background image

The intention of the WEEE Directive
(Directive 2002/96/EC on waste electrical
and electronic equipment) is to reduce the
amount of hazardous substances in waste.
The underlying purpose is to promote the
avoidance, recovery and risk-free disposal
of waste.

VII. Warranty

DTM System checks all the devices before shipping. The
warranty time is 24 months from the selling date. This time
is counted according to the warranty label. The
manufacturer will fix all the problems which come because
of his fault. Non functioning device should be delivered
back to the distributor with short problem description. The
cost of mount/dismount is covered by user. The warranty
do not cover: batteries in the remotes, faults caused by
improper usage, user self repairs and adaptations,
lightning strikes, over voltages or short circuits in the
mains supply. Appropriate legal acts regulates details of
the warranty.

4

VIII. Declaration

2

1

2

VI. Remote TIP and NEO parameters

4
4
4
4
4
4
4
4
4
4

four (two) buttons that can control any channel or the group channels
signal transmission is based on Microchips® KeeLoq® dynamically variable code,
remote frequency 433,92 Mhz
up to 150m radio range NEO, 50m TIP
battery: L1028 23A 12V,
ERP

four (two) buttons that can control any channel or the group channels
signal transmission is based on Microchips® KeeLoq® dynamically variable code,
remote frequency 433,92 Mhz

TIP: 1 mW, NEO: 3 mW;

working temperature from 0°C to +55°C.

2

1

3

4

2

3

4

1

2

2

1

2

1

2

fig. 3. TIP and NEO remotes with buttons

7) Receiver's memory formating

To format receiver's memory push and hold simultaneously C1 and C2 buttons. All LED diodes (except green diode)

will blink. Release buttons when LED diodes stop blink (after about 15 seconds). Receiver's memory has been formated.

Remarks! Format is irreversible. All remotes will be removed from receiver's memory and return to factory settings
(C1 and C2 output in monostable mode turn on time 0,5s)

6) Lock / unlock easy remote control registering function

To secure device from unwanted remote registering (aspecial protected customers areas) it is recomended to lock

easy remote registering function.
To lock hold and release button

, red LED diode will light

, yellow LED diode which shows actual working

mode will light. Push and hold next button. After 4 seconds

diode will light (means that easy remote control registering

function is active). Still hold the button. After another 4 seconds of holding

button diode will light (means that easy remote

control registering function is locked). After releasing button, card will memorize settings and lock easy remote control
registering function.
Same procedure to unlock, just release button when

diode light. By default – factory settings, easy remote control

function is unlock.

(C1/C2)

(C1/C2)

C2

C1

C2

Declaration of conformity

Nr

02/2009

Product is compatible with European Directives:

R&TTE 99/5/EC

Bydgoszcz, Poland

01-08-2009

www.dtm.pl

DTM System, ul. Brzeska 7, 85-145 Bydgoszcz

Summary of Contents for ZSP Rival 432

Page 1: ...o enhance radio range use outdoor aerial Outdoor aerial s concentric cable need to be switched toYmarked terminal block and ground marked terminal block 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Rival 432 receiver is one of remote control and access control devices that build ZSP System Basic application of ZSP System is to work with controllers of gate rollers also lightning alarm system direct connection to a...

Page 2: ...trolock electric connection 3 4 5 1 2 6 7 8 39 mm 102 mm Turn on signalling Working mode signallin during programming momentary monostable bistable Power signalling channel 1 channel 2 Programming buttons shield antenna s u p p l y 1 2 V 2 4 V A C D C channel 1 channel 2 o u t p u t 1 o u t p u t 2 electrolock 24V gate controller manual control output STEP BY STEP supply 24V AC DC Rival 432 receiv...

Page 3: ...tton of new remote control c new remote control is registered with same as previous remote configuration Failure in registering may be caused by radio interferences low batteries or lock of easy remote registering function To remove single remote control from receiver s memory push and hold simulataneously output buttons C1 and C2 All of LED diodes except for green LED diode will light During ligh...

Page 4: ...33 92 Mhz TIP 1 mW NEO 3 mW working temperature from 0 C to 55 C 2 1 3 4 2 3 4 1 2 2 1 2 1 2 fig 3 TIP and NEO remotes with buttons 7 Receiver s memory formating To format receiver s memory push and hold simultaneously C1 and C2 buttons All LED diodes except green diode will blink Release buttons when LED diodes stop blink after about 15 seconds Receiver s memory has been formated Remarks Format i...

Reviews: