Drolet SIBERIAN 1200 Owner'S Manual Download Page 28

 

1700, rue Léon-Harmel, Québec (Québec) G1N 4R9 

tel. : (418) 527-3060    fax : (418) 527-4311 

e-mail : [email protected]    web site : www.drolet.ca 

LIMITED LIFETIME WARRANTY 

The warranty of the manufacturer extends only to the original consumer purchaser and is not transferable. This 
warranty covers brand new products only, which have not been altered, modified nor repaired since shipment from 
factory. Proof of purchase (dated bill of sale), model name and serial number must be supplied when making any 
warranty claim to your Drolet  dealer  

This warranty applies to normal residential use only.  Damages caused by misuse, abuse, improper 
installation, lack of maintenance, over firing, negligence or accident during transportation are not covered 
by this warranty. 

This warranty does not cover any scratch, corrosion or discoloration caused by over firing, abrasives or chemical 
cleaners. Any defect or damage caused by the use of unauthorized parts or others than original parts void this 
warranty. 
An authorized qualified technician must perform the installation in accordance with the Instructions supplied with this 
product and all local and national building codes. Any service call related to an improper installation is not covered by 
this warranty. 
Returned products are to be shipped prepaid to the manufacturer for investigation. If a product is found to be 
defective, the manufacturer will repair or replace such defect and reasonable transportation fees will be refund. 
Repair work covered by the warranty, executed at the purchaser domicile by an authorized qualified technician 
requires the prior approval of the manufacturer. Labour cost and repair work to the account of the manufacturer are 
based on predetermined rate schedule and must not exceed the wholesale price of the replacement part. 
The manufacturer at its discretion may decide to repair or replace any part or unit after inspection and investigation 
of the defect. The manufacturer may, at its discretion, fully discharge all obligations with respect to this warranty by 
refunding the wholesale price of any warranted but defective parts  
The manufacturer shall in no event be responsible for any special, indirect, consequential damages of any nature, 
which are in excess of the original purchase price of the product. 
 

WARRANTY APPLICATION 

DESCRIPTION 

PARTS LABOUR 

Combustion chamber (weldings only) 

Lifetime 

5 years 

Stainless baffle 

5 years 

1 year 

Carbon steel baffle 

2 years 

1 year 

Handle assembly 

5 years 

n/a 

Ash drawer 

Lifetime 

1 year 

Cast iron parts 

5 years 

1 year 

Ceramic glass (thermal breakage only) 

1 year 

n/a 

Paint, refractory bricks, gasket, blower, thermal switch (thermodisc) 
and rheostat 

1 year 

n/a 

Gold plating (tarnishing) 

1 year

 

n/a 

Shall your unit or a components be defective, contact immediately your 

Drolet 

 dealer. Prior to your call make sure you have the 

following information necessary to your warranty claim treatment: 

• 

You name, address and telephone number;  

• 

Bill of sale, dealer’s name; 

• 

Serial number and model name as indicated on the 

nameplate fixed to the back of your unit; 

• 

Nature of the defect and any relevant information. 

Before shipping your unit or defective component to our plant, you must obtain from your Drolet dealer an Authorization 
Number. Any merchandise shipped to our plant without authorization will be refused automatically and returned to 
sender.

 

 

 

27 

Summary of Contents for SIBERIAN 1200

Page 1: ...PHASE II CERTIFIED WOODSTOVES V rified and tested following ULC S627 et UL 1482 Standards by Intertek Testing Services READ AND KEEP THIS MANUAL FOR REFERENCE Manufactured by STOVE BUILDER INTERNATION...

Page 2: ...OR ADJUSTMENT 9 THE BENEFITS OF INSTALLING A BLOWER 10 INSTALLATION 11 POSITIONING THE STOVE 11 FLOOR PROTECTOR 12 CLEARANCES 13 REDUCED CLEARANCES 14 CHIMNEY 15 CHIMNEY CONNECTOR STOVE PIPE 16 TYPICA...

Page 3: ...s not properly installed a house fire may result To reduce the risk of fire follow the installation instructions Failure to follow instructions may result in property damage bodily injury or even deat...

Page 4: ...2 100 F 650 C Minimum Chimney Height 12 3 66 m 12 3 66 m 12 3 66 m Maximum Log Length 16 406 mm 18 457 mm 19 483 mm Dimensions Overall W x D x H 23 7 8 x 23 x 29 607 x 584 x 756mm W x D x H 26 3 8 x...

Page 5: ...tove but only four will align with the pedestal 4 Slide the front part of the pedestal base around the pedestal and fix the rear part with the two supplied screws 5 Slide the ash pan in position for D...

Page 6: ...be installed according to figure 4 In both stoves the baffle brick must be pushed as close to the front as possible onto its metallic support The upper bricks 2 must lay on the vertical bricks 4 grove...

Page 7: ...all the back bricks 6 x 4 1 2 x 9 4 Install the bottom bricks 4 x 4 1 2 x 9 2 x 6 x 7 5 Install the T shape support and the bricks 4 x 4 1 2 x 9 2 x 3 x 9 6 Install the baffle bricks 4 x 4 1 2 x 9 2 x...

Page 8: ...s necessary to remove the two front secondary air tubes First place only one baffle brick and one white ceramic insulation Use the same method to put the other baffle brick and insulation Put back in...

Page 9: ...of the tube are on the left side Insert one tube in the right side air channel and slide it to the right as much as possible Bring the left end of the tube aligned with the ring welded to the left ai...

Page 10: ...sted periodically to provide an air tight fit To adjust Remove the lock pin spring pin by pulling and turning it using pliers wise grip Turn the handle counter clock wise one turn to increase pressure...

Page 11: ...toward the front the blower enables you to extend the radiation power of your stove You can purchase this option through your DROLET dealer Make sure to specify this part number AC02050 You can also...

Page 12: ...TEM A SOURCE OF FRESH AIR INTO THE ROOM OR SPACE HEATED SHALL BE PROVIDED WHEN REQUIRED POSITIONING THE STOVE It is very important to position the wood stove as close as possible to the chimney and in...

Page 13: ...n inches beyond the front and eight inches beyond each side of the fuel loading and ash removal opening If there is a horizontal section of chimney connector the floor protector should go under it and...

Page 14: ...wall pipe USA A B C D E F SIBERIAN 1200 17 12 5 8 8 10 7 22 4 17 9 20 20 22 4 19 4 SIBERIAN 1600 15 12 14 12 12 8 20 8 17 8 27 2 25 2 25 5 21 5 SIBERIAN 2000 15 10 10 8 7 5 21 3 16 3 24 9 22 9 22 1 20...

Page 15: ...shield the clearances mentioned on the stove certification plate may be reduced as stated in the following table Reducing Clearances With Shielding TYPE OF PROTECTION Sides and Rear Back Top Sheet me...

Page 16: ...draught effect your stove s performance is directly dependent on an adequate draught from your chimney The following recommendations may be useful for the installation of your chimney 1 Do not connect...

Page 17: ...installed horizontally must slope at least 1 4 inch per foot with the upper end of the section toward the chimney To insure a good draught the total length of the coupling pipe should never exceed 8 t...

Page 18: ...TYPICAL INSTALLATIONS FACTORY BUILT CHIMNEY ROOF FLASHING 18 CLEARANCE WALL SUPPORT WALL RADIATION SHIELD RAIN CAP Wall installation CEILING SUPPORT RADIATION SHIELD Vertical installation 17...

Page 19: ...MASONRY CHIMNEY Clay liner Thimble Clean out door 18...

Page 20: ...FACTORY BUILT THIMBLE 19...

Page 21: ...BRICK THIMBLE 20...

Page 22: ...d Hemlock 17 Spruce 17 Pine 17 Bass 16 Low energy yield Fir 13 Data provided by Energy Mines and Resources Canada IT IS EXTREMELY IMPORTANT THAT YOU USE DRY WOOD ONLY IN YOUR WOOD STOVE The wood must...

Page 23: ...achieve a medium burn rate Make sure that there s enough air circulation while curing the stove The odours could be smelled during the 3 or 4 first fires Never start your stove outside You will not b...

Page 24: ...will be achieved according to control setting Low Medium Medium high High SIBERIAN 1200 full close 7 16 7 8 full open SIBERIAN 1600 full close 1 4 5 8 full open SIBERIAN 2000 full close 1 2 1 full ope...

Page 25: ...ION AND NEED FOR REMOVAL When wood is burned slowly it produces tar and other organic vapours which combine with expelled moisture to form creosote The creosote vapours condense in the relatively cool...

Page 26: ...away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the close container until all cinder...

Page 27: ...alized product available in the stores where wood stoves are sold The glass should be washed only when cold GASKETING It is recommended that you change the door gasket which makes your stove door air...

Page 28: ...ires the prior approval of the manufacturer Labour cost and repair work to the account of the manufacturer are based on predetermined rate schedule and must not exceed the wholesale price of the repla...