background image

18

P R O G R A M M I N G  W O R K S H E E T S

[84]

Zone Device Supervision Options (17-24)

Default = ON

Option ON

Option OFF

l________l

Option 1

Zone 17 Supervision enabled

Disabled

l________l

Option 2

Zone 18 Supervision enabled

Disabled

l________l

Option 3

Zone 19 Supervision enabled

Disabled

l________l

Option 4

Zone 20 Supervision enabled

Disabled

l________l

Option 5

Zone 21 Supervision enabled

Disabled

l________l

Option 6

Zone 22 Supervision enabled

Disabled

l________l

Option 7

Zone 23 Supervision enabled

Disabled

l________l

Option 8

Zone 24 Supervision enabled

Disabled

[85]

Zone Device Supervision Options (25-32)

Default = ON

Option ON

Option OFF

l________l

Option 1

Zone 25 Supervision enabled

Disabled

l________l

Option 2

Zone 26 Supervision enabled

Disabled

l________l

Option 3

Zone 27 Supervision enabled

Disabled

l________l

Option 4

Zone 28 Supervision enabled

Disabled

l________l

Option 5

Zone 29 Supervision enabled

Disabled

l________l

Option 6

Zone 30 Supervision enabled

Disabled

l________l

Option 7

Zone 31 Supervision enabled

Disabled

l________l

Option 8

Zone 32 Supervision enabled

Disabled

[90]

Other Options

Default

Option ON

Option OFF

Off

Options 1-6

For Future Use

On

Option 7

RF Jam Detect Disabled RF Jam Detect Enabled

Off

Option 8

Global Placement Test

Individual Placement Test

[91]

Wireless Keys (1-8) Partition Assignments

Default = OFF

Option ON

Option OFF

l________l

Option 1

Wireless Key 01 on partition 2

On partition 1

l________l

Option 2

Wireless Key 02 on partition 2

On partition 1

l________l

Option 3

Wireless Key 03 on partition 2

On partition 1

l________l

Option 4

Wireless Key 04 on partition 2

On partition 1

Summary of Contents for PC5132-433

Page 1: ...lation Manual PC5132 433 NA Version 4 2 W A R N I N G This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer ...

Page 2: ...may not properly alert occupants of a fire for a number of reasons some of which follow The smoke detectors may have been improperly installed or positioned Smoke may not be able to reach the smoke detectors such as when the fire is in a chimney walls or roofs or on the other side of closed doors Smoke detectors may not detect smoke from fires on another level of the residence or building Every fi...

Page 3: ...4 3 4 Identified Wireless Keys 6 Other Programming 7 4 1 Program Zones and Partitions 7 4 2 Enable PC5132 433 Supervision 7 4 3 Enable Supervision of Wireless Zones 8 4 4 Jamming Signal Detection 8 4 5 PC5132 433 Software Default 9 4 6 Deleting Wireless Devices 9 Testing Mounting 10 5 1 Test the Reception of Wireless Devices 10 5 2 Mount the PC5132 433 and Wireless Devices 12 Additional Notes 13 6...

Page 4: ...transmissions are sent every 64 minutes programmable supervisory window can be as long as 24 hours diversity antenna arrangement for better RF reception In addition the PC5132 433 features 6 digit serial numbers for all wireless devices These new serial numbers include hexadecimal digits Please read Section 3 1 A note on Electronic Serial Numbers ESN for more information on enrolling 6 digit devic...

Page 5: ...reless devices follow these steps Refer to the sections listed below 1 Temporarily mount and wire the PC5132 433 module see Section 2 2 Enroll and program wireless devices see Section 3 3 Complete zone and other programming on the system see Section 4 4 Test the placement of all the wireless devices see Section 5 5 Permanently mount the PC5132 433 receiver and wireless devices see Section 5 For ad...

Page 6: ...or Window Contact WLS914 433 Pet Immune PIR WLS909 433 Wireless Key WLS919 433 Wireless Key WLS925L 433 Mini Door Window Contact 1 4 Batteries The wireless devices with the exception of the WLS925L transmitter and the WLS919 433 wireless key are designed to use only Energizer Alkaline batteries by Eveready For the WLS919 433 use only FDK CR2032 type lithium batteries NOTE Do not use other brands o...

Page 7: ...tenna s of the module when it is mounted When mounting the PC5132 433 in a basement place the module as high and as close to the underside of the first floor as possible The range of the module will be reduced if the unit is mounted below ground level 2 3 Installing the Antennas The two antennas must be screwed into the terminals marked ANT1 and ANT2 not GND1 and GND2 Also they must be installed a...

Page 8: ...t serial number 3 2 Enrolling Wireless Devices 1 At a system keypad enter 8 Installer s code to go to the installer s programming section 2 Enter programming section 804 3 Enter the 2 digit number corresponding to the zone the device is to occupy 01 to 32 NOTE Hardwired and wireless devices cannot be assigned to the same zone PC5108 zone expander modules occupy zones in 2 groups of 4 e g zones 9 1...

Page 9: ...ns for the buttons before any keys will work After the functions are programmed when you press and hold one of the four buttons for two seconds the system will execute the programmed function For systems not using partitions program the function buttons in section 59 All wireless keys will have the same four functions For systems using partitions PC5020 PC501X only all wireless keys assigned to Pa...

Page 10: ...Make sure the control panel is v2 0 or higher Program a valid access code for each key Program a closing and opening reporting code for each key s access code Turn off the Quick Arm option in section 015 option 4 of the control panel programming To ensure that an unidentified wireless key cannot disarm the system turn off section 017 option 1 in the control panel programming This option is availab...

Page 11: ...nrolling Wireless Devices To activate module supervision after you enroll the first device s 1 Exit and then re enter installer s programming 2 Enter programming section 902 Wait approximately 1 minute 3 To exit press The system will generate a General System Supervisory trouble if the module is removed from the Keybus If you need to remove the PC5132 433 module from an existing system you will ha...

Page 12: ...ule Programming 3 Enter section 81 4 Enter the time period for the supervisory window The window is programmed in 15 minute increments The default programming is 96 x15minutes which is equal to 24 hours Valid entries are 32 96 equal to 8 24 hours 5 To exit press Disable Enable Zone Supervision All wireless zones have supervision enabled by default To disable supervision for any zone enter the foll...

Page 13: ...32 433 programming to the factory default settings 1 Enter 8 Installer s Code 2 Enter programming section 996 3 Enter the Installer s Code followed by 996 again The software for the PC5132 433 will be restored to its factory default settings 4 To continue programming the unit exit installer s programming by pressing and then re enter installer s programming by entering 8 Installer s Code For instr...

Page 14: ...a 2nd and 3rd test repeat this procedure Carefully replace the backplate onto the detector ensuring that TOP is Carefully replace the backplate onto the detector ensuring that TOP is Carefully replace the backplate onto the detector ensuring that TOP is Carefully replace the backplate onto the detector ensuring that TOP is Carefully replace the backplate onto the detector ensuring that TOP is faci...

Page 15: ...n for the PC5132 8 To exit the placement test and return to installer programming press twice Testing Individual WLS904P 433 WLS906 433 WLS907 433 WLS912 433 WLS914 433 and WLS925L 433 Devices 1 Temporarily place the WLS904P 433 WLS906 433 or WLS925L 433 where you want to mount it 2 At a system keypad enter 8 Installer Code 3 Enter programming section 904 4 Enter the 2 digit zone number for the de...

Page 16: ...2 Mount the cabinet securely to the wall Mount the Devices If you have conducted the placement test described in section 5 1 and got 3 good results in a row for each device you can mount the wireless devices See the Installation Sheet for each device for mounting instructions Now that your PC5132 433 and wireless devices are mounted and working properly read section 6 for information on potential ...

Page 17: ... zone fault 6 2 Jamming Signal Detection The PC5132 433 receiver detects jamming signals that can prevent the receiver from properly receiving transmissions from enrolled devices See section 4 4 Jamming Signal Detection for information on jamming signal detection programming 6 3 Wireless Zone Low Battery Transmission Within any transmission the device will indicate the status of the battery If a b...

Page 18: ...llowing see sections 5 1 and 5 2 for more information on testing devices Verify that you are testing the correct zone Verify that the correct ESN was entered when the device was enrolled Verify that the device is in range of the PC5132 Try testing the device in the same room as the receiver Confirm that the PC5132 433 is properly connected to the Keybus see section 2 for PC5132 433 set up and wiri...

