Page 29
Installation and Operation Manual - HT-3000
ENGLISH
8.1.2 With Lowered Ceiling
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES
15
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
11" (279 mm)
11" (279 mm)
D
15 ¾" (400 mm)
15 ¾" (400 mm)
B
16" (406 mm)
16" (406 mm)
E
26
⅞
" (683 mm)
26
⅞
" (683 mm)
C
10" (254 mm)
10" (254 mm)
F
20 ¾" (527 mm)
20 ¾" (527 mm)
L
72" (1,830 mm)
72" (1,830 mm)
8.1.3 With Heat Shield AC02710 or AC02762 and Lowered Ceiling
16
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES
15
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
2 ½" (64 mm)
2 ½" (64 mm)
D
7 ¼" (184 mm)
7 ¼" (184 mm)
B
2 ½" (64 mm)
2 ½" (64 mm)
E
13
⅜
" (340 mm)
13
⅜
" (340 mm)
C
2 ½" (64 mm)
2 ½" (64 mm)
F
13 ¼" (337 mm)
13 ¼" (337 mm)
L
74" (1,880 mm)
74" (1,880 mm)
8.1.4 Inside an Alcove
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES
15
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
11" (279 mm)
11" (279 mm)
D
15 ¾" (400 mm)
15 ¾" (400 mm)
B
16" (406 mm)
16" (406 mm)
E
26
⅞
" (683 mm)
26
⅞
" (683 mm)
K
48" (1220 mm)
36" (910 mm)
L
74" (1,880 mm)
74" (1,880 mm)
15
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
above mentioned.
16
Note that to reduce the clearances of an appliance using a single wall pipe connector, the use of a heat shield certified with the single wall pipe
connector to be used as close as 6» from combustible materials must be used. Only in this case, the same clearances as a certified double wall
pipe connector can be used.