Wipe the external surfaces of the Base with mild detergent (washing up liquid) and 

a soft, damp cloth. Note: Do not submerge in water and ensure no water goes into 

the Air Vent. Do not use sharp articles or metal tools to touch the Element as it may 

cause electric shock. Do not submerge the Base, the power cord or the plug in water 

or other liquid or position under a water tap. Do not use sharp, abrasive or aggressive 

cleaning agents, bleach, or scouring pads to clean the Steriliser. The use of such 

cleaning implements may affect the life of the Steriliser. 

Note: When not in use 

clean and dry the Steriliser and store in a cool, dry place.

2

Unplug the Steriliser from 

the mains and allow to cool 

down completely before 

cleaning.

If any water is left in the 

Steriliser after use, pour 

away and replace with fresh 

water before starting a new 

sterilising cycle. Caution: 

Pour water towards a 

front corner to ensure that 

no water goes into the 

Air Vent. Risk of fire and 

electric shock.

Do not pour unused or 

excess water out at any 

other angle. 

Over a sink, pour away any 

water remaining in the Water 

Recess. 

Note: Pour water 

towards a front corner 

to ensure that no water 

goes into the Air Vent. 

Risk of fire and electric 

shock.

 

If you wish to turn the 

Steriliser off during a 

sterilisation cycle, turn the 

Control Dial to “O” setting 

and unplug.

The Steriliser needs to cool down after a function cycle before it can be used 

again for a new sterilising process.

Note: If you leave the lid on your Steriliser the items will remain sterilised 

for up to 24 hours. The Steriliser needs to cool down for 10 minutes after a 

function cycle before it can be used again for a new sterilising process.  

Warning: If you turn off the sterilisation cycle before it finishes, the items will 

not be sterile. 

3

Clean all surfaces of the 

Upper Rack, Lower Rack, 

and Lid with mild detergent 

(washing up liquid) and a 

soft, damp cloth. 

Note: Do not use sharp, 

abrasive or aggressive 

cleaning agents, bleach, 

or scouring pads to 

clean the Steriliser. The 

use of such cleaning 

implements may affect 

the life of the Steriliser.

1

4

13

14

15

CLEANING & CARE

Before cleaning make sure the appliance is switched off, 
unplugged and allowed to cool. Dualit recommends cleaning 
your Steriliser regularly.

U

N

PL

U

WH

EN NO

T IN

 U

SE

DON’T FORGET 
TO 

REGISTER  

YOUR PRODUCT

WWW.DUALIT.COM/REGISTER

OR BY POST

Summary of Contents for baby 11040

Page 1: ...Steam Steriliser Instruction Manual Guarantee DON T FORGET TO REGISTER YOUR PRODUCT WWW DUALIT COM REGISTER OR BY POST...

Page 2: ...Unpack the box with care keeping all the packaging materials until you are satisfied everything is present and in working order Once satisfied remove any tags from the appliance body and recycle the...

Page 3: ...gled in or tripping over a longer cord Do not allow cable to hang over the edge of a table or countertop Do not fill above the max mark on the water level indicator Risk of fire and electric shock Do...

Page 4: ...will be sterile for 24 hours after cycle as long as the lid isn t removed FILTER HOLDER FILTER BASE FEET ICON FUNCTION DESCRIPTION Sterilise Only Sterilise up to 6 full bottles This function kills 99...

Page 5: ...surfaces and steam vents Risk of scalding Before first use wash the Upper and Lower Racks and the Lid with warm soapy water and rinse thoroughly Do not submerge the Base Power Cord or Plug as there i...

Page 6: ...uick Dry Without water this function will dry items that have been sterilised only and are still wet or dry any items that require a longer drying cycle 30 minutes FUNCTION DESCRIPTION TIME Sterilise...

Page 7: ...ning in the Water Recess Note Pour water towards a front corner to ensure that no water goes into the Air Vent Risk of fire and electric shock If you wish to turn the Steriliser off during a sterilisa...

Page 8: ...The Steriliser can be descaled by pouring just boiled water into the Water Recess up to the MAX marker then adding 30ml of Kilrock Espresso Coffee Machine Descaler This can be purchased on www dualit...

Page 9: ...liser Element may have a build up of limescale This will show as white and or brown spots on the Steriliser Element and Water Recess 1 Descale your Steriliser regularly please see Descale section 2 Yo...

Page 10: ...as purchased or to Dualit direct Ensure that the product is clean and packed carefully preferably in its original carton Enclose details of your name address and telephone number and when and where th...

Page 11: ...ounty Oak Way Crawley West Sussex RH11 7ST 44 0 1293 652 500 info dualit com www dualit com GB A A feeding and weaning range designed to make everyday baby life that bit easier ORDER THE FULL RANGE AT...