DSC PC5102-433 Installation Manual Download Page 10

P R O G R A M M I N G  W O R K S H E E T S

PC5102 Output Options

Entry

Description

00

Null (No Operation)

01

Main Panel PGM1

02

Main Panel PGM2

03

PC5208 PGM3

04

PC5208 PGM4

05

PC5208 PGM5

06

PC5208 PGM6

07

PC5208 PGM7

[92]

PC5102 PGM1 Output Option

Default 01

Default 01

Default 01

Default 01

Default 01
PGM1 Output Option

l________l ________l

[93]

PC5102 PGM2 Output Option

Default 02

Default 02

Default 02

Default 02

Default 02
PGM2 Output Option

l________l ________l

[94]

PC5102 - PGM1 Output Activation Time

Default 00

Default 00

Default 00

Default 00

Default 00
PGM1 Output Activation Time (Minutes)

l________l ________l

Default 05

Default 05

Default 05

Default 05

Default 05
PGM1 Output Activation Time (Seconds)

l________l ________l

[95]

PC5102 - PGM2 Output Activation Time

Default 00

Default 00

Default 00

Default 00

Default 00
PGM2 Output Activation Time (Minutes)

l________l ________l

Default 05

Default 05

Default 05

Default 05

Default 05
PGM2 Output Activation Time (Seconds)

l________l ________l

NOTE:

  Sections [94] and [95] have a valid minimum programmable value of 00 minutes

01 seconds, and a valid maximum programmable value of 99 minutes 99 seconds.

Partition 8 Wireless Key Options

[68]

Function Key 1

03

l____l____l

Function Key 3

27

l____l____l

Function Key 2

04

l____l____l

Function Key 4

30

l____l____l

Entry

Description

08

PC5208 PGM8

09

PC5208 PGM9

10

PC5208 PGM10

11

PC5204 PGM11

12

PC5204 PGM12

13

PC5204 PGM13

14

PC5204 PGM14

15

PC5102 PGM Pulse (local)

16

PC5102 PGM Toggle (local)

[91]

 

Wireless Keys (1-8) Partition Assignments

Default = 01

Wireless Key 01

l____l____l

Wireless Key 02

l____l____l

Wireless Key 03

l____l____l

Wireless Key 04

l____l____l

Wireless Key 05

l____l____l

Wireless Key 06

l____l____l

Wireless Key 07

l____l____l

Wireless Key 08

l____l____l

firealarmresources.com

Summary of Contents for PC5102-433

Page 1: ... set up the PC5102 433 and wireless keys follow these steps Refer to the sections listed below 1 Temporarily mount and wire the PC5102 433 module see Section 2 2 Enroll and program wireless keys see Section 3 3 Complete PGM and other programming on the system see Section 4 4 Test the placement of all the wireless keys see Section 5 5 Permanently mount the PC5102 433 receiver see Section 5 For addi...

Page 2: ...erminal Descriptions The PC5102 433 has 2 on board relay outputs which can be used in many different applications TheycanbeusedtoactivateLEDs opengaragedoors triggerX 10devicesetc NO1 NC1 COM1 NO2 NC2 COM2 RED BLK YEL GRN NO1 PGM1 Normally Open Relay Contact RED Keybus Power 12V NC1 PGM1 Normally Closed Relay Contact BLK Keybus Ground COM1 PGM1 Relay Common Contact YEL Keybus Clock NO2 PGM2 Normal...

Page 3: ...rmed turn on lights when an alarm occurs and turn them off when disarmed etc Please refer to the control panel Installation Manual for a listing of available output types and their function PGM 1 and or PGM 2 on the PC5102 433 can be set up for this operation see Section 4 1 Section 3 Enrolling Wireless Keys Section 3 Enrolling Wireless Keys Section 3 Enrolling Wireless Keys Section 3 Enrolling Wi...

Page 4: ...fter the functions are programmed when you press and hold one of the four buttons for one second the system will execute the programmed function For systems using partitions PC5020 P 8 PC501X P832 P832DL only All wireless keys assigned to Partition 1 will have the four functions programmed in section 61 All wireless keys assigned to Partition 2 8 will have the four functions programmed in section ...

Page 5: ...keys See section 4 for more information Section 4 Other Programming Section 4 Other Programming Section 4 Other Programming Section 4 Other Programming Section 4 Other Programming 4 1 PC5102 PGM Outputs The PC5102 433 has two on board Form C relay PGM outputs Each of these can be individually programmed to 1 Follow main panel PGM outputs 1 to 14 NOTE Please refer to your System Installation Manual...

Page 6: ...is a quick way to remove all the enrolled wireless keys from the system and reset all the programming in section 804 NOTE NOTE NOTE NOTE NOTE Performing this procedure will not change any programming sections except 804 Resetting the control panel to factory default settings will not return the PC5102 433 module to factory default settings To restore the PC5102 433 programming to the factory defau...

Page 7: ...display the trouble conditions ThefollowingtroubleconditionsapplytothePC5102 433and oranyenrolledwireless keys General System Supervisory This trouble will be generated if the panel loses communication with any module connected to the Keybus The event buffer will log a detailed description of the event Device Low Battery This trouble is generated when a wireless device exhibits a low battery condi...

Page 8: ... the device in the same room as the receiver Confirm that the PC5102 433 is properly connected to the Keybus see section 2 for PC5102 433 setup and wiring instructions Check that you are testing the wireless key correctly see sections 5 1 and 5 2 for testing instructions Check that the batteries are working and installed correctly Look for large metal objects that may be preventing the signal from...

Page 9: ...O d n a m m o C 2 7 t e s e R r o s n e S 0 30 30 30 30 3 m r a l A c i n a P 5 15 15 15 15 1 e s U e r u t u F r o F 1 31 31 31 31 3 e s l u P 1 M G P 2 0 1 5 C P 6 16 16 16 16 1 t i x E k c i u Q 0 2 32 32 32 32 3 e s l u P 2 M G P 2 0 1 5 C P P R O G R A M M I N G W O R K S H E E T S Wireless Key Options Partition 1 Wireless Key Options 61 Function Key 1 03 l____l____l Function Key 3 27 l____l_...

Page 10: ... Default 00 Default 00 Default 00 PGM2 Output Activation Time Minutes l_ _______ l________ l Default 05 Default 05 Default 05 Default 05 Default 05 PGM2 Output Activation Time Seconds l_ _______ l________ l NOTE Sections 94 and 95 have a valid minimum programmable value of 00 minutes 01 seconds and a valid maximum programmable value of 99 minutes 99 seconds Partition 8 Wireless Key Options 68 Func...

Page 11: ...e may be circum stances when there is insufficient warning to allow all occupants to escape in time to avoid injury or death Motion Detectors Motion detectors can only detect motion within the designated areas as shown in their respective installation instructions They cannot discrimi nate between intruders and intended occupants Motion detectors do not provide volumetric area protection They have...

Page 12: ... products damage caused by use of the products for purposes other than those for which it was designed damage from improper maintenance damage arising out of any other abuse mishandling or improper application of the products Digital Security Controls Ltd s liability for failure to repair the product under this warranty after a reason able number of attempts will be limited to a replace ment of th...