19
PS2801C
[Type A]
+ ー
external power supply
DC+12 to 24V
R
DOVCC
DOCOM
voltage
conversion
R
R
R
1.5K
PS2805C
DIVCC
HW RST
EXT1/EXT2
CLR
STEP/START
Digital I/O IN1 to 10
+ ー
external
power supply
DC+12 to
24V
Relay
[Type B]
5.6K
Load
Pass
Error
Run
Digital I/O OUT
*
[Connection of output signal]
Use it by connecting to devices controlled by current drive, such as relay control or LED.
You can also use it by connecting to devices for current sink output like [Type B].
[Connection of input signal]
Use it by connecting to devices which can be controlled by current drive, like devices having a switch
or transistor output.