DSE STORM 2000 User Manual Download Page 2

 

TABLE OF CONTENTS 

 

1. Safety Instructions                                                                                         1 
2. Technical Specifications                                                                                4 
3. How to Control the Unit                                                                                 6 
4. Shape                                                                                                          17 
5. Trouble Shooting                                                                                         18 
6. Fixture Cleaning                                                                                          19 

 

 

STATEMENT 

 

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL 

CAREFULLY BEFORE INSTALLING AND POWERING YOUR STORM 2000 
RGB LED STROBE. 

 

This device has left our premises in absolutely perfect condition. In order 

to maintain this condition and to en-sure a safe operation, it is absolutely 
necessary for the user to follow the safety instructions and warning notes 
written in this manual. 

 

The manufacturer will not accept liability for any resulting damages 

caused by the non-observance of this manual or any unauthorized 
modification to the device. 

 

Please consider that damages caused by manual modifications to the 

device are not subject to warranty. 

 

 

1. Safety Instructions 

Please keep this User Guide for future consultation. If you sell the unit to 

another user, be sure that they also receive this instruction booklet. 

 

 

Dangerous voltage constituting a risk of electric shock is present 
within a unit

.

 

 

Make sure that the available voltage is not higher than stated on the rear 

panel of the fixture. 
     This fixture should be operated only from the type of power source 
indicated on the marking label. If you are not sure of the type of power 
supplied, consult your authorized distributor or local power company. 

Always disconnect the fixture from AC power before cleaning, removing or 

installing the fuses, or any part. 

Summary of Contents for STORM 2000

Page 1: ...STORM 2000 RGB LED STROBE USER MANUAL Please read the instructions carefully before use...

Page 2: ...rvance of this manual or any unauthorized modification to the device Please consider that damages caused by manual modifications to the device are not subject to warranty 1 Safety Instructions Please...

Page 3: ...perature fluctuation e g after transportation DO NOT switch it on immediately The arising condensation water might damage your device Leave the device switched off until it has reached room temperatur...

Page 4: ...revent or reduce the risk of electrical shock or fire DO NOT expose the unit to rain or moisture 2 DO NOT open the unit within five minutes after switching off 3 The housing the lenses or the ultravio...

Page 5: ...pin DMX Input output PowerCon compatible AC power In Out connectors POWER Operating Voltage 220 240VAC 50 60Hz Power Consumption 1500W Max 5A pf 75 LIGHT SOURCE LED 630RGB LEDs 630 white leds 50 000 h...

Page 6: ...hite1 Segment 4 Intensity 0 100 13 Red2 Segment 5 Intensity 0 100 14 Green2 Segment 6 Intensity 0 100 15 Blue2 Segment 7 Intensity 0 100 16 White2 Segment 8 Intensity 0 100 DMX Quick Reference 4 8 Cha...

Page 7: ...with fixture Then jump each subsequent fixture with a properly rated jumper cable WARNING DO NOT POWER LINK MORE THAN 2 FIXTURES IN ONE SINGLE CHAIN ELECTRICALOVERLOAD MAY OCCUR DATA DMX CABLING To li...

Page 8: ...from specialty retailers CAUTION Do not allow contact between the common and the fixture s chassis ground Grounding the common can cause a ground loop and your fixture may perform erratically Test cab...

Page 9: ...above Place a DMX terminator on the output of the final fixture to ensure best communication FIXTURE LINKING MASTER SLAVE MODE 1 Connect the male 3 pin connector side of the DMX cable to the output f...

Page 10: ...dequate ventilation and no flammable surfaces within 2 feet 6 meters of the fixture You can mount the fixture using fixture clamps or with threaded bolt type hardware Always install the included safet...

Page 11: ...he menu items you select from the menu map on page 10 When a menu function is selected the display will show immediately the first available option for the selected menu function To select a menu item...

Page 12: ...ATION DMX Status Value Hold Holds the last DMX values if signal is lost Value Clear Clears the DMX values if signal is lost Display Mode LCD Display ON or Auto OFF Temp Unit CS Celsius degree and Fahr...

Page 13: ...t DMX Mode then press ENTER 4 Use the UP DOWN buttons to select 1 3 4 7 8 16 or 4 8 pixel modes 5 Press ENTER and then press the ESC button until you reach the Address screen Master Slave Mode 1 Disco...

Page 14: ...you can set the fixture to either hold its last received DMX signal values or clear them 1 Press the UP DOWN buttons until you reach Config 2 Push the ENTER button 3 Using the UP DOWN buttons navigate...

Page 15: ...ntensity 0 100 4 000 255 Blue segment Intensity 0 100 5 000 255 White segment Intensity 0 100 6 000 255 Flash duration 0 full on 7 000 255 Strobe rate 0 30Hz 8 000 005 006 042 043 085 086 128 129 171...

Page 16: ...es In Depth 7 Channel Mode Ch VALUE FUNCTION 1 000 255 Master Dimmer 0 100 2 000 255 Red segment Intensity 0 100 3 000 255 Green segment Intensity 0 100 4 000 255 Blue segment Intensity 0 100 5 000 25...

Page 17: ...ment Intensity 0 100 4 000 021 022 255 No Function White Segment Intensity 0 100 DMX Values In Depth 8 Channel Pixel Mode Ch VALUE FUNCTION 1 000 021 022 255 No Function Red Segment 1 Intensity 0 100...

Page 18: ...Rear Connections 1260 pcs Bright LED Locking Knobs Mounting Bracket Durable Cast Aluminum Housing Stand Plate AC Power In AC Power Out Natural Convection Heat Sink Cooling 3 5 Pin DMX512 Out 3 5 Pin...

Page 19: ...circuit C One of the channels is not working well 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition SYMPTOM S...

Page 20: ...rs must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater...

Reviews: