Drummond submersible Manual Download Page 3

Page 3

For technical questions, please call 1-888-866-5797.

Item 63477 
        

Specifications

Electrical Rating

120 VAC / 60 Hz / 8.5 A

Power Cord Length

25'

Maximum Flow @ 0' Head Lift

4400 GPH

Maximum Head Lift @ 0 GPH Flow

40'

Discharge Port

1-1/4" NPT

Discharge Port Adapter

1-1/4" NPT to 3/4" garden hose thread

Installation

The submersible motor Pump must be installed in a stationary position with either:

a.  A fixed pipeline or
b.  A flexible hose pipe.

Please note!

1.  Do not install the Pump by suspending it 

unsupported from its delivery pipe or power cord.  
The Pump must be suspended from the handle 
or be placed on the bottom of the basin.  
To ensure that the Pump works properly, keep the 
bottom free from sludge and dirt of all kinds.

2.  If the water level sinks too low, any sludge in the 

basin will dry out and stop the Pump from starting.  
To help ensure the Pump will start as required, 
check the Pump regularly with start-up tests. 

Power Supply

1.  The Pump is equipped with a shock-proof plug 

according to regulations.  The Pump is designed 

to be connected to a 120 VAC, 60 Hz, 

Ground 

Fault Circuit Interrupter (GFCI) protected socket.

2.  Make sure that the socket is sufficiently 

secured and is in excellent condition.

3.  When the plug is inserted into the socket, 

the Pump will start operating.

4. 

WARNING: To prevent death from electric 
shock, Pump must be connected only to 
a GFCI protected outlet.

WARNING!

  If the power cord or plug is damaged, 

do not use the Pump.  The power cord or plug 
may only be repaired by a certified electrician.

Areas of use

1.  This Pump is designed to pump water only.

2.  This Pump is designed to be used for:

•  Removing ground water from 

basements and outdoor job sites

•  Very high flow

3.  This Pump should NOT be used for:

•  Continuous run, fountain/pond water features  
•  Basement sump applications
•  Septic or sewage systems
•  Potable water systems 

4.  This Pump can also be used to transfer water 

(e.g. household, farming, plumbing).

Summary of Contents for submersible

Page 1: ...ence 17d When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2017 by Harbor Freight Tools All...

Page 2: ...d at all costs 6 The Pump must be protected from frost 7 The Pump must be protected from running dry 8 Access by children should also be prevented with appropriate measures 9 To prevent death from ele...

Page 3: ...rt as required check the Pump regularly with start up tests Power Supply 1 The Pump is equipped with a shock proof plug according to regulations The Pump is designed to be connected to a 120VAC 60Hz G...

Page 4: ...art the Pump Operation After reading these instructions consider the following points before starting the Pump 1 Verify that the Pump rests on the floor of the basin if it is not suspended by the hand...

Page 5: ...ne voltage 4 Check valve sold separately stuck or installed backwards 1 Clean out dirt and debris from impeller 2 There must be at least 2 1 4 deep water for the Pump to operate properly 3 Consult an...

Page 6: ...1 Power Cable 1 3 Self Tapping Screw 5 4 Main Body Subassembly 1 5 Screw 4 6 O Ring 2 7 Base Cover 1 8 Cable Sheath 1 9 Cable Guide 1 10 Cable Fastener 2 11 Capacitor 35Uf 1 12 Cable Connector 1 13 S...

Page 7: ...Page 7 For technical questions please call 1 888 866 5797 Item 63477 Assembly Diagram...

Page 8: ...o the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take a...