DTS SLICE Distributor User Manual Download Page 11

SLICE Distributor 

User’s Manual 

February 2018 

 
 

 
 

support.dtsweb.com

 

11

 

13000-30030-MAN (Rev. 3)

 

Appendix A:  Connector Information 

 

AUX connector 

SYS connector 

 

(pin 12 plugged) 

(pin 8 plugged) 

 

 

 

 

(looking into the connector) 

(looking into the connector) 

Pin 

Function 

 

Pin 

Function 

/PWR_ON (contact closure to ground) 

 

/PWR_ON (contact closure to ground) 

-Event, isolated, bi-directional, 
contact closure to pin 3 

 

-Event, isolated, bi-directional, 
contact closure to pin 3 

+Event, isolated, bi-directional, 
contact closure to pin 2 

 

+Event, isolated, bi-directional, 
contact closure to pin 2 

Recording status (high = recording) 

 

Recording status (high = recording) 

Reserved 

 

ON status 

-VDC input from ext battery/Ground 

 

Ground 

-VDC input from ext battery/Ground 

 

Ground 

Reserved 

 

No connection 

Start record input (apply 5 V with 
respect to ground) 

 

Start record input (apply 5 V with 
respect to ground) 

10 

+VDC input from external battery 

 

10 

9-18 VDC in 

11 

Ground 

 

11 

Ground 

12 

No connection 

 

12 

Ethernet Tx+ 

13 

Reserved 

 

13 

Ethernet Rx+ 

14 

+VDC input from external battery 

 

14 

9-18 VDC in 

15 

Reserved 

 

15 

Ethernet Tx- 

16 

Start record input, contact closure to 
ground 

 

16 

Ethernet Rx- 

 

10 

13 

14 

16 

10 

13 

14 

16 

Summary of Contents for SLICE Distributor

Page 1: ...13000 30030 MAN Rev 3 Diversified Technical Systems Inc All Rights Reserved SLICE Distributor User s Manual February 2018...

Page 2: ...6 SLICE System Connectors 6 Basic Care and Handling 7 Shock Rating 7 Mounting Considerations 7 Thermal Considerations 7 Power Management 8 Maximum Power Consumption 8 Maximum Input Power 8 Maximum Out...

Page 3: ...rience to help via telephone e mail or on site visits The best way to contact a DTS support engineer is to submit a request through the DTS Help Center web portal support dtsweb com You must be regist...

Page 4: ...vercurrent protection power input polarity protection LED indicator provides status information Integral mounting holes Ideal for embedded and in dummy high channel count applications SLICEDistributor...

Page 5: ...s overvoltage or overcurrent condition is present If unit is on cycle power to reset On Off Pushbutton Switch A momentary pushbutton switch is used for on off control When the unit is on LED is blue a...

Page 6: ...for the DAS One SLICE connector supports up to 3 SLICE stacks with a maximum of 8 SLICE Bridges per stack in any combination of SLICE MICRO or NANO SLICE MICRO Accel and ARS units can be used in plac...

Page 7: ...r repair Shock Rating The SLICE Distributor is rated for 500 g 4 ms half sine duration in all axes Mounting Considerations The unit should be securely bolted to the test article or dynamic testing dev...

Page 8: ...utput power available per SLICE system connector is 12 V at 4 A The maximum output current available via the AUX connector is 2 5 A input VDC output VDC Charging Powering Attached Equipment When suffi...

Page 9: ...est fixture to confirm resistance readings of 1 ohm TroubleshootingBasics Begin troubleshooting by checking the operational state of the SLICE Distributor alone DTS suggests always using the connectio...

Page 10: ...lth If the status LED is red this can mean input voltage is too high or overcurrent condition is present You will need to correct this before proceeding 4 Connect the Ethernet comm cable from the SYS...

Page 11: ...to pin 2 3 Event isolated bi directional contact closure to pin 2 4 Recording status high recording 4 Recording status high recording 5 Reserved 5 ON status 6 VDC input from ext battery Ground 6 Groun...

Page 12: ...into the connector Pin Function 1 ON bi directional contact closure input to ground 2 START bi directional contact closure input to ground 3 EVENT bi directional contact closure input to ground 4 Stat...

Page 13: ...Cable SLICE Distributor to DDX cable SDX 1 m 13000 30440 SLICE Distributor AUX Connector Assy 13000 30441 SLICE Distributor AUX Cable Assy 5 m pigtail term 13000 30450 SLICE Distributor SYS Connector...

Page 14: ...0 SD00200 SD00300 x 101 for S Ns SD00101 SD00201 SD00301 x 2 99 for S Ns SD00102 SD00399 Netmask 255 255 252 0 The calibration data for your equipment identifies the IP address as shipped from the fac...

Page 15: ...urrent IP address Use compatibility mode with Internet Explorer Enter the desired IP address and or netmask into the available fields and click Apply If the IP address is valid the page will show succ...

Page 16: ...number of stacks was 4 now 3 referenced in second paragraph and illustrations on page 6 Updated network info to refer to Appendix C Rev 3 27 Feb 2017 EK Added Appendix C and page 8 footnote Updated a...

Reviews: