background image

Mounting

To open the case, remove screw and gently twist the top cover counter-clockwise and
lift it up from the bottom cover. Use a small screwdriver to remove the appropriate
knockouts for wiring. Mount the bottom cover.

To close the case, use the locating line on the bottom cover to align the tab on the top
cover. Once the top cover is engaged, twist the top cover clockwise to lock it in place.
Use screw to attach top cover to the bottom cover.

NOTE: 

Since no adjustment is necessary for the circuit board, it is not recommended

that the installer remove the circuit board from the case.

Device Enrollment

The serial number located on the back of the device must be enrolled into the alarm
control panel via Installer’s Programming ([

] [8] [Installer’s Code]). This procedure is

outlined for the PC4010/4020 in the control panel Installation Manual and for the
Power panels in the PC5100 Installation Manual.

WARNING: Connect only DSC Addressable Series devices to the addressable
loop connections. Connection of ANY other type of device will impair operation.
Any devices other than Addressable Series devices which require power to oper-
ate must be powered separately.

Walk Testing

Once the detector has been set up, walk test the entire area where coverage is
desired. Should the coverage be incomplete, readjust or relocate the detector to
obtain full coverage. 

IMPORTANT NOTE: Upon installation, the unit should be thoroughly tested to
verify proper operation. The end user should be instructed on how to perform
walk tests, and should walk test the detector weekly.

Changing the Sensitivity

AMB-500 features Fast and Slow detection modes, which are set on jumperJ1.
Jumper J1  is set at the factory for the Fast detection mode.  In a normal operating
environment, this setting provides the best detection.

In certain environments where rapid air movement, heaters and other variables
present problems, use Slow detection mode to stabilize the detection.

To change the setting from Fast to Slow, take the jumper off the header.

firealarmresources.com

Summary of Contents for AMB-500

Page 1: ...he number of devices that can be attached to an addressable loop Specifications Current rating 0 75 mA standby 3 mA test mode Operating environment 32 F 120 F 0 C 49 C 5 93 RH non condensing Radiated RF immunity 10 V m with 80 AM over range 80MHz to 1 0GHz Conducted RF immunity 10V with 80 AM over range 150kHz to 100MHz Static immunity 15 kV Transient immunity 2 4 kV 1 2 joules Maximum detection r...

Page 2: ... sunlight directly onto the detector Avoid locations that are subject to direct high air flow such as near an air duct out let Do not locate the detector near sources of moisture steam or oil Do not aim the detector such that it will receive direct or reflected mirror sunlight Do not limit the coverage by large obstructions within the detection area such as plants or filing cabinets Device Wiring ...

Page 3: ...ct only DSC Addressable Series devices to the addressable loop connections Connection of ANY other type of device will impair operation Any devices other than Addressable Series devices which require power to oper ate must be powered separately Walk Testing Once the detector has been set up walk test the entire area where coverage is desired Should the coverage be incomplete readjust or relocate t...

Page 4: ...regoing warranty shall apply only to the original buyer and is and shall be in lieu of any and all other warran ties whether expressed or implied and of all other obligations or liabilities on the part of Digital Security Controls Ltd Digital Security Controls Ltd neither assumes nor authorizes any other person purporting to act on its behalf to modify or to change this warranty nor to assume for ...

Reviews: