TABLE OF CONTENT
TECHNICAL DATA ......................................................................................................................................... 1
INSTALLATION INSTRUCTIONS .................................................................................................................. 2
LOCATING THE STOVE ......................................................................................................................... 2
CHIMNEY INFORMATIONS.................................................................................................................... 3
CONNECTING THE STOVE TO THE CHIMNEY ................................................................................... 4
LEVELING THE UNIT.............................................................................................................................. 5
FIXATION OF STOVE TO FLOOR.......................................................................................................... 6
CONNECTING STOVE TO OIL TANK .................................................................................................... 6
AJUSTEMENT THE DRAUGHT.............................................................................................................. 7
OPERATION INSTRUCTIONS ....................................................................................................................... 8
COMBUSTIBLE ....................................................................................................................................... 8
LIGHTING PROCEDURES ..................................................................................................................... 8
CHANGING INTENSITY.......................................................................................................................... 9
TURNING THE STOVE OFF ................................................................................................................... 9
CLEANING PROCEDURES .................................................................................................................... 9
TROUBLESHOOTING GUIDE .............................................................................................................. 10
TECHNICAL DATA
EVEREST OIL BURNING STOVE
COMBUSTIBLE
:
OIL N
O
1
OIL N
O
2
HEAT INPUT :
Kw BTU/h
Kw BTU/h
Minimum:
5,9 20
450
4,8 16
600
Maximum:
10,9
37 250
9,6
33 150
FLOWRATE :
cc/min
litres/h
cc/min
litres/h
Minimum:
9,9 0,60
7,5 0,45
maximun:
17,3 1,04
16,1 0,97
MINIMUM DRAUGHT REQUIRED :
0,06 INWC
0,06 INWC
EFFICIENCY :
%
%
with fan :
78,5
79
without fan :
77
77
CLEARANCES TO COMBUSTIBLES
Mm
in
Back 255
10
Side 255
10
Corner 255
10
Top 915
36
A MINIMUM CLEARANCE OF 9’’ (230 mm)
FROM SINGLE WALL FLUE PIPE TO
COMBUSTIBLES MUST BE ALLOWED.
DIMENSIONS
mm
in
Height :
990
39
Width :
520
20
Depth :
680
26 ¾
Ø outlet flue pipe :
130
5
Ø burner :
255
10
Glass ( 3 ) :
92 x 250
3
5/8
x 9
7/8
Weight :
93 kg
204 lbs
Page 1 of 15