OWNER'S MANUAL

RE-RE-BCCxx DCCxx analog and AHD waterproof cameras with IR

DSE srl - Digital Surveillance Equipment - 

WWW.DSE.EU

DSE srl - Digital Surveillance Equipment - 

WWW.DSE.EU

RE-BCCxxx (cylindrical models) 
RE-DCCxxx (spherical models) 

Product description 

This range of analog cameras is realized to satisfy all requirements of video surveillance in both 
indoor and outdoor. The cameras are contained in a casing made of aluminum tin that can be 
installed outdoors without protections and does not fear the rain. The cameras include an infrared 
illuminator for viewing in the dark so as to ensure surveillance 24 hours on 24.

Connections and controls  

Fixing cylindrical cameras 

- Cameras 

Fixing cylindrical cameras 

- Cameras 

cylindrical are equipped with an integrated bracket for wall mounting, specially designed to allow 
the passage of cables inside it and protect them from tampering. The camera is mounted 
generally in the output cables so as not to leave exposed wires. The fixing base has, however, 
also with a slot lateral cable outlet if the cables come in laterally outer raceway. The bracket is 
fastened to the wall or ceiling with the supplied dowels.  

Fixing spherical cameras -

 The spherical cameras are composed from the camera and 

Fixing spherical cameras -

 The spherical cameras are composed from the camera and 

Fixing spherical cameras -

 The spherical cameras are composed from the camera and 

from the mounting base which are screwed to each other. Prior to mounting, unscrew the base of

fixing 

separating it from the camera body. No need for tools typically used to loosen the mounting base 

from the camera body, however, if this proves too tight at the bottom it is possible to help placing 

a rigid rod, for example a screwdriver, between the two outlet eyelets lateral cables placed in the 

base. The fixing base, separate

from 

camera is fixed to the wall or wall with 
dowels 

in 

correspondence 

of the 

hole of cables exit and on 

it 

screws 

subsequently 

the 

body 

camera. 

Before tighten properly orient the viewing angle.  

BNC video output

At the BNC female bayonet 

connecting the video cable that leads 
then to monitor or DVR typically using 
RG59 coaxial cable and BNC 
connector. Yes they can

also 

use twisted pair cables with balun 
converters. 

Jack DC12V

 We must connect a 12VDC power supply stabilized by at least 1000 mA, such 

Jack DC12V

 We must connect a 12VDC power supply stabilized by at least 1000 mA, such 

as RE-AL4S model / C (not inclusive).  

The requested plug is the standard 5.5 mm. Attention to use STABILIZED feeders that provide 
12V in any load condition. The use of a different supply voltage from 12VDC can generate video 
disorders and in the worst cases damage the camera. Beware extension power cables are too 
long or

small section, 

that could 

to introduce 

excessive fall 

species voltage at the time 

IR illuminator ignition. 

Housing connections

 - The video connections and 

Housing connections

 - The video connections and 

power supply must be protected from the weather and housed in special electrical containers. For 
this reason, the cameras are equipped with an integrated cable about 50 cm

length to reach the box which goes arranged nearby. For some camera models are 

available as an optional accessory prolonged mounting bases to hold the connections inside.

Adjust zoom / focus 

- Cameras with 

Adjust zoom / focus 

- Cameras with 

fixed lens (IR up to 20 m.) does not require focus as set at the factory for most applications. The 
adjustable lens cameras are equipped with 2 external screws that allow to adjust the lens focal 
length and the

fire without opening 

the casing of the camera. Acting initially on ZOOM lives and

regular 

the breadth 

the frame 

(Wide / Zoom) 

based on the area to be framed. 

Remember that in most wide angle corresponds inevitably less image detail. Once you defined 
the field of view act on the FOCUS screw to focus perfectly framed area. Recall that each lens 
has its own depth of field to which it is possible to put in focus in a perfect way only a portion of 
the space in front of the camera. Concentrate on the most important area to adjust the focus 
optimally.

 CAUTION:

 The commissioning fire screws have a limit block that avoids to spill the 

optimally.

 CAUTION:

 The commissioning fire screws have a limit block that avoids to spill the 

optimally.

 CAUTION:

 The commissioning fire screws have a limit block that avoids to spill the 

ferrules drive from their home. E 'need not force over the limit switch to avoid damage to the 
adjustment mechanism.  

Adjusting cameras with autofocus zoom 

- The 

Adjusting cameras with autofocus zoom 

- The 

cameras with autofocus zoom does not have a local adjustment screw, as the objective is 
controlled remotely via RS485 serial line. These cameras are equipped with two additional cables 
which must be connected to the RS485 port of the DVR (CABLE BLUE = RS485 + / A CABLE 
BROWN = RS485- / B) via a twisted pair. The communication protocol Pelco D is the standard of 
all our tellecamere. The protocol parameters are factory ADDRESS: 1, SPEED '2400 baud. If you 
install more than one camera of this type to the same bus, each camera must be set to a different 
ID address. E 'can change address and speed in UTC menu of the camera (see below)  

IR Illuminator 

The cameras incorporate within them an infrared illuminator that emanates illumination invisible 
to the human eye, but visible to the camera. The illuminator turns itself on when it gets dark and 
the camera switches alone in night vision mode. The illuminator ignition allows the vision in B / 
N in absolute darkness until its scope lighting.  