background image

TT7000 

– RF Meter / Counter / Generator - User Guide – V3.1 - 2021

www.dsinstruments.com

 

TT7000

Basic Setup and User Guide

 

Device Overview

 

Unit Power-up

 

Notes and Warnings

 

Ports and Controls

 

System Modes

 

Remote Operation

 

PC Applications

 

SCPI Commands

 

Contact Info

    

TT7000 

– Introduction to a Compact Multi-Purpose RF Instrument

 

The TT7000 combines a Microwave Frequency counter, Power Meter, 
Signal Generator, and RF divider in one compact instrument. This 
instrument can either be used as a stand-alone device, or operated from a 
PC via USB. The Frequency Counter and Power meter cover the band from 
100 to 7000MHz. The Signal Generator covers from 300 to 9600MHz.

The TT7000 is very simple to setup and begin to use. Stand-alone usage 
only requires a standard 5 volt USB type-C cable. This can be powered 
from a USB port on a PC, powered USB hub, wall charging adapter, or a 
lithium-ion battery pack. No data connection is needed. Once the device is 
powered, the TT7000 will display the firmware version and model number. 
The TT7000 will then boot up into Meter-Counter Mode and begin 
displaying the detected RF power level and the constant wave frequency.

text

text

 

S

D

Summary of Contents for TT7000

Page 1: ...s a stand alone device or operated from a PC via USB The Frequency Counter and Power meter cover the band from 100 to 7000MHz The Signal Generator covers from 300 to 9600MHz The TT7000 is very simple to setup and begin to use Stand alone usage only requires a standard 5 volt USB type C cable This can be powered from a USB port on a PC powered USB hub wall charging adapter or a lithium ion battery ...

Page 2: ...GUI to manually enter the frequency range of your signal if auto range is not consistent If the power level is too low or there is no signal input the frequency counter display will wonder This is normal functionality The TT7000 requires USB current of up to 1 0 Amps An unpowered USB hub or an excessively long or low quality USB cable will degrade the device performance We recommend a USB 3 0 port...

Page 3: ...uency output 3 Counter Only Mode Displays the counted frequency input in MHz with a longer gate time and more precision in a large font Mode button quick press saves this reading as the power meter CAL frequency 4 Meter Only Mode Displays a more accurate power level in dBm with more averaging and longer refresh rate Up Down buttons set the CAL frequency 5 Signal Generator Mode Displays the frequen...

Page 4: ...dows come with NET and USB drivers pre installed If they are missing or outdated they can both be downloaded from our website Although we do not yet have native control GUIs Linux and Android along with many embedded operating systems have integrated driver support for the TT7000 Typical User Connections for Remote Operation via USB USB Power and Serial Interface Host PC TT7000 RF D S 5895 821 MHz...

Page 5: ... the input signal power level is too low and the counter cannot successfully determine the correct frequency the power meter accuracy will significantly degrade In this case the user should enter a manual calibration frequency The frequency counter gate time and power meter averaging can be adjusted to the user s preference Slower update rates average more readings over a longer time and will resu...

Page 6: ... calibration for the power meter is set to the signal generator frequency The signal generator output control will allow the user to set the frequency power level and power fine tune Power output level is controllable from 300 4800Mhz Band 2 4800 9600MHz is fixed output level and is typically 12dBm TT7000 RF Meter Counter Generator User Guide www dsinstruments com ...

Page 7: ...ne tune knob VERNIER Return the fine power tune setting POWER READ Returns the input power in dBm measured RMS FREQ READ Returns the counted input frequency in MHz SYST MODE METERCOUNTER SIGGENMETER SIGNALGEN Sets the system mode 3 modes SYST MODE Returns the current mode POWER FCAL POWER FCAL 0 POWER FCAL 2333 Forces power meter calibration at this MHz point 0 auto IDN Return the SCPI identificat...

Page 8: ...ort For additional questions suggestions and technical support please contact us DS Instruments Contact Info www dsinstruments com support dsinstruments com TT7000 RF Meter Counter Generator User Guide www dsinstruments com ...