5
6. OVER-PRESSURE INDICATOR
Pressure indicators are used to control pressure in main or secondary tubing. They can be applied directly on the
alternate outlet/indicator port that is standard on all nPr divider elements. There are three types of indicators that
give a different visual indication linked to the pressure set on the device. Below are shown the characteristics of
each pressure indicator and the part number.
The burst indicator must be replaced on each overpressure event. The lubricant will be discharged to atmosphere
.
7. TUBING, FITTINGS AND VALVES
Tubing, fittings and valves used in conjunction with the divider must be rated at the max pressure which the system
can operate at. Below a selection of components that you can be useful to assembly the divider blocks.
PART
NUMBER
DESCRIPTION
PART
NUMBER
DESCRIPTION
0092335 1/8” valved fitting for OUTLETS
5119812 Ø6x1 Drawn steel tube (400bar)
0092555 1/8” valved fitting for INLET
5119832 Ø4x1 Drawn steel tube (500bar)
0092080 Ø6 comrpession fitting (150bar)
5118001 ASTM Ø6x0,71 Copper steel tube (310bar)
0092069 Ø4 bicone fitting (150bar)
5118000 ASTM Ø4x0,71 Copper steel tube (500bar)
0091942 Ø4 bicone fitting (250bar)
5501201 Ø4x0,5 Annealed copper tube (133bar)
3084577 Push-in Ø4 (65bar)
5501203 Ø6x1 Annealed copper tube (200bar)
3084578 Push-in Ø6 (65bar)
5717202 PA Ø4xØ2,5 Tube (60bar)
3084695 Swivel Push-in 90° Ø6 (150bar)
5717203 PA Ø6xØ4 Tube (50bar)
3084696 Swivel Push-in 90° Ø4 (150bar)
Indicator with pin and memory
(M)
Indicator with pin
(P)
Burst membrane indicator
(B)
Pressure [bar]
PART NUMBER
Pressure [bar]
PART NUMBER
Pressure [bar]
PART NUMBER
30
3290000
20
3290019
30
3290012
50
3290001
30
3290006
50
3290013
75
3290022
50
3290007
100
3290014
100
3290002
100
3290008
150
3290015
150
3290003
150
3290009
200
3290016
200
3290004
200
3290010
250
3290017
250
3290005
250
3290011
300
3290021
(The pin remains locked in position
until reset manually for ease of
troubleshooting).
The Pin retracts once the pressure
drops back under the indicator
limit.
In this type the membrane breaks
in case the pressure overcome the
set pressure.