PG9901/PG8901/PG4901

Supervised Wireless PowerG Indoor Siren 

Installation Instructions

Overview

The PGx901 is a fully supervised, 2 way wireless PowerG indoor
siren. Designed for installation in areas where wiring is difficult or
impossible.

Features

• Built-in link quality indicators reduce installation time by 

eliminating the need for the installer to physically approach 
the control panel.

• Multiple sound types: Burglar (between 1400Hz - 3200Hz), 

fire, gas/CO and flood.

• Entry/Exit beep can be enabled via the control panel to sound 

once the user has armed the system and once the user has 
entered the protected area.

• Squawk (beep) sounds can be configured via the control panel 

to indicate alarm system arming (1 squawk) and disarming (2 
squawks) by a wireless key.

• Double Tamper protection sends a tamper alarm to the system 

if the siren front panel is removed or if the siren is removed 
from the wall.

Notes:

 Sounder is activated for a predefined duration according to

local requirements, or until the system is disarmed. The strobe light
operates as described in the HSM2HOST installation manual.

Operation

• Siren and strobe light activate when an identified event 

message is received from the alarm system.

• When the battery voltage is low, a low battery message is sent 

to the alarm system. After message delivery, at least 2 siren 
alarms are possible before the siren is totally inactive.

Device Setup 

Caution!

 To be installed by service persons in non-hazardous loca-

tions only. Risk of explosion if battery is replaced by an incorrect
type. Observe polarity when installing batteries. Dispose of used bat-
teries according to the manufacturer's instructions and according to
local rules and regulations. 

WARNING:

 Batteries are to be replaced by service persons only.

Note:

 To ensure the continued operation of all wireless devices after

performing a system default, a global upload of all wireless pro-
gramming via DLS is recommended before defaulting the system.
After completing the system default, download the wireless pro-
gramming. 

Legend

A. Battery
B. Battery cable
C. Battery connector
D. Enroll button
E. Self test button
F.

For back tamper screw

Installing Battery

1. Loosen cover screw and 

remove  cover.

2. Insert battery pack and 

securely insert the 
battery cable (B) into 
the battery connector 
(C).

Note:

 When manually pro-

gramming wireless devices,
if a device has been pow-
ered up for more than 48
hours it cannot be enrolled
into the system until the
device has been tampered
and restored. When pro-
gramming the panel using
the Quick Enroll procedure
follow the steps detailed in
“Enroll the Device” below

Note: 

After restoring a low battery trouble the system may take

up to 5 minutes to clear the trouble.

Enroll the Device 

To quick enroll:
1. On a keypad press [*] [8] [Installer Code] [804] [000].
2. Press and hold the device enroll button until the LED lights 

steady and then release the enroll button while the LED is still 
lit. A confirmation message then appears on the keypad.

3. Press [*] key to confirm ID.
4. Enter [3 digit siren #]. 
5. Enter [1 digit partition #] for all desired partitions and press [#]. 

If using an LCD keypad you can scroll to the desired partitions 
and press [*] to toggle the partition.

6. On an LCD keypad enter the label by using word library.
To pre-enroll:
1. Remotely configure the unique ID number into the system. For 

more information see the HSM2HOST manual.

2. When on-site, press the device enroll button.

Note: 

If the wireless device has been powered for more then 48 hours

without being enrolled, tamper and restore the device to enroll it.

Local Diagnostics and Placement Test

Before permanently mounting any wireless device it is recom-
mended to mount the device temporarily and perform a Local Diag-
nostics test.
1. Before testing, remove the plastic cover.
2. Press the self-test button once and release it; The red LED will 

switch ON and then OFF, the green LED will switch ON and 
then OFF, the strobe light will switch ON and then OFF and the 
piezo siren will sound to indicating that the siren is fully 
operational.

3. After 2 seconds the LED blinks 3 times indicating the signal 

strength.

The following table indicates the received signal strength.

IMPORTANT! 

Only GOOD or STRONG signal strengths are

acceptable. If you receive a POOR signal from the device, re-locate
it and re-test until a GOOD or STRONG signal is received. 

Note:

 For UL/ULC installations, only STRONG signal levels are

acceptable. After installation verify the product functionality in con-
junction with the compatible receivers HSM2HOST9, HS2LC-
DRF(P)9, HS2ICNRF(P)9 and PG9920.

Note:

 For detailed Placement instructions refer to the control panel

Reference Guide.

Mounting the Device

1. Mark for drilling.
2. Drill 4 holes.
3. Fasten with 4 supplied screws.

Configuration

To enter the wireless configuration section enter [804][551-566].

Specifications

Alarm Sound Level:

 85 dB at 3 m (10 feet)

Frequency Band (MHz):

 CE Listed PG4901: 433MHz; CE/EN

listed PG8901: 868MHz; FCC/IC/UL/ULC listed PG9901: 915MHz

Modulation:

 GFSK

Antenna:

 Built-in antenna

Communication Protocol:

 PowerG

Siren Type:

 One Piezo 109 db min. Sound Pressure Level @ 1m,

1400Hz – 3200 Hz, sweep frequency 7 Hz. 

Battery Type:

 3.6V/14.5A/H Lithium battery (EVE ER34615M/

w200) (not verified by UL/ULC)

Note:

 Use only the above battery.

Note:

 The strobe flashes 5 times and the red LED lights continu-

ously during first battery installation. 

Battery Life Expectancy:

 8 years  (not verified by UL/ULC)

Low Battery Threshold:

 2 V +300 mV negative slope OR 1.2 V

Strobe Light:

 Pulsed @ 1 sec.

Temperature range:

 -10ºC to +55ºC (UL/ULC only verified the

range 0º-49ºC)

Relative Humidity:

 up to max. 93%RH, non-condensing (UL/ULC

only verified up to max 85%RH)

Dimensions (LxWxD):

 161x161x50mm (6-7/16 x 6-7/16 x 1-3/4

in)

Weight (including battery):

 470g (16.5 oz.)

Color:

 White (with transparent lens)

Compatible Receivers

433MHz Band: HSM2HOST4; HS2LCDRF(P)4; HS2ICNRF(P)4; 
PG4920
868MHz Band: HSM2HOST8; HS2LCDRF(P)8; HS2IC-
NRF(P)8;PG8920
912-919MHz Band: HSM2HOST9; HS2LCDRF(P)9; HS2IC-
NRF(P)9; PG9920

Note: 

Only devices operating at 912-919MHz are UL/ULC listed.

Note:

 Only model PG9901 operating in the frequency band 912-

919MHz is UL/ULC listed.

UL/ULC Notes

The PG9901 has been listed by UL/ ULC for Residential Burglary /
Fire applications in accordance to UL 1023/ C1023 Household bur-
glar Alarms system units and UL 985/ULC-S545 Household fire.

Europe: The PG4901 and PG8901 are compliant 
with the RTTE requirements - Directive 1999/5/EC 
of the European Parliament and of the Council of 9 
March 1999. The PG8901 is certified by DNV (DET 

NORSKE VERITAS) to the following standards: EN50131-4, 
EN50131-1 GRADE 2, CLASS II, EN50131-6 Type C. DNV 
(DET NORSKE VERITAS)  has certified only the 868 MHz 
variant of this product. According to EN 50131-1:2006 and 
A1:2009, this equipment can be applied in installed systems up 
to and including Security Grade 2, Environmental Class II. UK: 
The PG8901 is suitable for use in systems installed to conform 
to PD6662:2010 at Grade 2 and environmental class 2. BS8243 
The Power G peripheral devices have two- way communication 
functionality, providing additional benefits as described in the 
technical brochure. This functionality has not been tested to 

comply with the respective technical requirements and should 
therefore be considered outside the scope of the product’s certi-
fication.

FCC COMPLIANCE STATEMENT

WARNING! Changes or modifications to this unit not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in residential installations. This equipment generates uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio and television reception.
However, there is no guarantee that interference will not occur in a particular installation. If this device
does cause such interference, which can be verified by turning the device off and on, the user is encouraged
to eliminate the interference by one or more of the following measures:
– Re-orient or re-locate the receiving antenna.
– Increase the distance between the device and the receiver.
– Connect the device to an outlet on a circuit different from the one that supplies power to the receiver.
– Consult the dealer or an experienced radio/TV technician.
This equipment complies with FCC and IC RF radiation exposure limits set forth for an uncontrolled
environment.
WARNING! To comply with FCC and IC RF exposure compliance requirements, the smoke detector
should be located at a distance of at least 20 cm from all persons during normal operation. The antennas
used for this product must not be co-located or operated in conjunction with any other antenna or
transmitter.This device complies with FCC Rules Part 15 and with Industry Canada licence-exempt RSS
standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference that may be received or that may cause
undesired operation.
IC:160A - PG9901
The term “IC” before the radio certification number only signifies that Industry Canada technical
specifications were met.

Le present appareil est conforme aux CNR d'Industrie Canada appli-
cables aux appareils radio exempts de licence. L'exploitation est
autorisee aux deux conditions suivantes :(1) l'appareil ne doit pas
produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter
tout brouillage radioelectrique subi, meme si le brouillage est sus-
ceptible d'en compromettre le fonctionnement.

PG9901/PG8901/PG4901

Instructions d'installation de la sirène 
d'intérieur sans fil surveillée de la gamme 
PowerG

Vue d'ensemble

Le PGx901 est une sirène d'intérieur entièrement surveillée,
bidirectionnelle, sans fil, de la gamme PowerG. Destiné à une
installation dans les zones où le câblage est difficile, voire
impossible.

Caractéristiques

• Les indicateurs de qualité de liaison intégrés réduisent les 

temps d'installation en supprimant la nécessité de l'installateur 
d'être physiquement à proximité de la centrale.

• Différents types de son : Intrusion (entre 1400 Hz et 3200 Hz), 

incendie, gaz/CO et inondation.

• Le bip sonore d'entrée/sortie peut être activé par 

l'intermédiaire de la centrale pour sonner une fois que 
l'utilisateur a armé le système et une fois qu'il est entré dans la 
zone protégée.

• Les tonalités (bips sonores) peuvent être configurées par 

l'intermédiaire de la centrale pour indiquer l'armement (1 
tonalité) et le désarmement (2 tonalités) du système d'alarme à 
l'aide d'une télécommande.

• La double protection anti-sabotage transmet une alarme de 

sabotage au système si le panneau avant de la sirène est retiré 
ou si la sirène est décrochée du mur.

Remarques :

 L'avertisseur est activé pour une durée prédéfinie

selon les exigences locales ou jusqu'à ce que le système soit
désarmé. La lampe stroboscopique fonctionne comme décrit dans le
manuel d'installation HSM2HOST.
Fonctionnement

• La sirène et la lampe stroboscopique se déclenchent quand un 

message d'événement identifié est reçu depuis le système 
d'alarme.

• Quand la tension de batterie est faible, un message de niveau 

batterie de pile est transmis au système d'alarme. Après la 
transmission du message, au moins 2 alarmes de la sirène sont 
possibles avant que la sirène ne devienne complètement 
inactive.

Réglage du dispositif 

Attention !

 À faire installer par un agent de service dans des zones

non dangereuses uniquement. Risque d'explosion si la pile n'est pas
du type correct. Respecter les polarités lors de l'installation des piles.
Éliminer les piles usagées selon les recommandations du fabricant,
les lois et réglementations locales. 

AVERTISSEMENT!

 Les piles doivent être remplacées

uniquement par un agent de service.

Remarque :

 Pour garantir le fonctionnement continu de tous les

dispositifs sans fil après avoir réalisé une réinitialisation aux valeurs
par défaut, un téléchargement général de toute la programmation
sans fil par DLS est recommandé avant de réinitialiser le système.
Après avoir complété la réinitialisation aux valeurs par défaut du
système, téléchargez la programmation sans fil.

Légende

A. Batterie
B. Câble de pile
C. Connecteur de la 

batterie

D. Bouton 

d'attribution

E. Bouton 

d'autodiagnostic

F.

