5
2.4 Alarms Displayed While Armed
Option
You can disable the display of alarms on the
keypad when the system is armed. The display of
alarms is enabled by default. To disable the display
of alarms when the system is armed, turn off
section [6], option [5]:
1. Enter [*][8][Installer’s code]
2. Enter [000] to go to keypad programming
3. To turn the display of alarms on or off, enter section
[6].
4. Turn option [5] on or off:
[5]
ON = Alarms not displayed while system is
armed
OFF = Alarms are always displayed while
system is armed
5. When you are finished, press [#] to exit.
2.5 Emergency (Fire, Auxiliary,
Panic) Key Options
You can enable or disable the Fire, Auxiliary and
Panic keys at each keypad. These keys are
enabled by default. Please see your system’s
Installation Manual for more information on these
keys and their options. To turn any of the emer-
gency keys on or off on the keypad:
1. Enter [*][8][Installer’s code]
2. Enter [000] to go to keypad programming
3. Enter section [7].
4. To turn the emergency key options on or off, press
[1], [2], or [3]:
[1]
ON = Fire key enabled
OFF = Fire key disabled
[2]
ON = Auxiliary key enabled
OFF = Auxiliary key disabled
[3]
ON = Panic key enabled
OFF = Panic key disabled
5. When you are finished, press [#] to exit.
2.6 Door Chime Options
You can program the LCD5501Z32-900 keypad to
sound a tone when any zone is opened or closed.
There are two parts to the LCD5501Z32-900 door
chime programming:
• Program if the LCD5501Z32-900 will chime when
zones are opened and/or closed.
• Program the type of sound the LCD5501Z32-900 will
make when an individual zone is opened or closed.
For the door chime feature to work, you will also need
to turn on the Door Chime attribute for each zone that
will trigger the chime. This programming is done in the
control panel software. Refer to your control panel’s
Installation Manual for more information.
Door Chime on Zone Openings/Closings
You can program each LCD5501Z32-900 keypad to
sound a door chime when zones are opened and/or
when they are closed. By default, LCD5501Z32-900
keypads are programmed to sound door chimes on
both zone openings and closings.
To change the door chime opening/closing settings,
at each LCD5501Z32-900 keypad:
1. Enter [*][8][Installer’s code]
2. Enter [000] to go to keypad programming
3. Enter section [6].
4. To turn the options on or off, press [6] or [7]:
[6]
ON =
Door Chime Enabled for Zone
Openings
OFF = Door Chime Disabled for Zone
Openings
[7]
ON =
Door Chime Enabled for Zone
Closings
OFF = Door Chime Disabled for Zone
Closings
5. When you are finished, press [#] to exit.
K E Y P A D P R O G R A M M I N G