Chapter 2.0 Understanding Your Keypad

12. OPEN

This icon is used with clock digits 1 and 2 to indicate activated
zones (not alarm) on the system. When zones are opened, the
OPEN icon will turn on, clock digits 1 and 2 will scroll through
the violated zones.

13. AC

Indicates that AC is present at the main panel.

14. System Trouble

Indicates that a system trouble is active.

15. Night

Indicates that the panel is armedin the Night Mode.

16. Ready Light (green)

If the Ready light is on, the system is ready for arming. If the
toggle of the Ready LED flashes for Force Arming enabled, the
LED flashes with force armable zones open on the partition.

17. Armed Light (red)

If the Armed light is on, the system has been armed successfully.

Note:

For UL listed installations, zones can only be bypassed manually.

2.2 Keypad Models

Note:

In the following list if x = 9 (the system operates in 912-919MHz), x=4 (the system operates

in 433MHz band) or x=8 (the system operates in 868MHz band). Only models operating in 912-
919MHz band are UL/ULC listed.

HS2LCD

Alphanumeric LCD keypad

HS2LCDP

Alphanumeric LCD keypad with Prox. Tag support

HS2ICN

Icon keypad

HS2ICNP

Icon keypad with Prox. Tag support

HS2LED

LED keypad

HS2LCDRFx

Alphanumeric LCD keypad with wireless receiver

HS2LCDRFPx

Alphanumeric LCD keypad with wireless receiver and Prox. tag support

HS2ICNRFx

Icon keypad with wireless receiver

HS2ICNRFPx

Icon keypad with wireless receiver and Prox. tag support

HS2LCDWFx

Wireless Alphanumeric LCD keypad

HS2LCDWFPx

Wireless Alphanumeric LCD keypad with Prox. Tag support

HS2LCDWFPVx

Wireless Alphanumeric LCD keypad with Prox. Tag support & Voice Promp

HS2TCHP

Touchscreen keypad. For additional information, refer to the HS2TCHP
Touchscreen User Manual.

- 6 -

Summary of Contents for HS2016-4

Page 1: ...R code to the right HS2016 HS2016 4 HS2032 HS2064 HS2064 E HS2128 HS2128 E Alarm Panel User Guide WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual should be care fully read ...

Page 2: ...ming Unsetting the System 11 4 7 To Disarm Unset the System with a Proximity Tag 12 4 8 Disarming Error 12 5 0 Emergency Keys 13 6 0 Access Code Types 14 6 1 Opening the Access Code Menu 15 6 2 Adding Changing and Deleting Access Codes 15 6 3 Burglary Verification 15 6 4 Swinger Shutdown 16 6 5 Call Waiting 16 6 6 Fire Alarm Verification 16 6 7 Silence Fire or CO Alarm 16 6 8 System Lockout due to...

Page 3: ... Ready light and the Armed light are both on an Exit Delay is in progress Away Arm Medical Trouble On indicates a system malfunction or tamper Flashing indicates that the keypad has a low battery condition Follow the instructions displayed or enter 2 to view trouble Correcting the trouble turns off the indicator Chime Panic AC Power Indicates AC Power is present The AC Power light will turn off wh...

Page 4: ...Brightness 6 Master Code 1 2 8 8 Change Contrast 6 Master Code 1 3 8 8 Add Delete User 5 Master Code Access Code 1 7 0 Reset Smoke Detect ors OR 7 2 5 2 View Troubles 2 Access Code 8 15 View Alarms 3 Access Code 5 1 5 Perform System Test 6 Master Code 0 4 4 4 Buzzer Volume 6 Master Code 1 4 8 10 4 ...

Page 5: ...hours minutes divider and will flash once per second when the local clock is active 3 Clock Digits 3 4 These are the minute digits when the local clock is active The digits 3 and 4 are used to indicate the zone number for open zones or alarm in memory These two digits combined with the clock digit 2 scroll one zone per second from the lowest number to the highest when scrolling through zones 4 1 t...

Page 6: ...n only be bypassed manually 2 2 Keypad Models Note In the following list if x 9 the system operates in 912 919MHz x 4 the system operates in 433MHz band or x 8 the system operates in 868MHz band Only models operating in 912 919MHz band are UL ULC listed HS2LCD Alphanumeric LCD keypad HS2LCDP Alphanumeric LCD keypad with Prox Tag support HS2ICN Icon keypad HS2ICNP Icon keypad with Prox Tag support ...

Page 7: ...ide the protected premises close to the entry exit door s The security system has several zones of area protection and each of these zones is connected to one or more sensors motion detectors glassbreak detectors door contacts etc A sensor in alarm is indicated by the corresponding zone lights flashing on an LED keypad or by mes sages on the LCD keypad Note Only the installer or service profession...

Reviews: