Determine the remaining length for the wall or roof terminal and cut it to size, make sure the correct insertion
length is maintained.
Ø
Place the wall terminal with the (groove/folded) seam at the top.
!Caution
When using the wall terminal, place the terminal with a downward slope of 1 cm / metre towards the outside, in
order to prevent rain water from raining in.
5.8.4 Connection to an existing chimney
It is possible to connect the appliance to an existing chimney.
A flexible SS pipe is placed in the chimney with a fitting diameter at the flue gas discharge pipe, for the discharge
of flue gas. The surrounding space is used to supply combustion air.
The following requirements apply when connecting to an existing chimney:
•
only allowed when used in combination with the special DRU chimney kit. The installation regulation is also
supplied;
•
the internal dimensions should be at least 150 x 150 mm;
•
the vertical length has a maximum of 12 metres;
•
the total horizontal pipe length may have a maximum length that you can find in Appendix 2, Table 4;
•
the existing chimney has to be clean;
•
the existing chimney has to be tight.
For adjusting the appliance, the same conditions/instructions apply as for the concentric system described above.
11
Summary of Contents for 0063CO3296
Page 29: ...E n g l i s h INSTALLATION MANUAL 29 L M 38C 2192 1 P 38C 2193 0 11 10...
Page 30: ...E n g l i s h INSTALLATION MANUAL 30 R 38C 2194 0 12...
Page 33: ...E n g l i s h INSTALLATION MANUAL 33 38P 0587 0 B A 38P 0586 0 C 21 20...
Page 34: ...E n g l i s h INSTALLATION MANUAL 34 38P 0585 0 D 38P 0584 0 E E 23 22...
Page 35: ...E n g l i s h INSTALLATION MANUAL 35 38P 0583 0 F G 38P 0582 0 H 38P 0589 0 24 25 26...
Page 37: ...E n g l i s h INSTALLATION MANUAL 37 38C 1940 44...
Page 38: ...E n g l i s h INSTALLATION MANUAL 38...