S e c t i o n 7 : I n s t a l l e r a n d A c c e s s C o d e s
23
S
E
C
T
ION
1
2
3
4
5
6
7
8 9 10 11 12
1
3
1
4
15 16
ter code can only be changed via installer’s program-
ming. (Default = Yes)
•
6 Digit Codes
: If enabled, all access codes will be 6-
digits, except for the panel ID code and Downloading
access code. If disabled, all codes will be 4 digits.
(Default = No)
•
Tbl Req Code
: If enabled, a valid access code must be
entered to silence the trouble beeps from a keypad
(before the condition is restored). If disabled, any key-
press will silence the keypad trouble beeps. (Default =
No)
•
Code Display
: If enabled, access codes will be dis-
played while they are being programmed. If disabled,
access codes digits will be represented by “X.” (Default
= No)
Partition Options
Ref # [0100XX01] where XX = Partition 01-08
The following access code options are programmed by
partition. Only access codes assigned to the selected par-
tition will operate according to the following pro-
grammed items.
•
Bypas Req Code
- If enabled, the user will be required
to enter an access code in order to bypass a zone on
this partition. (Default = Yes)
•
AutoArm Req Cd
- If enabled, the user must enter an
access code during the auto-arm pre-alert period in
order to cancel automatic arming. If disabled, pressing
any key will cancel auto-arming (see section 8.2 “Auto-
matic Arming”. (Default = No)
NOTE:
The Auto Arm Cancellation reporting code, if
programmed, will be sent in either case.
•
Cmd. Out Req Cd
- If enabled, the user will be
required to enter an access code to be able to activate
any output programmed for [*][7][X] Command Out-
put. If disabled, no code will be required. There are
eight toggle options, one for each of the Command
Outputs 1-8. (Default for all = No.)
•
[*][6] Any Code
- If enabled, any access code can be
used to access [*] [6] user functions. If disabled, only a
master code will be able to access these functions.
(Default = No)
7.5 Access Levels
Ref #: [0100XX05] where XX = Partition 01-08
Access levels allow access codes to be active according to
a schedule. Only one access level can be assigned each
user. See the PC4020 Instruction Manual “Access Codes”
for details on access code programming.
Up to 61 access levels can be programmed per partition.
To program an access level, select the access level num-
ber 02-63. Enter the number of the date schedule pro-
grammed for the times and days you wish the access
level to follow (see Section 14.1 “Date Schedules”).
Access level 00 means that the user will never have
access. Access level 01 means that the user will always
have access to a given area.
NOTE
: Always program System Master codes as access
level 01.