Vis du contact 
arrière anti-
sabotage

Installation de 
la batterie

1. Desserrez la vis du 

couvercle et retirez le 
couvercle.

2. Insérez le bloc-piles 

et insérez 
soigneusement le 
câble de pile (B) dans 
le connecteur de 
pile (C).

Remarque :

 Quand vous programmez manuellement les dispositifs

sans fil, si un dispositif a été alimenté pendant plus de 48 heures, il
ne peut pas être attribué dans le système tant que le dispositif n'a pas
été saboté et rétabli.

Remarque: 

Après la restauration d'un défaut de batterie faible,

le système peut prendre jusqu'à 5 minutes pour que la peine.

Attribuez le dispositif dans le système

Pour une attribution rapide :
1. Sur le pavé numérique, appuyez sur [*] [8] [Code de 

l'installateur] [804] [000].

2. Appuyez de façon prolongée sur le bouton d'attribution du 

dispositif tant que le voyant lumineux reste allumé, puis 
relâchez- le bouton d'attribution alors que le voyant lumineux 
est encore allumé. Un message de confirmation apparaît alors 
sur le pavé numérique.

3. Appuyez sur la touche [*] pour confirmer le ID.
4. Entrez le [3 sirène chiffres #].
5. Entrez le [n° de partition à 1 chiffre] pour toutes les partitions 

souhaitées et appuyez sur [#]. Si vous utilisez un pavé 
numérique à cristaux liquides LCD, vous pouvez faire défiler 
les partitions souhaitées et appuyer sur [*] pour basculer la 
partition.

6. Sur un pavé numérique LCD, entrez la référence en utilisant la 

bibliothèque de mot.

Pour une attribution préalable :
1. Configurez à distance le numéro ID unique dans le système. Pour 

plus d'informations, consultez le manuel HSM2HOST.

2. Sur site, appuyez sur le bouton d'attribution du dispositif.

Remarque :

 Si le dispositif sans fil a été alimenté pendant plus de

48 heures sans être attribué, sabotez et rétablissez le dispositif pour
l'attribuer.

Diagnostics locaux et test de positionnement

Avant de fixer de façon permanente un dispositif sans fil
quelconque, il est conseillé de le monter temporairement et
d'effectuer un test de diagnostic local.
1. Avant de tester, retirez le cache en plastique.
2. Appuyez une fois sur le bouton d'autodiagnostic et relâchez. Le 

voyant lumineux rouge s'allume puis s'éteint, le voyant 
lumineux vert s'allume puis s'éteint, la lampe stroboscopique 
s'allume puis s'éteint et la sirène piézoélectrique retentit pour 
signaler qu'elle est entièrement opérationnelle.

3. Au bout de 2 secondes, le voyant clignote 3 fois pour indiquer 

la force du signal.

Le tableau suivant décrit la force de signal reçu.

A

B

C

D

B

E

A

 

1

2

LED response

Reception 

Green LED blinks

STRONG 

Orange LED blinks

GOOD 

Red LED blinks

POOR 

No blinks

No communication

[000]

Partition Assignment

Press the digits of desired assigned partitions.

[001]

Device Toggles

2

F

3

1

(*)

The following are 8-bit toggles
01- Fire - Default [Y]
02- CO - Default [Y]
03- Burg - Default [Y]
04- Flood - Default [Y]
06- Auto Tmp Alarm - Default [N]

[002]

Strobe Alarm - Default [01]

01 - Disabled
02 - Timer Limited
03 - Until Disarmed

[003]

Exit Entry Beeps - Default [01]

01 - Disabled
02 - Enabled
03 - Disabled Stay

[004]

Squawk - Default [02]

01 - Disabled
02 - Sounder Only
03 - Strobe Only
04 - Sounder and Strobe

[001][06]

Sounder Volume - Default [02]

01 - Low
02 - Medium
03 - High

Réponse du voyant

Réception 

Le voyant vert clignote

FORT 

A

B

C

D

B

E

A

 

1

2

D-304681