WARNING! 

  This device is marked with the international caution symbol.  It is important to read the 

Recommended Operation section of this manual before using this device as it contains important 
information related to product safety. 
 

General Precautions 

 

All insulation of leads connected to output terminals should have at least a 300V rating.   

 

 

Do not use clip leads in the connections used in arrangements employing the VF-500 linear 
amplifier.  They are very dangerous for high-voltage work. 

 

 

Do not place objects on top of or close beside the amplifier during operation.  Adequate 
airflow around the unit is needed to allow heat to dissipate.   

 

Acceptable Load Types 

 

This amplifier is designed to drive capacitive loads only.  Do not use this amplifier to drive 
resistive loads.  The amplifier will only work properly when a capacitive load is connected to 
the output. 

 

 

Never connect an inductive or a resistive load to the unit.  This would cause a short-lived 
high-current pulse at the output and would damage the amplifier unit. 

 

Short Circuit Damage 

 

Although the VF-500 is protected against a short circuit on the output, it is recommended that 
a short circuit condition be avoided.  

 

 

Never connect an "earth ground" lead (e.g., an oscilloscope ground lead) to the center pin of 
the SMA output terminal.  This causes a short-lived high-current pulse and subsequent 
damage to the unit. 

 

 

If the user desires to observe or audit the output signal of the amplifier using a voltage meter 
or an oscilloscope, the user must ensure that the meter or oscilloscope has an input 
impedance of at least 1 MOhm.  Smaller input impedances could damage the amplifier. 

Summary of Contents for VF-500

Page 1: ...Parkway Court Suite 160 Franklin TN 37064 Tel 615 595 6665 Fax 615 595 6610 VF 500 VOLTAGE FOLLOWER LINEAR AMPLIFIER FOR PIEZOELECTRIC CAPACITIVE LOADS USER MANUAL DYNAMIC STRUCTURES AND MATERIALS LL...

Page 2: ...ended AC input connector configured for the available line voltage OPERATINGAND SERVICES PRECAUTIONS Operate the amplifier in an environment free of flammable gases or fumes To ensure that its safety...

Page 3: ...plifier is designed to drive capacitive loads only Do not use this amplifier to drive resistive loads The amplifier will only work properly when a capacitive load is connected to the output Never conn...

Page 4: ...ximum operating range of 30 to 150V piezo devices which have two lead wires output voltage and ground 2 Low voltage piezoelectric materials rated for a maximum operating range of 30 to 200V piezo devi...

Page 5: ...an output voltage range corresponding to the specifications of the customer s load one of the two types discussed in the Intended Use section Attach a standard load i e a piezoelectric actuator with...

Page 6: ...in if fault conditions exist This protection thus protects both the amplifier and the load The VF 500 is equipped with temperature sensors that will protect the circuitry if the internal temperature o...

Page 7: ...or its designated repair facility Freight charges to return equipment or software to DSM are the customer s responsibility DSM will pay freight charges to return the equipment to the customer Warranty...

Page 8: ...2 Consequential or incidental damages such as property damage and incidental expenses 3 Conditions caused by external factors such as abuse misuse inadequate power supply or acts of God Owing to the w...

Reviews: