background image

6

LINKS2150 Programming Sections

These sections will only be available if a LINKS2150 v1.4W is connected to the Keybus.

[20] Module Configuration

Module configuration is set using Zone Lights as
shown below.  After you enter section [20], the
options that are “on” will be shown either by the
corresponding zone light being on (LED keypads) or
the zone number being displayed (LCD keypads).
Press the corresponding number key to turn an option
ON or OFF. When finished, press [#].

Zone Light 1

ON -

Communications Enabled

 - The

LINKS2150 will initiate communications for
all events that the panel has reporting
codes programmed for.

OFF -

Communications Disabled

 - The

LINKS2150 will not initiate communications
for events that the panel has reporting
codes programmed for.  Disable
communications to test the system.

Zone Light 2

OFF -

TRBL OUT Normally High Impedence

     - If

there are no trouble conditions detected by
the LINKS2150, the TRBL OUT terminal will
be high-impedence. The TRBL OUT
terminal will switch to ground when the
LINKS2150 detects a trouble condition.

ON -

TRBL OUT Normally Low

 - If there are no

trouble conditions detected by the
LINKS2150, the TRBL OUT terminal will be
low (ground). The TRBL OUT terminal will
switch to high-impedence when the
LINKS2150 detects a trouble condition.

Zone Light 3 to Zone Light 8

 - For Future Use

[30]  Call Direction Options

Program which of the following reporting code types
the LINKS2150 will send to the central station. Press
the number corresponding the the appropriate option
to turn the reporting type ON or OFF. When finished,
press [#].

Option

1

Alarm/restore reporting

2

Tamper/restore reporting

3

Opening/closing reporting

4

System maintenance reporting

5

System test transmission reporting

In most installations, you should program the tranmission of
alarm/restore reporting codes only. Your radio network has
limited bandwidth and capacity. The more signals each
LINKS2150 transmits, the fewer LINKS2150s you will be
able to install on your network.

[86] LINKS2150 Programming Sections
for PC1580
or
[803] LINKS2150 Programming Section
for PC5010, PC5015, PC5008, PC1565,
PC1565-2P,  PC585

[01] 2150 Account Code

This 4-digit code is used to identify the system and is
transmitted when the LINKS2150 initiates
communications.  Program a 4 digit code in this
section using only numbers from 0 to 9.

Note:

 An account number must be entered in this

section before communications through the
LINKS2150 can be used.  Do not enter Hexadecimal
numbers in this section.

[10] Maintenance Alarm Reporting Codes

Program 2 digit reporting codes for each of the
following reporting codes

Internal Low Voltage

This code will be sent when the voltage supplied
to the LINKS2150 on the 12+ and 12 - terminals is
less than 10.5 V

DC  

for more than 4 minutes

External AC Trouble

This code will be sent when the AC TRBL input
terminal is switched to ground.

External Low Battery Trouble

This code will be sent when the LB TRBL input
terminal is switched to ground.

Control Panel Connection Trouble

This code will be sent when connection is lost to
the panel on the Keybus for more than 60
seconds

Test Transmission

This code will be sent at the same interval as the
test transmission of the panel.

[11] Maintenance Restoral Reporting Codes

Program 2 digit reporting codes for each of the
following reporting codes

Internal Low Voltage

This code will be sent when the voltage supplied
to the LINKS2150 ion the 12+ and 12 - terminals
is restored to more than 11.6 V

DC 

for more than 4

minutes

External AC Trouble

This code will be sent when the AC TRBL input
terminal is switched to ground.

External Low Battery Trouble

This code will be sent when the LB TRBL input
terminal is switched to ground.

Control Panel Connection Trouble

This code will be sent when connection is
restored to the panel on the Keybus for more
than 60 seconds.

Summary of Contents for LINKS 2150

Page 1: ... Radio Alarm Transmitter Version 1 4W W A R N I N G Please refer to the System Installation Manual for information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer ...

Page 2: ...ller Code 993 Restore LINKS2150 Factory Default Programming for PC5010 v1 1 or later PC5015 PC5008 PC1565 PC1565 2P PC585 5 Hardware Reset 5 FOR THE RECORD 6 LINKS2150 PROGRAMMING WORKSHEETS 7 86 LINKS2150 Programming Sections for PC1580 7 803 LINKS2150 Programming Section for PC5010 PC5015 PC5008 PC1565 PC1565 2P PC585 7 01 RF Identification Code 7 10 Maintenance Alarm Reporting Codes 7 11 Mainte...

Page 3: ...KS cabinet in a convenient location next to the already installed security system control panel cabinet As much as is reasonably possible do not mount the LINKS2150 near sources of interference These include sources of electrical noise such as computers televisions and electric motors in appliances and heating and air conditioning units as well as large metal objects like heating ducts and plumbin...

Page 4: ...y being used has a low battery trouble output connect the output to the LB TRBL terminal When the LB TRBL terminal is shorted to ground the LINKS2150 will transmit the External Low Battery Trouble reporting code programmed in Section 10 OUT TRBL Output Terminal The OUT TRBL output terminal will switch to ground when the LINKS2150 detects a trouble condition The OUT TRBL terminal may be connected t...

Page 5: ...digit displayed enter the new digit If you wish to keep that digit unchanged skip over the digit by pressing the F Key Hexadecimal numbers may also be entered in most sections Refer to Hexadecimal Data Programming for instructions When you are done programing the section enter the 2 digit number of the next section to be programmed Reviewing Programmed Data Enter the 2 digit number of the section ...

Page 6: ...nly Your radio network has limited bandwidth and capacity The more signals each LINKS2150 transmits the fewer LINKS2150s you will be able to install on your network 86 LINKS2150 Programming Sections for PC1580 or 803 LINKS2150 Programming Section for PC5010 PC5015 PC5008 PC1565 PC1565 2P PC585 01 2150 Account Code This 4 digit code is used to identify the system and is transmitted when the LINKS21...

Page 7: ...e will be sent when the LINKS2150 receives a General System Supervisory Restoral event from the PC1580 83 Miscellaneous Alarm Reporting Codes PC1565 v2 0 and PC5008 v2 0 panels only Program 2 digit reporting codes for the following see your Installation Manual for more information Police Code This code will be sent when the LINKS2150 receives a Police Code event from the PC1565 or PC5008 Delinquen...

Page 8: ...____________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ _______...

Page 9: ...ernal AC Trouble Restore I______I______I External Low Battery Trouble Restore I______I______I Control Panel Connection Trouble Restore 20 Module Configuration Default Option Option ON Option OFF ON I______I 1 Communications enabled Communications disabled OFF I______I 2 TRBL OUT Normally Low TRBL OUT Normally High Impedence OFF I______I 3 8 For Future Use 30 Call Direction Options Default Option O...

Page 10: ..._____I General System Supervisory Restore Note Sections 81 and 82 will be for 1580 v1 x only 83 Miscellaneous Alarm Reporting Codes PC1565 and PC5008 v2 0 panels only Default FF I__ _____I_ ______I Police Code I__ _____I_ ______I Delinquency Code 96 Installer Code 96 Restore LINKS2150 Factory Default Programming for PC1580 993 Installer Code 993 Restore LINKS2150 Factory Default Programming for PC...

Page 11: ...11 Hook up Diagram ...

Page 12: ...hase installation or operation or failure of this product WARNING Digital Security Controls Ltd recommends that the entire system be completely tested on a regular basis However despite frequent testing and due to but not limited to criminal tampering or electrical disruption it is possible for this product to fail to perform as expected LIMITED WARRANTY FCC Compliance CAUTION Changes or modificat...