For technical questions, please call 1-888-866-5797.

Item 58012 

       

Installation Instructions

1.  Construct a basin that is at least 

14″ 

deep 

and at least 

10″ 

in diameter.

at least

at least 10

 10

″″

  

diameter

diameter

at leastat least

 14 14

″″

 deep deep

Sump 

Basin

Inlet Pipe

Figure A:  Sump Basin

2.  Position Pump on solid surface so that both 

hoses are free from kinks and the Float Switch 

is away from the inlet pipe and at least 1″ away 

from all obstructions throughout its movement.

3.  Fit a sump cover with a hole for the discharge pipe.  

Set the sump cover aside for now. Place unused 
end of discharge pipe as needed to direct the water 
discharge at least 3 feet away from the source.  Slope 
the discharge pipe downward, away from the source. 

Note:

  The sump cover can also be 

fitted with a vent pipe, if desired.

Discharge 

Pipe

Pump 

Cord

Sump Cover

Pump

Figure B:  Pump Position

4.  Attach a discharge pipe to the Pump Outlet.

Note:

 Wrap all threaded connections 

with PTFE thread seal tape.

5.  Check Valve is sold separately. Install 

according to manufacturer instructions.

6.  To prevent excessive cycling from backflow 

of water, install a check valve onto the 
discharge pipe.  This prevents water from 
flowing back after the pump shuts off.

Discharge 

Pipe

Pump 

Cord

Sump Cover

Pump

Pump 

Outlet

Check 

Valve

GFCI-Protected 

Receptacle

Figure C:  Outlet Pipe and Plug

7.  Connect additional Discharge Pipe as needed 

to direct the water discharge at least 3 feet 
away from the foundation.  Slope the discharge 
pipe downward, away from the foundation.  
The discharge should be kept as short as 
possible with a minimum number of turns.

IMPORTANT:  Do not exceed the 
Maximum Head Lift @ 0 Flow of the Pump.

Summary of Contents for 58012

Page 1: ...dry place for future reference 20k When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2020 by...

Page 2: ...higher ground 5 Circulation of caustic fluids as well as the circulation of abrasive materials must be avoided at all costs 6 The pump must be protected from frost 7 The pump must be protected from ru...

Page 3: ...will start as required check the pump regularly with start up tests Power Supply 1 The pump is equipped with a shock proof plug according to regulations The pump is designed to be connected to 120 VA...

Page 4: ...e Note The sump cover can also be fitted with a vent pipe if desired Discharge Pipe Pump Cord Sump Cover Pump Figure B Pump Position 4 Attach a discharge pipe to the Pump Outlet Note Wrap all threaded...

Page 5: ...ts on the floor of the basin 2 Verify that the discharge pipe is properly connected 3 Verify that the electrical connection is 120 VAC 60 Hz 4 Verify that the electrical socket is GFCI protected and i...

Page 6: ...out with clean water after every use Quarterly Maintenance The below maintenance must be performed at least once every 3 months under optimal conditions For frequent use or dirty areas more frequent m...

Page 7: ...1 6 Gasket 1 7 Volute 1 8 Screw 7 9 Adaptor 1 10 Float Switch 1 Record Product s Serial Number Here Note If product has no serial number record month and year of purchase instead Note Some parts are l...

Page 8: ...amages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS T...

Reviews: