DSC PC5108 Installation Instructions Download Page 2

On control panels with software versions 2.X and lower, the PC5108
v2.0 will operate in two groups of four zones.

For control panels V2.x and lower, please refer to the jumper settings below…

Expander Zones

Jumpers

System Zones Assigned

Group A (Zones 1-4)

J1       J2       J3

Group B (Zones 5-8)

J4       J5       J6

ON

ON

ON

Zones Disabled

OFF

ON

ON

Zones Disabled

ON

OFF

ON

Zones 9 - 12

OFF

OFF

ON

Zones 13 - 16

ON

ON

OFF

Zones 17 - 20

OFF

ON

OFF

Zones 21 - 24

ON

OFF

OFF

Zones 25 - 28

OFF

OFF

OFF

Zones 29 - 32

To Add Hardwired Zones to a Control Panel

1.

Connect module to the Keybus (with the panel powered down).

2.

Set the jumpers on the module.

3.

Power up the system.

4.

Enter section [902] and wait 1 minute.

5.

Enter section [903] to verify that the module is supervised.

6.

Define the zones in sections [002]-[004], [109]-[164] for PC5020.

7.

Add the zones to the appropriate partition in sections [202]-[265].

There is a built-in tamper switch on the expander module located in
the top left corner of the circuit board. If the cabinet in which the
PC5108 Zone Expander is mounted has the hardware required to
depress this tamper switch, DO NOT connect anything to the TAM
terminal.

VAUX

VAUX

VAUX

VAUX

VAUX - Used to provide power for devices. Maximum current draw is not to
exceed 100 mA. Connect the positive lead of powered devices to VAUX and the
negative to BLK or any COM terminal.
KEYBUS

KEYBUS

KEYBUS

KEYBUS

KEYBUS - The 4 wire KEYBUS connection is used by the panel to communicate
with the module. Connect the RED, BLK, YEL and GRN terminals to the KEYBUS
terminals on the PC5010, PC5015 & PC5020 main control.
Z1 to Z8

Z1 to Z8

Z1 to Z8

Z1 to Z8

Z1 to Z8 - Wire the zones according to the description found in the control
panel 

Installation Manual.

Jumper Settings

The PC5108 module can be used to add up to 8 additional hardwired zones to
the PC5010, PC5015, or PC5020 control panel (see 

Installation Manual for

complete installation instructions).

Jumpers

Jumpers are used to determine which zones will be assigned to the expander.

On control panels with software versions 3.X and higher, the PC5108
v2.0 will operate in a single group of eight zones.

For control panels V3.x and higher, please refer to the jumper settings below…

Expander Zones

 Jumpers

System Zones Assigned

Group A (Zones 1-8)

J1

J2

J3

Group B (Not used)

ON

ON

ON

Zones Disabled

OFF

ON

ON

Zones 9 - 16

ON

OFF

ON

Zones 17 - 24

OFF

OFF

ON

Zones 25 - 32

ON

ON

OFF

Zones 33 - 40

OFF

ON

OFF

Zones 41 - 48

ON

OFF

OFF

Zones 49 - 56

OFF

OFF

OFF

Zones 57 - 64

Reviews: