27
Room Temperature Inspection
In addition to the humidity level, the digital display can also indicate the current room
temperature. Please check as follows:
Press and hold the TIMER button for 5 seconds.
The screen displays the temperature in degree Celsius.
Automatic Defrost function
At low room temperatures, frost may buildup at the evaporator reducing the airflow across it
during dehumidifying.
The dehumidifier will automatically start defrosting.
The Defrost LED blinking.
The compressor stops and the fan keeps running.
Do not turn off the unit and it will automatically restart dehumidifying.
Overload Protection
In the event of a power loss, to protect the compressor there is a 3-minute delay until the
compressor restarting.
Memory Function
The system has auto memory. When all the mode setting has been finished, if there is sudden
power cut during operation, or the power jack slips out, the system may store the current status
before the power is cut and enter the operation mode before power cut automatically after power
is supplied.