08.   Function configuration (Communication setting) 

Changing  the  reader  settings  is  also  possible  using  the  SDK  (DualCard  program)  provided  by 
DUALi.  You can easily change  the setting of  DQ-MINI by  executing the corresponding command 
referring to the communication frame below. (For more information on dual  cards, please refer to 
DUALi SDK Manual.) 

 

 

 

 

 

 

 

 

STX

,  LENH  (Length  High)  and  LENL  (Length  Low)  value  of  each  communication  frame  are 

automatically  calculated  in  the  dual  card  program.  Just  input  corresponding  value  on  each  CMD/ 
DATA fields.

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for DQ-MINI

Page 1: ...other than those for which this document is disclosed This document is copyrighted and contains confidential information and other intellectual property rights of DUALi Inc Any unauthorized use copy disclosure or distribution constitutes infringement of DUALi s intellectual property rights DUALi Inc Document Version 1 00 Last Revised Date 20th SEP 2018 Release Date 25 November 2009 ...

Page 2: ...DQ MINI User Manual Version 1 00 www duali com 2 Revision History 2018 09 20 Ver 1 00 First Release ...

Page 3: ...nt of patents and or any other intellectual or industrial property rights of third parties which may result from assistance provided by DUALi Composition of the information in this manual has been done to the best of our knowledge DUALi does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete...

Page 4: ...peration Usage 10 07 Output Format 10 08 Function configuration Communication setting 12 08 1 Wiegand option set Parity Reverse 13 08 2 LED option setting 14 08 3 Mifare KEY type Block number ID position Wiegand format option set 14 08 4 QR Mode option set 16 08 5 QR Reading timeout 17 08 6 QR scan interval set 18 08 7 QR Maximum length set 19 08 8 QR data send channel set 20 08 9 RF Scan option s...

Page 5: ...ial Type Contactless ISO 14443 TYPE A and B Mifare FeliCa ISO 15693 ISO 18092 NFC Option Contact SAM ISO7816 Class A 5V 2 SAM Card Slot 1D 2D QR Recognizable spec UPC EAN UPC EAn with Supplementals Bookland EAN ISSN UCC Coupon Extended Code Code128 GS1 128 ISBT 128 Code 39 PDF417 MicroPDF417 Composite Codes Data Matrix Maxicode Qr Code micro QR Aztec Indicator LED RED BLUE Magnetic Buzzer Power Su...

Page 6: ...DQ MINI User Manual Version 1 00 www duali com 6 03 Contents Confirmation DQ Mini with Wiegand or USB cable Wall bracket Screw Option PC Test FW download zig ...

Page 7: ...icator Bracket Place the provided wall mount bracket on the wall and fix it tightly with screw Φ4mm Flat head Connect the power and communication cable to DQ MINI s terminal block In case you don t use the cable as it is shipped you could cut off the end of the cable and use only the wire that you need for connection RF Field 1 2D barcode detector ...

Page 8: ...d machine screw Caution Do not push the bracket too hard when fixing it to the wall Screw has to be selected depending on the wall s material and condition Place the reader to flat panel between the wall mount bracket and the wall It could cause a problem to assemble the device if the bracket is bent Card reading distance can be short if the wall is made of steel or metal ...

Page 9: ... com 9 05 Connection Diagram PIN NAME COLOR PIN NUMBER PWR_IN RED 1 PWR_GND BLACK 2 RS232_RX GRAY 3 RS232_TX PINK or JADE 4 WGD_D0 GREEN 5 WGD_D1 WHITE 6 PWR_GND BLUE 7 LED BROWN 8 BEEP YELLOW 9 TAMPER VIOLET 10 RS485 ORANGE 11 RS485 SKYBLUE 12 ...

Page 10: ...l to access controller In case of closed CASE TAMPER line VIOLET shows 0V and otherwise open shows 5V LED Control Reader turns on RED LED when LED Signal BROWN with 0V In case of 5V BLUE LED will be on Buzzer Control Reader makes beep sound when BEEP Signal YELLOW with 0V 07 Output Format Data format Data format can be decided by setting Refer to chapter 10 ...

Page 11: ... of bit 18 bit 33 First Bit Parity Even parity of bit 2 bit 33 Data 1 64 ID number transmission data FeliCa card IDM data 8bytes Mifare card Card serial number 4bytes 0x00 4bytes Last Bit Parity Odd parity of bit 34 bit 65 32bit Data 1 32 ID number transmission data 64bit Data 1 64 FeliCa card IDM data 8bytes Mifare card Card serial number 4bytes 0x00 4bytes ...

Page 12: ...y DUALi You can easily change the setting of DQ MINI by executing the corresponding command referring to the communication frame below For more information on dual cards please refer to DUALi SDK Manual STX LENH Length High and LENL Length Low value of each communication frame are automatically calculated in the dual card program Just input corresponding value on each CMD DATA fields ...

Page 13: ...he reader does not need to be set again 115 200bps 8 data no parity 1 stop bit STX LENH LENL CMD DATA LRC 0x02 0x00 0x02 0xE0 DATA 0 LENH LENL CMD DATA 0 DATA 0 State Description Bit0 RFU Bit1 0x02 Reverse ON Bit2 0x04 Parity OFF Bit3 7 RFU 00 Parity OFF Reverse OFF 02 Parity OFF Reverse ON 04 Parity ON Reverse OFF 06 Parity ON Reverse ON exclusive oring Tip To change the Wiegand option to Parity ...

