Control:
Designed with SCM control. The motor will cut off when operation exceeds 50s.
Features
Specifications
Power supply
Sensing distance
Warm air temp.
Motor speed
Heating power
Overall unit power
Overall dimension
Appearance
220V~50Hz
12+3cm
25000rpm
700W
1250W
210mmX182mmX270mm(LxWxH)
C
hrom
e
White epoxy
40
℃
+10
℃
Dry hands quickly:
Dry hands in 10s -12s
Heat switch:
Can be set to cold or hot air using the heat switch
.
Anion generator:
The anion generator inside
purifies
the surrounding air.
Fragrance holder:
An optional fragrance piece provides a fresh smell in the washroom as soon as
the
unit starts.
Appearance:
Robust
yet elegant.
Air speed
80m/s
Motor power
550W
1
Problem
Troubleshooting
Contact the local dealer
Reason
Solution
Contact local dealer
No working
No power
Check the power
Too short sensing distance
Adjust the distance
Sensor device is damaged
No warm air
Heat switch is off
Switch on
Heating wire got problem Contact the local dealer
Connect it well
The cable of sensor board
is loose with the power wire
Motor doesn t
work
Motor is damaged
1)This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible
for their safety. Children should be supervised to ensure that they do
not play with the appliance.
2)If the supply cord is damaged, it must be replaced by the manufacturer,
its service agent or similarly qualified persons in order to avoid a
hazard.