2- IMPORTANT SAFETY INFORMATION 

2.1 Fire prevention:

-XM2500 is fitted with a Philips 1200W MSR/SA lamp.
-Other recommended lamps are: Osram HTI 1200W/SE PP; GE Lighting CSR1200W SA
 The use of any other alternative lamp is not recommended and will null and void the fixture's warranty.
-Never locate the fixture on any flammable surface.
-Minimum distance from flammable materials: 1 m.
-Minimum distance from the closest illuminable surface: 1 m.
-Replace any blown or damaged fuses only with those of identical value. Refer to the wiring diagram if 
there is any doubt.
-Connect the projector to mains power via a thermal magnetic circuit breaker.

2.2 Prevention of electric shock:

-High voltage is present inside the unit. Unplug the unit  prior to performing any function which involves 
touching the inside of the moving head, including lamp replacement.
-The level of technology inherent in the XM2500 requires the assistance of specialised personnel for all 
servicing.Please refer to an authorised D.T.S. service centre.
-A good earth connection is essential for proper functioning of the projector.
-Never connect the unit without proper earth connection.
-The fixture should  be located in places with a good air ventilation.

2.3 Protection against ultraviolet radiation:

-Never turn on the lamp if any of the lenses, filters or ABS covering is damaged. Their respective 
shielding functions will only operate efficiently if they are in perfect working order.
-Never look directly  the lamp when it is on.

2.4 Safety:

-The projector should always be installed with bolts, clamps and other tools that are capable of 
supporting the weight of the unit.
-Always use a second safety chain to sustain the weight of the unit in case of the failure of the main 
fixing point.
-The external surface of the unit, at various points, may exceed 70°C. Never handle the unit until at 
least 10 minutes have elapsed since the lamp was turned off.
-Always replace the lamp if any physical damage is evident.
-Never install the fixture in an enclosed area lacking sufficient air flow. The ambient temperature should 
not exceed 40°C.
-A hot lamp may explode, so always wait for at least 10 minutes prior to attempting to replace the lamp.
-Always wear suitable hand protection when handling the lamp.

2.5 Level of protection against the penetration of solid and liquid matter:

-The projector is classified as an ordinary appliance and its protection level against the penetration of 
solid and liquid matter is IP 20. XM2500 uses Philips 1200 MSR/SA lamp with GY 22 socket. 
The temperature inside the projector can reach 250° C after just 5 minutes, but it can get as high as 
350° C. Always check that the lamp is cold before attempting to remove it. In any case, only open the
unit 10 minutes after it has been turned off 

ARC 1200

5

XM 2500 SPOT

Summary of Contents for XM 2500 Sport

Page 1: ...XM 2500 SPOT XM 2500 SPOT GB User Manual Rel 1 0...

Page 2: ...s or circuits described herein Les informations contenues dans le pr sent manuel ont t r dig es et contr l es avec le plus grand soin Nous d clinons toutefois toute responsabilit en cas d ventuelles i...

Page 3: ...liquids 5 3 Movement 5 4 Risk of fire 5 5 Forced ventilation 5 6 Ambient temperature 6 MAINS CONNECTION 8 6 1 Protection 7 DMX SIGNAL CONNECTION 8 7 1 DMX Addresses 7 2 Selecting the DMX address 8 DI...

Page 4: ...ris 2 gobo wheels 6 indexable 16 bit gobos open each CMY linear colour mixing system Colour wheel 7 colours open 3 rotating prisms Frost Electronic or magnetic ballast Pan 540 in 5 6 seconds 8 or 16 b...

Page 5: ...lenses filters or ABS covering is damaged Their respective shielding functions will only operate efficiently if they are in perfect working order Never look directly the lamp when it is on 2 4 Safety...

Page 6: ...SE UNDUE FORCE ON THE GLASS In case of difficulty read again the instructions and repeat the procedure 3 Replace the lamp assembly and tighten the screws A B C D which were previously removed photo 4...

Page 7: ...rn fast locks placed on the base of the units allow by using the two Omega Clamps provided in the box to fix the unit in any position Safety chain We recommend the use of a safety cable or chain conne...

