30
Keypad Programming
[000] Keypad
Enrollment
(Section 2.5 “Keypad Assignment” on page 4)
NOTE: This must be done at each keypad requiring programming.
[0] Slot [Valid entries are 11-18; i.e. enter [11] for slot 1, [12] for slot 2, etc.]
[1] Function Key 1 Assignment (Valid entries are 00-17)
[2] Function Key 2 Assignment (Valid entries are 00-17)
[3] Function Key 3 Assignment (Valid entries are 00-17)
[4] Function Key 4 Assignment (Valid entries are 00-17)
[5] Function Key 5 Assignment (Valid entries are 00-17)
Function Key Options:
Slot
Function
Function
Function
Function
Function
Key 1
Key 2
Key 3
Key 4
Key 5
LED Defaults
11
03
04
06
14
16
LCD Defaults
18
03
04
06
14
16
KEYPAD 1
I________I________I
I________I
I________I
I________I
I________I
I________I
KEYPAD 2
I________I________I
I________I
I________I
I________I
I________I
I________I
KEYPAD 3
I________I________I
I________I
I________I
I________I
I________I
I________I
KEYPAD 4
I________I________I
I________I
I________I
I________I
I________I
I________I
KEYPAD 5
I________I________I
I________I
I________I
I________I
I________I
I________I
KEYPAD 6
I________I________I
I________I
I________I
I________I
I________I
I________I
KEYPAD 7
I________I________I
I________I
I________I
I________I
I________I
I________I
KEYPAD 8
I________I________I
I________I
I________I
I________I
I________I
I________I
Basic Programming
Zone Definitions
NOTE:Keypads must be installed to use 24-hour Buzzer zones.
NOTE:Keypad zones are assigned in section [020]. Zone Attributes are assigned in sections [101] - [132]. Zone assignment is in
sections [202] - [205].
[001] Zone 1-8 Definitions
(Section 5.2 “Zone Programming” on page 15)
Default
Default
01
I_______I_______I
Zone 1
00
I_______I_______I
Zone 5
03
I_______I_______I
Zone 2
00
I_______I_______I
Zone 6
04
I_______I_______I
Zone 3
00
I_______I_______I
Zone 7
04
I_______I_______I
Zone 4
00
I_______I_______I
Zone 8
00
Null Key
08
[*][1] Bypass Mode
16
[*][0] Quick Exit
01
For future use
09
[*][2] Trouble Display
17
[*][1] Reactivate Stay/Away’s
02
For future use
10
[*][3] Alarm Memory
18
For future use
03
Stay Arm
11
[*][5] User Programming
19
For future use
04
Away Arm
12
[*][6] User Functions
20
For future use
05
[*][9] No-Entry Arm
13
Command Output #1 [*][7][1]
21
For future use
06
[*][4] Chime On / Off
14
Command Output #2 [*][7][2]
07
[*][6][——][4] System Test
15
For future use
00
Null Zone (Not Used)
10
24 Hour Supervisory Buzzer
20
24 Hour Freeze
01
Delay 1
11
24 Hour Burglary
21
24 Hour Latching Tamper
02
Delay 2
12
24 Hour Holdup
22
Momentary Keyswitch Arm
03
Instant
13
24 Hour Gas
23
Maintained Keyswitch Arm
04
Interior
14
24 Hour Heating
24
LINKS Answer
05
Interior, Stay/Away
15
24 Hour Medical
25
Interior Delay
06
Delay, Stay/Away
16
24 Hour Panic
87
Delay 24 Hour Fire (Wireless)
07
Delayed 24 Hour Fire (Hardwired)
17
24 Hour Emergency
88
Standard 24 Hour Fire (Wireless)
08
Standard 24 Hour Fire (Hardwired)
18
24 Hour Sprinkler
09
24 Hour Supervisory
19
24 Hour Water
Summary of Contents for New Classic PC585
Page 4: ...ii PC585 Wiring Diagram ...
Page 51: ......