Page 14: ...ition Wiegand format option set Following is the communication frame for Mifare KEY type Mifare block number Mifare ID position Wiegand format option set Since it is saved in flash memory after the first setting the reader does not need to be set again 115 200bps 8 data no parity 1 stop bit STX LENH LENL CMD DATA 0 LRC 0x02 0x00 0x02 0xE1 0x00 BLUE LED Default 0x01 RED LED Default LENH LENL CMD DA...

Page 15: ...escription DATA 0 Mifare KEY type 0 A KEY 1 B KEY DATA 1 Mifare Block Number Mifare Block Number 0 0xFF 0 UID DATA 2 7 Mifare Key Default Key is 0xFFFFFFFFFFFF DATA 8 Mifare ID Position ID Position DATA 9 Wiegand Length Wiegand Data length 0x04 Wiegand 32bit 0x07 Wiegand 56bit Else anything Wiegand 64bit Refer to 9 1 to set Parity option exclusive oring Tip To set Mifare Reading condition as 1 A K...

Page 16: ...e reader does not need to be set again 115 200bps 8 data no parity 1 stop bit STX LENH LENL CMD DATA 0 DATA 1 LRC 0x02 0x00 0x02 0xE3 0x00 DATA 1 LENH LENL CMD DATA 0 DATA 1 DATA 1 State Description 0x00 Presentation mode QR scan mode change to Presentation mode 0x01 Manual Trigger mode QR scan mode change to Manual trigger mode exclusive oring Tip To change the QR Mode to Presentation mode ...

Page 17: ...g the reader does not need to be set again 115 200bps 8 data no parity 1 stop bit STX LENH LENL CMD DATA 0 DATA 1 LRC 0x02 0x00 0x02 0xE3 0x01 DATA 1 LENH LENL CMD DATA 0 DATA 1 DA TA 2 DATA 1 State Description 0x05 0x32 Timeout Parameter Set same QR reading timeout Range 05 0x32 50 Each numbers are automatically multiplied by DQ MINI exclusive oring Tip To set the same QR read timeout for 1 6s 16...

Page 18: ...es not need to be set again 115 200bps 8 data no parity 1 stop bit STX LENH LENL CMD DATA 0 DATA 1 LRC 0x02 0x00 0x02 0xE3 0x02 DATA 1 LENH LENL CMD DATA 0 DATA 1 exclusive oring DATA 1 State Description 0x02 0x1E QR Scan interval QR Scan Interval setting Range 0x02 0x1E 30 Each numbers are automatically multiplied by DQ MINI THIS MODE IS ONLY WORK ON QR MANUAL TRIGGER MODE Tip To set the QR scan ...

Page 19: ...flash memory after the first setting the reader does not need to be set again 115 200bps 8 data no parity 1 stop bit STX LENH LENL CMD DATA 0 DATA 1 LRC 0x02 0x00 0x02 0xE3 0x03 DATA 1 LENH LENL CMD DATA 0 DATA 1 DATA 1 State Description 0x01 0x10 QR Maximum length QR Maximum length setting Range 0x01 0x10 16 I exclusive oring Tip To set the maximum QR length to 16 ...

Page 20: ... the first setting the reader does not need to be set again 115 200bps 8 data no parity 1 stop bit STX LENH LENL CMD DATA 0 DATA 1 LRC 0x02 0x00 0x02 0xE3 0x04 DATA 1 LENH LENL CMD DATA 0 DATA 1 DATA 1 Description 0x01 Wiegand Send ON 0x02 RS 232 Send ON 0x04 RS 485 Send ON exclusive oring Default setting is Wiegand and RS 232 send ON Tip To set the QR data send via Wiegand and RS 232 ...

Page 21: ...setting the reader does not need to be set again 115 200bps 8 data no parity 1 stop bit STX LENH LENL CMD DATA 0 DATA 1 LRC 0x02 0x00 0x02 0xE3 0x06 DATA 1 LENH LENL CMD DATA 0 DATA 1 DATA 1 Description 0x40 TYPE B Scan ON 0x20 Felica Scan ON 0x08 15693 Scan ON exclusive oring Reading Mifare Type A can not be turned off Tip To set the reader to read Mifare type A FeliCa and TypeB ...

Page 22: ...alled and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference b...

Page 23: ...y User s misuse of part component against the provided manual Fault by the unqualified user s own intention of repairs Adding certain functions or extension of system PRECAUTIONS Do not drop the device Do not modify repair or disassemble Do not expose directly to water alcohol benzene etc for cleaning Do not expose directly to flammables Do not place or keep the device near flammables Keep the dev...

Page 24: ...lease contact our service team for the technical sales supports DUALi Inc Innoplex 1dong 309ho 306 Sinwon ro Yeongtong gu Suwon si Gyeonggi do Republic of Korea 16675 Tel 82 31 213 0074 Fax 82 31 213 0078 E mail lab duali com Web site http www duali com ...

Reviews: