIONS
Electrical Connection
A qualified electrician must carry out the electrical installation of this radiator. The electrical installation
must comply with the current UK regulations. Any claim on the warranty could be invalid if these
requirements have not been met.
The radiator requires a 230/240V 50/60Hz power supply.
Connecting wires:
Brown: Live
Blue: Neutral
Yellow-green: Earth (only for Class I radiators)
The connecting wires must be of the appropriate section, in regards to the length of cable, type of cable and power rating
of the apparatus.
The apparatus must be connected into a connecting box.
We recommend that the connecting box is positioned 10cm to the right of the apparatus and at 15cm above the floor.
According to regulations, the apparatus must be connected to the power supply by means of an all-pole circuit breaker
with a contact gap of at least 3mm or by a thermal-magnetic circuit breaker.
Location
The ideal place to site the Ducasa radiator is as close as possible to coolest wall in the room but it is not recommended to
site the radiator on un-insulated exterior walls, in this case, the part of the wall behind the radiator should be insulated.
In bathrooms, the radiators must not be sited inside the protected area. The control unit switches must not be reachable,
directly or indirectly, by a person in the bath or shower.
The radiator, under no circumstances, should be installed below an electric power point.
Choose the location of the radiator in respect of the minimum distances that are indicated in Figure A.
window sill
150mm.
150mm. min.
unobstructed space each side
150mm.
Fig. A