ELATION Fireplace Insert
12
•
If you wish to make a direct electrical connection to the blower without using the six-foot
cord supplied, route a 120 volt, 60 Hz electrical power supply line to the same location.
Remove the power cord and connect the 120V line as per the following procedure :
•
Unscrew the speed control unit and pull a few inches away from the junction box
•
Unscrew the two marr connectors attached to the cord (P) and the cord ground
•
Remove the cord and route the supply line through the same holes
•
Make the electrical connection with the same wires the cord was attached to
•
Screw the ground wire to the junction box (G)
•
Screw the speed control unit back in place
P
P
G
CONNECT THE POWER LINE TO THE SAME
WIRES THE CORD WAS CONNECTED TO (P)
SPEED CONTROL
JUNCTION BOX
If you prefer to use the six-foot cord supplied, just connect it to a 120V outlet.
•
Move the ELATION to the desired position and shim the unit to a level position.
•
Connect gas line to the insert at the right side using listed connectors
•
Check the gas line piping for leaks. Use a soap and water solution.
WARNING:
DO NOT USE OPEN FLAME TO CHECK LEAKS.