background image

HORUS

WIRING DIAGRAMS

HORUS

 is provided with 8 poles plug-in screw ter cable length 1 m (HORUS all models)

  

ACCESSORIES

• Lenses set Spot (HORUS FULL COLOUR) (Code 03.LK.066)
• Lenses set Medium flood (HORUS FULL COLOUR) (Code 03.LK.067)
• Lenses set Wide flood (HORUS FULL COLOUR) (Code 03.LK.068)
• Lenses set Spot (HORUS RGBA / WHITE+AMBER) (Code 03.LK.024)
• Lenses set Medium flood (HORUS RGBA / WHITE+AMBER) (Code 03.LK.025)
• Lenses set Wide flood (HORUS RGBA / WHITE+AMBER) (Code 03.LK.026)
• Z1 PLUS IP20 Power supply / LED controller (Code 03.LA.009.P)
• Z8 IP20 Power supply / LED controller plug-in screw terminals outputs (Code 03.LA.080.V2)
• Z-LIGHT range on-off power supplies also available 

IMPORTANT SAFETY INFORMATION

Fire prevention:

Never locate the fixture on any flammable surface.
Minimum distance from flammable materials: 10 cm

Safety:

The external surface of the unit may exceed 50°C, never handle the unit until at least 5 minutes 
have elapsed since the unit was turned off.
Never install the unit in an enclosed area lacking sufficient air flow.
The ambient temperature should not exceed 40°C and should not be lower than -10°C.

Pin 1 = RED +
Pin 2 = RED -
Pin 3 = GREEN +
Pin 4 = GREEN -
Pin 5 = BLUE +
Pin 6 = BLUE -
Pin 7 = AMBER +
Pin 8 = AMBER -

The maximum distance between Z1 PLUS IP20 Power supply / LED controller and the HORUS LED 
PROJECTOR (all models) should not exceed 100 meters.
The maximum distance between Z8 IP20 Power supply / LED controller and the HORUS

HORUS

 should not exceed 100 meters.

The maximum distance between Z8 IP20 Power supply / LED controller and the HORUS

should not exceed 50 meters.

 

WHITE+AMBER, 

 RGBA

 FULL 

COLOUR 

8 poles plug-in screw terminals

on board (HORUS all models)

 

 

4

1---------PIN---------8

Summary of Contents for HORUS FULL COLOUR

Page 1: ...GB Made in Italy HORUS User s Manual rel 1 0 D T S Illuminazione s r l ITALY http www dts lighting it HORUS FULL COLOUR HORUS RGBA HORUS WHITE AMBER...

Page 2: ...ducts or circuits described herein Les informations contenues dans le pr sent manuel ont t r dig es et contr l es avec le plus grand soin Nous d clinons toutefois toute responsabilit en cas d ventuell...

Page 3: ...6 36 x 1W P4 LEDs 24 x White 12 x Amber HORUS WHITE AMBER 54 54 x 1W P4 LEDs 42 x White 12 x Amber HORUS WHITE 3200 K 48 x 3200 K White LEDs HORUS WHITE 4500 K 48 x 4500 K White LEDs HORUS WHITE 6000...

Page 4: ...ure on any flammable surface Minimum distance from flammable materials 10 cm Safety The external surface of the unit may exceed 50 C never handle the unit until at least 5 minutes have elapsed since t...

Page 5: ...etween Z1 PLUS IP20 Power supply LED controller and the HORUS LED PROJECTOR all models should not exceed 100 meters Never plug in a HORUS LED PROJECTOR when the power supply is turned on 5 R 1 R 2 G O...

Page 6: ...eed 100 meters The maximum distance between Z8 IP20 Power supply LED controller and the HORUS should not exceed 50 meters Never plug in a HORUS LED PROJECTOR when the power supply is turned on WHITE A...

Page 7: ...RECESSED INSTALLATION 7 HORUS FIXING SPRINGS...

Page 8: ...hite finish 03 LDB096 03 W40 HORUS ADJ WA 36LED WIDE flood lenses White finish 03 LDB097 03 T10 HORUS FIX RGB 36LED SPOT lenses White finish 03 LDB097 03 T25 HORUS FIX RGB 36LED MEDIUM flood lenses Wh...

Page 9: ...9 HORUS NOTES...

Page 10: ...10 HORUS NOTES...

Page 11: ...11 HORUS NOTES...

Page 12: ...ic functional or design modifications to any of its products without prior notice D T S assumes no responsibility for the use or application of the products or circuits described herein D T S Illumina...

Reviews: