36
Clearances with ceiling (L) lowered to 68" (173 cm)
APPLIANCE CLEARANCES
(INSTALLATION WITH SINGLE
WALL PIPE CONNECTOR)
CANADA
USA
A
15½" (394 mm)
15" (381 mm)
B
18" (457 mm)
18" (457 mm)
C
12" (305 mm)
12" (305 mm)
K
48" (1220 mm)
48" (1220 mm)
L
68" (173 cm)
68" (173 cm)
APPLIANCE CLEARANCES
(INSTALLATION WITH DOUBLE
WALL PIPE CONNECTOR)
CANADA
USA
A
12" (305 mm)
12" (305 mm)
B
18" (457 mm)
18" (457 mm)
C
10" (254 mm)
10" (254 mm)
K
48" (1220 mm)
48" (1220 mm)
L
68" (173 cm)
68" (173 cm)
Note: These clearances are also valid for an alcove installation.
If the above clearances are met, then the distances measured from the flue outlet
will be:
DISTANCES* FROM PIPE
CONNECTOR TO THE
COMBUSTIBLE MATERIALS
CANADA
USA
D
18" (457 mm)
17½" (455 mm)
E
26¼" (667 mm)
26¼" (667 mm)
F
20" (508 mm)
20" (508 mm)
DISTANCES* FROM PIPE
CONNECTOR TO THE
COMBUSTIBLE MATERIALS
CANADA
USA
D
14½" (368 mm)
14½" (368 mm)
E
26¼" (667 mm)
26¼" (667 mm)
F
18" (457 mm)
18" (457 mm)
*The pipe distances listed in this table refer to the distances obtained when the
stove is installed in accordance with the appliance clearances above mentioned.
However, you can install the stove at reduced clearances; follow the instructions in
Section 8.4: Reducing Wall and Ceiling Clearances Safely. Where they are followed,
the new distance of the pipe to combustible materials must be respected in the
appropriate certification of the pipe.
Summary of Contents for Spark DB03400
Page 30: ...Spark Installation and Operation Manual 30 Assembly steps 1 2...
Page 31: ...Spark Installation and Operation Manual 31 3 4...
Page 32: ...Spark Installation and Operation Manual 32 5 6...
Page 33: ...Spark Installation and Operation Manual 33 7 8...
Page 40: ...Spark Installation and Operation Manual 40 Clearances for shield construction...
Page 53: ...Spark Installation and Operation Manual 53 Appendix 4 Exploded Diagram and Parts List...