12- SERVICE MENU
For technical personnel only
To operate this menu:
-Connect the unit to the main
-While reset is running, press the MENU and ENTER keys at the same time.
Up-Down
ENTER
ENTER
ENTER
Up-Down
ENTER
.
ENTER
Up-Down
ENTER
.
ENTER
Up-Down
ENTER
.
ENTER
Up-Down
ENTER
.
ENTER
Up-Down
ENTER
.
ENTER
Up-Down
ENTER
.
ENTER
CURRENT
From min 20 mA to max 600 mA
Default = 300 mA
LENS
PC or Fresnel
lens selection
ZERO OFFSET
From min 1 mm to max 50 mm
Default = 5 mm
RANGE
From min 30 mm to max 150 mm
Default = 103 mm
SPEED
Maximum speed
From min 1 mm/s to max 400 mm/s
Default = 20 mm/s
ACCELERATION
Maximum Acceleration/Deceleration
From min 1 mm/s² to max 400 mm/s²
Default = 10 mm/s²
RATIO
Transmission ratio.
From min 10 mm/turn to max 200 mm/turn
Default = 58.2 mm/turn
Up-Down
ENTER
ENTER
PRODUCT
Product model selection
SCENA LED 150 (Default)
or PROFILO LED 150
Summary of Contents for Scena LED 150