background image

4. 

COMPONENTS

 

 

Micro-electric pump

: The pump is cam actuated and the piston is spring controlled. The cycle time is fixed and is 

determined by the type of reducer fitted to the electric motor. The flow rate varies between 0,2

÷

1cm³ e da 1

÷

5cm³. The 

operating pressure is 4 bar. It is suitable for oil with a viscosity of 32

÷

250 cSt at a fluid working temperature b5 

°C and +40 °C. 

Should it be required to use a different specification product, prior authorisation should be obtained from Dropsa S.p.A. 

Electric Motor:

 Single phase motor 50-60 Hz, 24, 110 or 220 V. the absorbed power is 2.5 W – 3.5 VA at 50 Hz and 2 W – 

2.5 VA at 60 Hz. Admissible voltage variation is ±10%. 

 

Protection grade IP 54 

insulation class - F 

continuous service - YES 

 

Reservoir: 

made of transparent plastic material in 1 L version and white plastic in 1.7 L version.

 

Minimum level indicator 

Magnetic type  

Reversible float with contact normally open at rest. To convert to normally open contact turn the float upside down. The 

maximum power is 50 W ÷ 50 VA; the maximum voltage is 220 V ac – 150 V dc. 

Suction filter: 

Filtration grade 260 micron 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 
 
 

 
 
 
 
 
 

Summary of Contents for 3417000 Series

Page 1: ...RACTERISTICS 6 HANDLING AND TRANSPORTATION 7 PRECAUTIONS 8 OPERATING HAZARDS 9 UNPACKING AND INSTALLING 10 INSTRUCTIONS FOR USE 11 TROUBLESHOOTING 12 MAINTENANCE PROCEDURES 13 DISPOSAL 14 DIMENSIONS 1...

Page 2: ...roperty and will release them from all obligations arising from the guarantee 2 IDENTIFICATION OF THE MACHINE On the front part of the pump tank there is a plate which indicates the product code the s...

Page 3: ...authorisation should be obtained from Dropsa S p A Electric Motor Single phase motor 50 60 Hz 24 110 or 220 V the absorbed power is 2 5 W 3 5 VA at 50 Hz and 2 W 2 5 VA at 60 Hz Admissible voltage va...

Page 4: ...n a dry location 7 PRECAUTIONS It is necessary to carefully read the warnings and risks associated with using a lubricant pump The operator must understand how it works and must clearly understand the...

Page 5: ...the perimeter of the pump Mount the pump at eye level to avoid any risk of postural problems There are two fixing holes on the plate with different distances depending on the 1 Lt and 1 7 Lt version A...

Page 6: ...en centres Use gloves and safety glasses as required in the lubrication oil safety chart DO NOT use aggressive lubricants with NBR gaskets and seals if in doubt consult the Engineering Department of D...

Page 7: ...re the pump is positing so that it can be verified easily Ensure you have necessary personal protective equipment to avoid any contact with the grease The pump undergoes severe factory testing therefo...

Page 8: ...into the environment Refer to local regulations with regard to their correct disposal When scrapping the machine the identification plate and any other documents must be destroyed 14 DIMENSIONS 1 Lt R...

Page 9: ...10 15 DIMENSIONS 1 7 Lt RESRVOIR MODEL PART NUMBER DIMENSIONS WHEIGHT Kg 1 7 lt made in white plastic 3044071 194x115x234 0 315...