background image

         PA system                                                                       Digital Mixer Amplifier 

 7 

 

In case of any failure in the warranty period, please contact service personnel (or distributor) of our 

company for service. The company shall not be made liable for damages due to unauthorized 

dis-assembly or maintenance or service by unauthorized personnel.

 

Packing list 

No. 

List 

Quantity 

MP9306D or MP9312D 

Manual 

Guarantee card 

Certificate 

Power line 

Remote control 

 

                                      

 

Performance 

 

Model 

MP9306U 

MP9312U 

MP9306D 

MP9312D 

Rated Power 

60W 

120W 

60W 

120W 

Speaker Output 

100V 

Sensibility 

MIC 

0.06

±0.015

  VRMS 

Line 

0.3

±20mV)VRMS 

100V-IN 

100 VRMS 

SNR 

MIC 

≥74db(Maximum)

 

AUX

EMC 

≥80dB

Maximum

 

Frequency Response 

80Hz-15kHz

±3dB

 

Distortion 

0.5 % 

Power Supply 

AC220V, 50-60Hz 

 

AC220V, 50-60Hz

DC24V 

Tone 

Bass 

±10dB 

100Hz

 

Treble 

±10dB 

100Hz

 

Power Consumption 

80W 

150W 

80W 

150W 

Size

W×H×L

 

200×190×44mm 

Net Weight 

1.5kg 

Gross Weight 

2kg 

  Technical specifications are subject to change without prior notice. 

Summary of Contents for MP9306D

Page 1: ...Amplifier SIG CLIP PRO 0 10 MIC1 MIC2 AUX1 0 10 AUX2 0 10 BASS 10 10 TREBLE 10 10 MASTER 0 10 ON OFF USB M PRIORITY User s Manual Welcome to use DSPPA public address system For the better use of this product please read this instruction carefully prior to use Guangzhou DSPPA Audio Co Ltd http www dsppatech com ...

Page 2: ... use instructions on system connection instructions on use of product and technical specifications of the network address center Please read this User Manual carefully before connection installation and use and operate in accordance with corresponding instructions in the Manual This symbol on the rear panel indicates matters needing attentions please use or operate the product in accordance with c...

Page 3: ...PRODUCT DESCRIPTION 1 1 1 Features 1 2 APPEARANCE DESCRIPTION 1 2 1 Front panel 1 2 2 Rear panel 3 2 3 Side Panel 4 3 WORKING MODE 4 4 REMOTE CONTROL INSTRUCTIONS 5 1 SAFETY PRECAUTIONS 6 2 Matters needing attention 6 PACKING LIST 7 PERFORMANCE 7 ...

Page 4: ...t With 1 line 100V inputs and 1 line auxiliary inputs With short circuit overload and high temp protection temperature controlled fan Switch to DC 24V power supply mode automatically if AC power failed optional Individual volume control for Mic 1 2 line 1 2 bass treble and master volume control Remote control 2 Appearance Description 2 1 Front panel MP9312U Mixer Amplifier SIG CLIP PRO 0 10 MIC1 M...

Page 5: ...turn clockwise to turn up the treble 7 Master volume adjustment Adjust the level of all signals except EMC turn clockwise to turn up the volume turn counter clockwise to turn down the volume 8 Power switch Press ON to turn on the power press OFF to close the power 9 Signal level indicator SIG 10 Clip Indicator CLIP 11 Protection indicator PRO 12 Display screen 13 USB interface Insert the U disk to...

Page 6: ...tput interface 4 LINE1 MIC2 IN balanced input interface Can connect with microphone or other external audio 5 LINE1 PP MIC2 switcher LINE1 PP MIC2 audio selection switcher can left and right slide to choose AUX1 or MIC2 or phantom power for MIC2 PP switch 6 Priority 100V input interface This interface has the highest output signal 7 Priority input volume adjustment 8 AUX2 input interface 9 Line Ou...

Page 7: ... BLUE will always flash until device and mobile phone pairing success the name is Bluetooth After finishing the pairing the user can play music on the mobile phone With excellent wireless transmission function 3 2 USB mode When the USB access it will be USB mode automatically plug and play 3 3 Line mode In line mode press MODE digital screen will display LINE Heat dissipation vent ...

Page 8: ...ons As shown in the following figure Function key description Mode main function key working mode switch Power switch Play Pause EQ sound effect 0 9 song selection key can be composed of digital channel selection Mute key Last song Next song Vol Vol Single repeat ...

Page 9: ...lled in the device or before any electric connector of the device is disconnected or reconnected In case of any failure of the device please do NOT open the case and repair without permission from a professional personnel to avoid accident or additional damages to the device Please do NOT place any corrosive chemicals near or on the device 2 Matters needing attention Our company provides a three y...

Page 10: ...e card 1 4 Certificate 1 5 Power line 1 6 Remote control 1 Performance Model MP9306U MP9312U MP9306D MP9312D Rated Power 60W 120W 60W 120W Speaker Output 100V Sensibility MIC 0 06 0 015 VRMS Line 0 3 20mV VRMS 100V IN 100 VRMS SNR MIC 74db Maximum AUX EMC 80dB Maximum Frequency Response 80Hz 15kHz 3dB Distortion 0 5 Power Supply AC220V 50 60Hz AC220V 50 60Hz DC24V Tone Bass 10dB 100Hz Treble 10dB ...

Page 11: ...re Please do NOT remove the cover of the equipment otherwise you may get an electric shock Where necessary repair to the equipment should be conducted by qualified professionals All terminals on the device marked with are live and dangerous and should be connected by trained personnel This is connected to power source via the plug and any failure or danger occurs the user can disconnect the device...

Reviews: