7.3  Powering a 12V DC Device:

The booster is a power source for all 12V DC accessories that are equipped with a 12V accessory plug. 

1.  Make sure the device to be powered is OFF before inserting the 12V DC accessory plug into the 12V DC 

accessory outlet.

2.  Open the protective cover of the DC power outlet on the front of the booster.

3.  Plug the device into the outlet and turn the device on (if required).

4.  If the device draws more than 15A or has a short circuit, the circuit breaker of the booster will trip and 

disconnect the power to the device. Disconnect the device and the beaker will automatically reset. The 

DC power outlet is wired directly to the internal battery. Extended operation of a 12V device may result in 

excessive battery drain. Recharge immediately after unplugging the device.

7.4  Powering a USB Device:

The booster is a power source for all accessories that are equipped with a USB plug. The USB port provides 

up to 2.1A at 5V DC.

1.  Ensure the battery clips are securely clipped on the storage holders.

2.  Press the USB button on the front of the unit.

3.  Plug the device into the USB port on the front of the unit.

4.  Turn the USB device on.

5.  Reverse these steps when finished using the USB port.

NOTES: The USB port will shut-off automatically after 60 minutes, if no device is connected.  

Extended operation of a USB device may result in excessive battery drain. Recharge the booster immediately 

after unplugging the device.

8. 

FUSE REPLACEMENT

The Portable Power is equipped with an inline fuse, to protect the battery from overload. 

Fuse Specification 

Model DSR5221: Fast blow, DC automotive type, rated 32 V, 300 A (Bussman/Audio Ohm Srl).

Model DSR5222: Fast blow, DC automotive type, rated 32 V, 500 A (Bussman/Audio Ohm Srl).

WARNING

 Keep away from sparks and flame – battery could emit explosive gases.

1. Allow the fuse to cool down completely (approximately 5 minutes).

2. Make sure the switch is in the OFF position and the unit is unplugged from the external charger.

3. Remove the positive (RED) clamp from the storage compartment on the side of the unit  

  and locate the fuse holder. 

4. Open the fuse holder by removing its cover.

5. Using a wrench, remove the first nut and bolt securing the fuse on the positive cable.  

  Repeat the same steps for the second nut and bolt. Remove the open fuse and replace it  

  with a new one of the same type and rating.

6. Tighten the nuts and bolts to secure the fuse, and then replace the cover of the fuse holder.

7. The unit is now ready to use.

9. 

MAINTENANCE INSTRUCTIONS

9.1  Cleaning and user maintenance should not be done by children without supervision.

9.2  Unplug the charger from the booster and the mains power before attempting any maintenance or cleaning.

9.3  Use a dry cloth to wipe all battery corrosion and other dirt or oil from the charger, battery clamps, cords and the 

booster case. Do not use cleaning fluids.

9.4  Ensure that all of the components are in place and in good working condition.

9.5  All other servicing should be performed by qualified service personnel.

9.6  If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified 

persons, in order to avoid a hazard.

10. 

MOVING AND STORAGE INSTRUCTIONS

10.1  Store the booster and charger in an upright position, inside, in a cool, dry place.

10.2  Always make sure the booster is fully charged before storing. When not in use, it is highly recommended to 

leave the booster on charge. 

IMPORTANT

Do not use and/or store the booster in or on any area or surface where damage could occur if 

the internal battery should unexpectedly leak acid.

Summary of Contents for DSR5221

Page 1: ...AND READ BEFORE EACH USE This manual will explain how to use the unit safely and effectively Please read and follow these instructions and precautions carefully MODELS DSR5221 DSR5222 Professional Ba...

Page 2: ...us situation which if not avoided could result in moderate or minor injury to the operator or bystanders Indicates a potentially hazardous situation which if not avoided could result in damage to the...

Page 3: ...NORMAL OPERATION FOR THIS REASON IT IS IMPORTANT THAT YOU FOLLOW THESE INSTRUCTIONS EACH TIME YOU USE THE BOOSTER 1 13 The booster and lead acid battery of the vehicle must be placed in a well ventil...

Page 4: ...ght connections 4 FOLLOW THESE STEPS WHEN CONNECTING THE BOOSTER TO A BATTERY A SPARK NEAR THE BATTERY MAY CAUSE A BATTERY EXPLOSION TO REDUCE THE RISK OF A SPARK NEAR THE BATTERY 4 1 Attach the outpu...

Page 5: ...ry s charge status press the display button on the front of the booster The digital display will show the battery s percent of charge A fully charged battery will read 100 Charge the internal battery...

Page 6: ...and confirm that the green POWER LED on the charger turns on 4 Check that the yellow CHARGING LED in charger starts pulsing slowly to indicate that charge process has started To know status of the cha...

Page 7: ...ype rated 32 V 500 A Bussman Audio Ohm Srl WARNING Keep away from sparks and flame battery could emit explosive gases 1 Allow the fuse to cool down completely approximately 5 minutes 2 Make sure the s...

Page 8: ...eck the battery charge status by pressing the button on the front of the booster See LED Indicators section of this manual Disconnect the 12V device The internal breaker will automatically reset after...

Page 9: ...222 3999002114 14 DISPOSAL INFORMATION 14 1 Internal battery The battery must be removed from the appliance before it is scrapped The appliance must be disconnected from the supply mains before removi...

Page 10: ...dents unauthorized changes or modifications incorrect transport storage or treatment of the Product d In order to exercise this right the Product must be returned complete and in its original state an...

Page 11: ...11...

Page 12: ...12...

Reviews: