1. INTRODUCTION 

 
This operation and maintenance manual refers to

 "

PoliPUMP 

eco

" electric pump

 and contains important information for 

the health and safety protection of the personnel who use this equipment. 
The  most  recent  version  can  be  obtained  by  requesting  it  from  the  Sales  Technical  Office  or  online  at 

http://www.dropsa.com. 

 

This manual must be read carefully and kept so that it is always available to the operators who want to consult it.

 

 

2. GENERAL DESCRIPTION 

 

2.1 DIRECT-POINT LUBRICATION 

 

 

The 

PoliPUMP 

eco

  electric  pump  directly  lubricates  friction  points  without  needing  to  use  other  flow-rate  dosing 

devices. This allows you to have a product for inexpensive lubrication that is versatile and easy to use. 

PoliPUMP

 

eco

  was  developed  to  supply  lubrication  systems  at  a  single  point  in  vehicles,  in  installations  and  in  various 

types of machinery, for use with grease. Any use other than the use intended shall be deemed to be in non-compliance 
with requirements.  
 

2.2 SPECIFICATIONS

 

 

The 

PoliPUMP  eco

  electric  pump  is  a  piston  pump  driven  by  an  eccentric  system,  designed  to  be  operated  with  a 

maximum of 35 pumping elements, allowing several independent lines to be supplied. 
It is supplied as a standard without pumping elements, which must be ordered separately by choosing the desired flow 
between six models that can be identified by pairing different colours. La standard version has a reservoir with a capacity 
of 2 litres. 
A contoured stirring paddle and reservoir wiper set eliminate the presence of air bubbles in the lubricant contained within 
the pump, thereby ensuring proper operation, even at low temperatures. 
The pump is driven by a 12 or 24V DC gear motor. 
 

3. PRODUCT IDENTIFICATION 

 

A label is located on the side of the pump that indicates the product part number, the 
power supply voltages and the basic features. 

 

 

 
 
 
 
 

Summary of Contents for PoliPUMP eco

Page 1: ...ng and Maintenance Manual Original Instructions Manual drawn up in accordance with EC Directive 06 42 C2291IE WK 24 19 Dropsa products can be purchased from Dropsa bracnhes and authorized distributors...

Page 2: ...UNPACKING 6 6 2 INSTALLATION OF PUMPING ELEMENTS CAPS 6 7 OPERATING INSTRUCTIONS 8 7 1 MEASURES TO BE TAKEN PRIOR TO START UP 8 7 2 USE 9 7 3 FILLING THE RESERVOIR 9 8 PROBLEMS AND SOLUTIONS 10 9 MAIN...

Page 3: ...ions and in various types of machinery for use with grease Any use other than the use intended shall be deemed to be in non compliance with requirements 2 2 SPECIFICATIONS The PoliPUMP eco electric pu...

Page 4: ...pumping element 80bar 1 160psi Reservoir capacity 2 litres 0 53 gallons Grease consistency NLGI00 NLGI2 Protection degree IP 69 Temperature of use 10 C 60 C 14 F 140 F Storage temperature 20 C 80 C 4...

Page 5: ...GREY 5 notches 0 10cc cycle BLACK 6 notches 0 13cc cycle Push in outlet 4 Notches Pump replacement cap included within the scope of supply Stirring paddle with wiper reservoir Input power cable gland...

Page 6: ...ition by distributing them evenly over the holes on the pumping element holder cylinder No MOUNTING POSITIONS No MOUNTING POSITIONS No MOUNTING POSITIONS 1 1 13 13 25 25 2 1 7 14 13 19 26 25 31 3 1 5...

Page 7: ...e pipes and wires have been properly fastened and protected from any possible impact Verify that the grease used is fit for operating temperatures especially at temperatures below 0 C If in doubt cont...

Page 8: ...temperature and that the pipelines are free of any air bubbles Check the correct connection of electrical devices To determine the maximum operating pressure it is necessary to know the pressure drop...

Page 9: ...the maximum level line If this happens you will note a spill of lubricant from the underside of the lid which acts as an air vent 7 4 HOW TO USE If there are no regulations foreseen the pump is electr...

Page 10: ...e time The pump begins the greasing phase but ends it immediately Defective motor or high output absorption Allow to cool for a few minutes and try again If the problem persists replace the gear motor...

Page 11: ...s the periodic inspections the frequency and the intervention that the maintenance will have to carry out in order to ensure the efficiency of the system over time CHECK FREQUENCY INTERVENTION Attachm...

Page 12: ...888274 ECO 0888275 ECO 0 04cc cy cle 0888453 0 13cc cycle 0888456 OPTIONAL SPARE PARTS PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION 5717300 Nylon tube 4x3 low pressure 0888257 Pump replacement cap...

Page 13: ...ND TRANSPORT Before shipment the pumps are carefully packed inside a cardboard box During transport and storage of the equipment pay attention to the direction indicated on the box Upon receipt check...

Page 14: ...ISO 12100 Electrical safety requirements EN 60204 1 The hazards that have not been entirely eliminated but that have been deemed acceptable are listed below During the maintenance phase low pressure s...