Page 19: ...___l_____l_____l_____l_____l_____l 14 Zone 14 l_____l_____l_____l_____l_____l_____l 15 Zone 15 l_____l_____l_____l_____l_____l_____l 16 Zone 16 l_____l_____l_____l_____l_____l_____l 17 Zone 17 l_____l_____l_____l_____l_____l_____l 18 Zone 18 l_____l_____l_____l_____l_____l_____l 19 Zone 19 l_____l_____l_____l_____l_____l_____l 20 Zone 20 l_____l_____l_____l_____l_____l_____l 21 Zone 21 l_____l____...

Page 20: ...r c s e D y e K n o i t p i r c s e D y e K n o i t p i r c s e D y e K y r t n E y r t n E y r t n E y r t n E y r t n E n o i t p i r c s e D y e K n o i t p i r c s e D y e K n o i t p i r c s e D y e K n o i t p i r c s e D y e K n o i t p i r c s e D y e K 0 00 00 00 00 0 y e K l l u N 6 16 16 16 16 1 t i x E k c i u Q 0 2 0 1 0 2 0 1 0 2 0 1 0 2 0 1 0 2 0 1 0 e s U e r u t u F r o F 7 17 17 ...

Page 21: ...ption 2 Zone 02 Supervision enabled Disabled l________l Option 3 Zone 03 Supervision enabled Disabled l________l Option 4 Zone 04 Supervision enabled Disabled l________l Option 5 Zone 05 Supervision enabled Disabled l________l Option 6 Zone 06 Supervision enabled Disabled l________l Option 7 Zone 07 Supervision enabled Disabled l________l Option 8 Zone 08 Supervision enabled Disabled 83 Zone Devic...

Page 22: ...ion 2 Zone 26 Supervision enabled Disabled l________l Option 3 Zone 27 Supervision enabled Disabled l________l Option 4 Zone 28 Supervision enabled Disabled l________l Option 5 Zone 29 Supervision enabled Disabled l________l Option 6 Zone 30 Supervision enabled Disabled l________l Option 7 Zone 31 Supervision enabled Disabled l________l Option 8 Zone 32 Supervision enabled Disabled 90 Other Option...

Page 23: ...2 Wireless Key 10 on partition 2 On partition 1 l________l Option 3 Wireless Key 11 on partition 2 On partition 1 l________l Option 4 Wireless Key 12 on partition 2 On partition 1 l________l Option 5 Wireless Key 13 on partition 2 On partition 1 l________l Option 6 Wireless Key 14 on partition 2 On partition 1 l________l Option 7 Wireless Key 15 on partition 2 On partition 1 l________l Option 8 Wi...

Page 24: ...indows Rapid air movement around the detector may prevent smoke from entering the unit Do not locate detectors in areas of high humidity Do not locate detectors in areas where the temperature rises above 38o C 100o F or falls below 5o C 41o F Smoke detectors should always be installed in accordance with NFPA 72 the National Fire Alarm Code Smoke detectors should always be located in accordance wit...

Page 25: ... 8 13 K Keybus 3 L location choosing 3 low battery devices 13 M mount devices 11 PC5132 11 N number electronic serial 4 P partition program ming 7 wireless keys 5 placement PC5132 3 test 10 power 3 R removing device 9 module 7 RF jamming 9 S serial number 4 slot number wireless key 5 supervision DEOL 8 device 8 disable 7 module 7 window 8 T testing door window contact 10 global 10 individual 11 mo...

Page 26: ...by failure to provide a suitable installa tion environment for the products damage caused by use of the products for purposes other than those for which it was designed damage from improper maintenance damage arising out of any other abuse mishandling or improper application of the products Digital Security Controls Ltd s liability for failure to repair the product under this warranty after a reas...

Page 27: ... La compagnie de télécommunications peut demander à l utilisateur de débrancher un appareil à la suite de réparations ou de modifications effectuées par l utilisateur ou à cause de mauvais fonctionnement Pour sa propre protection l utilisateur doit s assurer que tous les fils de mise à la terre de la source d énergie électrique les lignes téléphoniques et les canalisations d eau métalliques s il y...

Page 28: ... 2001 Digital Security Controls Ltd Toronto Canada 1 800 387 3630 www dsc com Printed in Canada 29005043 R003 ...

Reviews: