background image

GB

User’s Manual rel 1.0

D.T.S. Illuminazione s.r.l. - ITALY 
http://www.dts-lighting.it

 

FOS 100 WHITE 36

FOS 100 WHITE 36

FOS 100 SOLO ON-OFF WHITE 36

Made in Italy

FOS 100 SOLO WHITE 36

Summary of Contents for FOS 100 SOLO ON-OFF WHITE 36

Page 1: ...GB User s Manual rel 1 0 D T S Illuminazione s r l ITALY http www dts lighting it FOS 100 WHITE 36 FOS 100 WHITE 36 FOS 100 SOLO ON OFF WHITE 36 Made in Italy FOS 100 SOLO WHITE 36...

Page 2: ...or circuits described herein Les informations contenues dans le pr sent manuel ont t r dig es et contr l es avec le plus grand soin Nous d clinons toutefois toute responsabilit en cas d ventuelles in...

Page 3: ...ent ground connection 3 GENERAL WARRANTY CONDITIONS The unit is guaranteed for 36 months from the date of purchase against manufacturing material defects THIS SYMBOL INDICATES A HOT SURFACE THIS SYMBO...

Page 4: ...012E11WB10 FOS 100 WHITE 36 3000K Narrow lenses Black 03 LBB012E11WB25 FOS 100 WHITE 36 3000K Medium flood lenses Black 03 LBB012E11WB40 FOS 100 WHITE 36 3000K Wide flood lenses Black 03 LBB012E11WBE3...

Page 5: ...Dimensions FOS 100 WHITE 36 4...

Page 6: ...3000K Medium flood lenses Black 03 LBB001S11WB40 FOS 100 SOLO ON OFF WHITE 36 3000K Wide flood lenses Black 03 LBB001S11WBE3 FOS 100 SOLO ON OFF WHITE 36 3000K 15 x 40 lenses Black 03 LBB001S11WB02 F...

Page 7: ...Dimensions FOS 100 WHITE 36 6...

Page 8: ...panel connectors IN OUT DMX XLR 5 poles Male Female panel connectors IN OUT Power supply Z10 IP20 LED PSU Electronic full range 90 260 Vac 50 60 Hz Power consumption 54W Max Operating ambient tempera...

Page 9: ...Dimensions FOS 100 WHITE 36 8...

Page 10: ...male panel connector OUT DMX HARTING 4 poles Male Female panel connectors IN OUT Power supply Z10 IP65 LED PSU Electronic full range 90 260 Vac 50 60 Hz Power consumption 54W Max Operating ambient tem...

Page 11: ...Dimensions FOS 100 WHITE 36 10...

Page 12: ...various points may exceed 50 C Never handle the unit until at least 5 minutes have elapsed since the unit was turned off Never install the fixture in an enclosed area lacking sufficient air flow The a...

Page 13: ...TE 36 FOS 100 WHITE 36 is provided with a 2 poles cable FOS 100 SOLO ON OFF WHITE 36 Brown L Blue N Yellow Green GND MAINS INPUT 90 260Vac 50 60Hz FOS 100 SOLO ON OFF WHITE 36 is provided with a Mains...

Page 14: ...tor DMX IN XLR 5 poles male panel connector DMX OUT XLR 5 poles female panel connector FOS 100 SOLO IP65 WHITE 36 on request LED OUT MAINS INPUT 3 x 1 5 sq mm cable with cable gland MAINS OUTPUT HARTI...

Page 15: ...plugged into the last unit DMX out panel connector of the DMX line Ensure that the conductors do not touch each other Do not connect the cable ground to the DMX connector chassis The plug housing mus...

Page 16: ...lugged into the DMX out panel connector of the last unit connected to the DMX line Ensure that the conductors do not touch each other Do not connect the cable ground to the DMX connector chassis The p...

Page 17: ...will stop flashing and the projector is now controlled by the new DMX address TIPS if you keep pushed the UP or DOWN keys the channels are calculated more quickly and you get a faster selection FOS 10...

Page 18: ...er 0514L007 M4CH mode 5 DMX channels Dimmer RGBW RGBW mode 4 channels 1 DMX channel mode M4CH 5 CHANNELS Up Down Up Down ENTER ENTER Up Down MENU ENTER Up Down REVERSE DISPLAY Reverses display s readi...

Page 19: ...ariation 20 250 ms Smooth response to DMX variation Up Down Up Down ENTER ENTER Linear Linear current output COMPRESSION This menu allows to select between Linear current output or Quadratic current o...

Page 20: ...Up Down Up Down ENTER ENTER Up Down ENTER AUTOMATIC MODE Automatic demo game without DMX controller ChPr Chase with 16 steps previously created in REC MODE Speed and Wait time selectable by user ENTE...

Page 21: ...yed the programmable scenes max 16 scenes from M001 to M0016 DMX channel 12 EDIT channel From 0 19 no function From 20 234 the unit runs the configuration given by the received input DMX values With t...

Page 22: ...Up Down MENU SOFTWARE Software version ENTER TEST MODE RGBW colours test with rainbow Up Down MENU ENTER ENTER Up Down MENU DEFAULT To restore default settings Internal Unit temperature Celsius ENTER...

Page 23: ...ction 0 255 Proportional dimmer DMX CHANNEL 3 Parameter RED first 9 LEDs line DMX range Value Mid point DMX value Move range degrees Mode Option Function 0 255 Proportional colour DMX CHANNEL 1 Parame...

Page 24: ...lor temp Correction Macros 2800K 6500K DMX CHANNEL 7 Parameter PRE PROGRAMME WHITE Useful for FOS FC or CT model Move DMX range Mid point Mode Option Function Value DMX value range degrees 0 55 23 No...

Page 25: ...ro 4 Macro 5 Macro 6 Macro 7 Macro 8 Macro 9 Macro 10 Macro 11 Macro 12 Macro Macro Macro Macro 13 Macro 14 Macro 15 240 255 Macro 16 DMX CHANNEL 8 Parameter CTC Useful for FOS FC or CT model Move DMX...

Page 26: ...247 255 Rainbow Speed 2 5 Sec Rainbow Speed 3 10 Sec Rainbow Speed 4 20 Sec Rainbow Speed 5 30 Sec Rainbow Speed 6 60 Sec Rainbow Speed 7 120 Sec Rainbow Speed 8 180 Sec Random Speed 3 2 Sec Random S...

Page 27: ...constant current LED PSU 1050mA or 1400mA constant current LED PSU LED Red Brown Blue FOS 100 WHITE 36 The maximum number of FOS 100 WHITE 36 connectable to a 1050mA or 1400mA Constant current LED PS...

Page 28: ...ic functional or design modifications to any of its products without prior notice D T S assumes no responsibility for the use or application of the products or circuits described herein D T S Illumina...

Reviews: