background image

 

Document: 

SD-1A6 E10FD  

Document: 

SD-1A6 E10FD  

Document: 

SD-1A6 E10FD  

Page:

 3 

Page:

 3 

OWNER'S MANUAL

SD-E10FD / FD4 mini PTZ camera AHD

DSE srl - Digital Surveillance Equipment - WWW.DSE.EU

FUNCTION 

PRESET  

FURTHER INFORMATION 

Set address 

September 85 
CALL 60 CALL 

N = address of the camera on the RS485 BUS (1..256) 

Set baud rate 

SET 85 61 
CALL CALL N 

2400 baud N = 1 N = 2 N = 
3 4800 baud 9600 baud 

Set video output 

September 85 
CALL 62 CALL 

N = 1 AHD PAL    

(DVR DSE) 

N = 2 N = 3 TVI AHD 
NTSC PAL    

(DVR HIKVISION) 

N = 4 N = 5 CVI TVI 
NTSC PAL    

(DVR DAHUA) 

N = 6 CVI NTSC 
N = 7 PAL CVBS (DVR COMPOSITE VIDEO) N = 8 CVBS NTSC 

Home Function 

September 85 
CALL 75 CALL 

It sets the automatic function in which the camera automatically returns after a certain time of inactivity. N = 1 N = No HOME 
position Preset 1 2 N = 3 N = 4 1 Autoscan Tour 1 N = 5 Pattern 1

Tempo Home 

September 85 
CALL 76 CALL 

It sets the idle time after which the camera returns to the home set above function. N = 1..60 minutes

IR illuminators Control 

September 85 
CALL 70 CALL 

It sets the power mode of IR illuminators. N = 1 Automatic ignition N = 2 N = 3 Always on 
Always off

illuminators with zoom power to a 
minimum (close) 

September 85 
CALL 71 CALL 

N = 1..10  

illuminators Power Zoom maximum 
(away) 

SET 85 72 
CALL CALL N 

N = 1..10  

Ignition Sensitivity IR illuminators 

September 85 
CALL 73 CALL 

Defines the threshold power of the illuminators N = 1..10 (a lower value corresponds ignition with less brightness) 

left scan limit 

September 92 

As linear SCAN defines the horizontal continuous movement of the camera between two end points with the same 
level of TILT. With this preset you set the left limit of the scan

Right scan limit 

September 93 

With this preset you set the right limit of scan 

speed scan 

September 85 
CALL 77 CALL 

It defines the speed of horizontal scanning N = 1..50  

Start scan 

CALL 99 

With this preset starts the horizontal scan 

Stop scan 

CALL 96 

With this preset stops the horizontal scanning 

Preset Home Tour 

September 85 
CALL 50 CALL 

As TOUR or CRUISE means the sequential display of more preset with a certain residence time on each one. Of the camera 
factory performs the tour between preset from 1 to 10 with a residence time on each preset to 10 seconds. Here you can set a 
different preset start from preset 1 N = Preset start tour  

Preset final tour 

SET 85 51 
CALL CALL N 

Here you can set the preset end of the tour (Factory 10) N = Preset end tour  

Residence time of the tour 

September 85 
CALL 52 CALL 

Here you can set the dwell time of each preset during the tour (10 seconds Factory) N = 1..255 seconds 