Page 8: ...projector should never be installed in places that lack a constant air flow The ambient temperature should NOT exceed 40 C 6 MAINS CONNECTION XM2500 operates at 190 245V at 50 or 60Hz Prior to connec...

Page 9: ...s follows 1 Remove the 4 screws fixing the display cover panel to the unit photo 1 2 Remove the screws that fix the XLR connectors to the panel photo 2 3 Rotate the electronic card by 180 photo 3 4 Pl...

Page 10: ...ojector 1 A001 Projector 2 A031 If you want to select the next projector just add 30 Projector 3 A061 A Projector 6 A151 Changing the DMX address 1 Press the UP DOWN key until you reach the required D...

Page 11: ...ION To reverse Pan movement from left to right and vice versa on DMX level variation Up Down Counterclockwise Clockwise Up Down MENU ENTER Up Down TILT MOVEMENT INVERSION To reverse Tilt movement from...

Page 12: ...lectronic lamp sensor ACC Lamp strikes counter MENU ENTER Up Down RESET Al motors reset MENU ENTER DEFAULT To restore default setting ENTER Up Down Up Down RESET ENABLED VIA DMX RESET DISABLED VIA DMX...

Page 13: ...TION DISABLE GOBO ROTATION ENABLE MENU Up Down ENTER RESERVED Pan lock Tilt lock Pan free Tilt free Up Down ENTER Up Down ENTER Up Down ENTER ENTER Up Down ENTER ENTER Up Down ENTER Up Down ENTER ENTE...

Page 14: ...T LINE3 GOBO2 FOCUS ZOOM ERROR RESET CIRCUIT LINE4 EFFECTS IRIS ERROR MAGENTA POSITION ERROR CYAN POSITION ERROR YELLOW POSITION ERROR GOBO1 POSITION ERROR GOBO1 INDEX POSITION ERROR COLOUR WHEEL POSI...

Page 15: ...Up Down ENTER Up Down COLOR ALIGNMENT To align color wheel ES ENTER Up Down ENTER Up Down SHUTTER ALIGNMENT To align shutter ES ENTER Up Down ENTER Up Down FOCUSALIGNMENT To align focus ES ENTER 10 HI...

Page 16: ...TER Up Down EFFECTS INDEX ALIGNMENT To align effects wheel index ES ENTER Up Down ENTER Up Down IRIS ALIGNMENT To align iris ES ENTER Up Down ENTER Up Down CYAN ALIGNMENT To align cyan ES ENTER Up Dow...

Page 17: ...t gobos should be made of either heat resistant glass or metal An ever increasing range of gobos is available from your D T S sales network Gobo dimensions are as follows external 37 mm of image with...

Page 18: ...eformation due to heat This will help to avoid the danger of the lamp exploding Mechanical parts Periodically check all mechanical parts gears guides belts etc for wear and tear replacing them if nece...

Page 19: ...1 GOLD Magnetic Sensors Fans 14 CONTROL MOTORS CAR Line 1 Line 1 Brown Line 2 Orange Magenta line 1 BLUE GND ORANGE BROWN VCC J5 FROM J10 PAN TILT YELLOW Display 30 VDC J3 FROM J8 PAN TILT TEMP GND L...

Page 20: ...is line 2 GREY Zoom line 1 LIGHT BLUE Effects Rot Line 2 GOLD Magnetic Sensors J3 FROM J8 PAN TILT FANS 30 VDC Line 1 Line 1 Brown Line 2 Orange Focus line 1 BLUE GND ORANGE BROWN VCC J5 FROM J10 PAN...

Page 21: ...J3 8 MOTORS VIOLET FROM J5 8 MOTORS LIGHT GREEN ENCODER TILT ORANGE ENCODER PAN RED 16 PAN TILT CARD 17 LAMP ON OFF CONTROL CARD FROM J9 8 MOT CONT CARD 1 TO J9 ELECTRONIC BALLAST DATA1 VILOET DATA2...

Page 22: ...S 15 EFFECTS ROTATION 16 FOCUS 17 ZOOM 18 LAMP ON OFF RESET 19 DMX PROTOCOL DMX CHANNEL 1 Parameter PAN msb DMX CHANNEL 2 Parameter PAN lsb DMX CHANNEL 3 Parameter TILT msb DMX CHANNEL 4 Parameter TIL...

Page 23: ...Parameter SHUTTER DMX range Value Mid point DMX value Move range degrees Mode Option Function 0 19 Black out 20 39 Open 60 79 Strobe speed 1 min 80 89 Strobe speed 2 100 109 Strobe speed 3 110 119 Str...

Page 24: ...234 233 Left rotation speed 2 235 237 236 Left rotation speed 3 238 240 239 Left rotation speed 4 241 243 242 Left rotation speed 5 244 246 245 Left rotation speed 6 247 249 248 Left rotation speed 7...

Page 25: ...1 ROTATION INDEX DMX range Value Mid point DMX value Move range degrees Mode Option Function 0 127 Index 0 360 128 185 Left rotation from fast to slow 186 197 Stop 198 255 Right rotation from slow to...

Page 26: ...Parameter GOBO 2 ROTATION INDEX DMX range Value Mid point DMX value Move range degrees Mode Option Function Iris closing combined with Zoom at different speed from Min to Max Iris openig combined with...

Page 27: ...oint DMX value Move range degrees Mode Option Function 0 255 Linear Zoom DMX range Value Mid point DMX value Move range degrees Mode Option Function DMX CHANNEL 18 Parameter RESET 0 9 No Effect 10 60...

Page 28: ...bit 23 GOBO 2 SHAKE 24 IRIS 25 IRIS MACROS 26 EFFECTS 27 EFFECTS ROTATION 28 FOCUS 29 ZOOM 30 LAMP ON OFF RESET DMX CHANNEL 1 Parameter PAN msb DMX CHANNEL 2 Parameter PAN lsb DMX CHANNEL 3 Parameter...

Page 29: ...peed 1 min 160 169 Pulse open speed 2 170 179 Pulse open speed 3 180 189 Pulse open speed 4 max 190 199 Pulse closed speed 1 min 200 209 Pulse closed speed 2 210 219 Pulse closed speed 3 220 227 Pulse...

Page 30: ...ur No Colour IF CHANNEL 9 RAINBOW Dmx range value 192 255 0 9 10 127 Right Rot Speed from Max to Min No Colour 128 137 138 255 Left Rot speed from Min to Max Stop DMX CHANNEL 9 Parameter COLOUR MODE D...

Page 31: ...er GOBO 1 DMX range Value Mid point DMX value Move range degrees Mode Option Function 0 29 15 Open 30 59 45 Gobo 1 60 89 75 Gobo 2 90 119 105 Gobo 3 120 149 135 Gobo 4 150 179 165 Gobo 5 180 207 168 G...

Page 32: ...MX CHANNEL 18 Parameter GOBO 1 SHAKE DMX range Value Mid point DMX value Move range degrees Mode Option Function Stop 0 9 10 22 23 35 36 48 Gobo Shake R L Speed 1 Min Gobo Shake R L Speed 2 Gobo Shake...

Page 33: ...L 20 Parameter GOBO 2 MODE DMX range Value Mid point DMX value Move range degrees Mode Option Function 0 127 Gobo Rotation Mode 128 255 Gobo Index Mode DMX CHANNEL 21 Parameter GOBO 2 ROTATION GOBO 2...

Page 34: ...6 Gobo Shake L R Speed 7 Gobo Shake L R Speed 8 152 164 165 177 178 190 191 203 204 216 217 229 230 242 243 255 Gobo Shake L R Speed 9 Max DMX CHANNEL 24 Parameter IRIS DMX range Value Mid point DMX...

Page 35: ...rotation from Min to Max 181 202 203 255 Stop DMX CHANNEL 28 Parameter FOCUS DMX range Value Mid point DMX value Move range degrees Mode Option Function 0 255 Linear Focus DMX CHANNEL 29 Parameter ZOO...

Page 36: ...without prior written consent from D T S D T S reserves the right to make any aesthetic functional or design modifications to any of its products without prior notice D T S assumes no responsibility f...