5. Unscrew the cover with a
Phillips screwdriver.
8. Slide the cover back onto the
rear holding.
6. Slide the cover out of the rear holding.
9. Screw the cover back into place.
7. Pull out the old UVC bulb carefully then
carefully insert the replacement UVC bulb.
Do not remove the outer plastic cover of
the UVC replacement bulb.
1. Compare the UVC bulb type specified in
chapter “Maintenance” in the Use and Care
Manual of your appliance with the bulb type
indicated on the packaging of this replace-
ment bulb.
Only use the replacement bulb
if both types match.
Model DX 1000 Premium / DX 1000 Premium S – UVC bulb replacement instructions
10. Reset the information on the controller.
Please take into account your DRY AGER
model.
10. Reset the information on the controller.
Please take into account your DRY AGER
model.
DX 500 Premium S
· Press and together and hold both keys
for a minimum of 2 sec.
·
Std is now shown in the display.
Confirm this with the key .
· Use the key to select the parameter
UcH
and confirm it with the key . The displayed
value is flashing.
· Press button . The displayed value changes
to „
0“.
· After one minute, the display automatically
switches back to the standard mode.
DX 500 Premium
· Press
and
SET % RH together and hold
both keys for a minimum of 2 sec.
· Select with button the parameter
UcH
and confirm it with the key
SET % RH. The
displayed value is flashing.
· Press button
. The displayed value chan-
ges to „
0“.
· After 1 minute the display automatically
switches back into the standard mode.
2. Remove all food from inside the appliance
and store them in a cool place temporarily.
3. Switch the appliance off. Then discon-
nect the power cord or turn off the circuit
breaker.
4. Wear protection gloves.
Lava GmbH & Co. KG – Weitere Angaben erhalten Sie gerne auf Anfrage.
Technische Änderungen und Druckfehler vorbehalten. Stand: 04/2022
Information Print Product:
Art.-Nr.: OIDX0101
DX 1000 Premium S
· Press and together and hold both keys
for a minimum of 2 sec.
·
Std is now shown in the display.
Confirm this with the key .
· Use the key to select the parameter
UcH
and confirm it with the key . The displayed
value is flashing.
· Press button . The displayed value changes
to „
0“.
· After one minute, the display automatically
switches back to the standard mode.
DX 1000 Premium
· Press
and
SET % RH together and hold
both keys for a minimum of 2 sec.
· Select with button the parameter
UcH
and confirm it with the key
SET % RH. The
displayed value is flashing.
· Press button
. The displayed value chan-
ges to „
0“.
· After 1 minute the display automatically
switches back into the standard mode.