Indications
057-231 ISSUE: 2
Page 22 of 30
4.1 STATUS
Condition
LED Designation
OPE
FAULT 1
FAULT 2
Charger Off
Off
Off
Off
Battery not Detected (Battery Detection Mode)
Cable Voltage Drop Alarm
Green
Constant
Red
Flashing
Red
Flashing
Battery Connected (Battery Detection Mode)
Green
Constant
Red
Constant
Red
Constant
Bulk (Boost) Charge in progress
Yellow
Constant
See Below for Fault Conditions
Absorption Charge in progress
Yellow
Flashing
Float Charge in Progress
Green
Constant
Storage Charge in Progress
Green Flashing
4.2 FAULT CONDITIONS
Condition
LED Designation
FAULT 1
FAULT 2
DC Over Volts Warning and Trip
DC Under Volts Warning
Battery Detection Warning
DC Over Current
Battery Reverse Polarity
Short Circuit Protection
Battery Detection Warning
Red
Constant
Off
Input Fuse Failure
AC Under Voltage Warning and Trip
AC Over Volts Warning and Trip
DC Over Current Warning
Red
Flashing
Off
Battery Over Temperature Warning and Trip
Battery Temperature Sensor (PT1000) Fail
Ambient Over Temperature
Off
Red
Constant
Battery Charger Failure
Red
Constant
Red
Flashing
Battery Detection Mode - Battery not detected
Cable Voltage Drop Alarm
Red
Flashing
Red
Flashing