5.  Unscrew the cover with a  

Phillips screwdriver.

8.  Slide the cover back onto the  

rear holding.

6.  Slide the cover out of the rear holding.

9.  Screw the cover back into place.

7.  Pull out the old UVC bulb carefully then 

carefully insert the replacement UVC bulb. 

Do not remove the outer plastic cover of 

the UVC replacement bulb.

1.  Compare the UVC bulb type specified in 

chapter “Maintenance” in the Use and Care 

Manual of your appliance with the bulb type 

indicated on the packaging of this replace-

ment bulb. 

Only use the replacement bulb 

if both types match.

Model DX 1000 Premium / DX 1000 Premium S – UVC bulb replacement instructions

10.   Reset the information on the controller.

Please take into account your DRY AGER 

model.

10.   Reset the information on the controller.

Please take into account your DRY AGER 

model.

 

DX 500 Premium S

·   Press   and   together and hold both keys 

for a minimum of 2 sec.

·  

Std is now shown in the display.  

Confirm this with the key  .

·  Use the key   to select the parameter 

UcH 

and confirm it with the key  . The displayed 

value is flashing.

·   Press  button  . The displayed value changes 

to „

0“.

·  After one minute, the display automatically 

switches back to the standard mode.

DX 500 Premium 

·   Press 

 and 

SET % RH together and hold 

both keys for a minimum of 2 sec.

·  Select with button   the parameter 

UcH 

and confirm it with the key 

SET % RH. The 

displayed value is flashing.

·   Press  button 

. The displayed value chan-

ges to „

0“.

·  After 1 minute the display automatically  

switches back into the standard mode.

2.  Remove all food from inside the appliance 

and store them in a cool place temporarily. 

3.  Switch the appliance off. Then discon-

nect the power cord or turn off the circuit 

breaker.

4.    Wear protection gloves.

Lava GmbH & Co. KG – Weitere Angaben erhalten Sie gerne auf Anfrage.  

Technische Änderungen und Druckfehler vorbehalten. Stand: 04/2022

Information Print Product:

Art.-Nr.: OIDX0101

 

DX 1000 Premium S

·   Press   and   together and hold both keys 

for a minimum of 2 sec.

·  

Std is now shown in the display.  

Confirm this with the key  .

·  Use the key   to select the parameter 

UcH 

and confirm it with the key  . The displayed 

value is flashing.

·   Press  button  . The displayed value changes 

to „

0“.

·  After one minute, the display automatically 

switches back to the standard mode.

DX 1000 Premium 

·   Press 

 and 

SET % RH together and hold 

both keys for a minimum of 2 sec.

·  Select with button   the parameter 

UcH 

and confirm it with the key 

SET % RH. The 

displayed value is flashing.

·   Press  button 

. The displayed value chan-

ges to „

0“.

·  After 1 minute the display automatically  

switches back into the standard mode.