background image

Page 7

Installation and Operation Requirements - Deco Alto

ENGLISH

2.3  Dimensions

2.3.1  Stove Dimensions

22  3/4"

578mm

16  3/4"

425mm

10  1/4"

260mm

17  1/8"

435mm

12  1/8"

307mm

37

  5

/8

"

95

5m

m

39

  3

/4

"

10

09

m

m

21  3/8"

543mm

26  1/2"

674mm

7  3/8"

188mm

12  7/8"

325mm

25  5/8"

651mm

O

6"

153mm

Figure 1: Top View

22  3/4"

578mm

16  3/4"

425mm

10  1/4"

260mm

17  1/8"

435mm

12  1/8"

307mm

37

  5

/8

"

95

5m

m

39

  3

/4

"

10

09

m

m

21  3/8"

543mm

26  1/2"

674mm

7  3/8"

188mm

12  7/8"

325mm

25  5/8"

651mm

O

6"

153mm

22  3/4"

578mm

16  3/4"

425mm

10  1/4"

260mm

17  1/8"

435mm

12  1/8"

307mm

37

  5

/8

"

95

5m

m

39

  3

/4

"

10

09

m

m

21  3/8"

543mm

26  1/2"

674mm

7  3/8"

188mm

12  7/8"

325mm

25  5/8"

651mm

O

6"

153mm

Figure 2: Front View

Figure 3: Side View

Summary of Contents for DB03220

Page 1: ...dards by an accredited laboratory US Environmental Protection Agency phase II certified wood stove compliant with 2020 cord wood standard CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AN...

Page 2: ...lishes the warranty period If it can not be provided the warranty period will be determined by the date of manufacture of the product It is also highly recommended to register the warranty online at h...

Page 3: ...ducing Wall and Ceiling Clearances Safely 18 5 1 Shield Construction Rules 18 6 Installation of options on your product 21 6 1 Optional Fresh Air Intake Kit Installation 21 6 2 Optional Fire Screen In...

Page 4: ...Page 4 Installation and Operation Requirements Deco Alto ENGLISH 1 CERTIFICATION PLATE...

Page 5: ...um acceptable temperature in the designated area in case of a power failure 2 The overall firebox calculation is an approximation and is not intended to be used for loading This volume includes a buff...

Page 6: ...ULC S627 1 North south ends of the logs visible East west sides of the logs visible 2 Mobile homes Canada or manufactured homes USA The US Department of Housing and Urban Development describes manufac...

Page 7: ...5 8 651mm O 6 153mm Figure 1 Top View 22 3 4 578mm 16 3 4 425mm 10 1 4 260mm 17 1 8 435mm 12 1 8 307mm 21 3 8 543mm 26 1 2 674mm 7 3 8 188mm 12 7 8 325mm 25 5 8 651mm O 6 153mm 22 3 4 578mm 16 3 4 42...

Page 8: ...H 2 3 2 Combustion Chamber Dimensions 17 1 2 444mm 9 227mm Figure 4 Door Opening 21 533mm 5 16 8mm 3 16 5mm 11 7 8 303mm 16 1 2 419mm 21 533mm 5 16 8mm 3 16 5mm 11 7 8 303mm 16 1 2 419mm Figure 5 Fron...

Page 9: ...e front of the firebox and there are only faint flames on the wood in the back of the firebox break ashes level the coal bed and put five logs in the firebox Put 3 pieces on the coal bed without air s...

Page 10: ...learances of the appliance and the flue pipes must be met individually meaning the appliance cannot be installed closer to the combustible materials than the single or double wall pipe allows For a sa...

Page 11: ...11 Installation and Operation Requirements Deco Alto ENGLISH A B E D CAN 48 122 cm US 36 92 cm 48 Flush F F C Figure 7 Clearances Top Figure 8 Clearances Corner 84 213 cm Ve Ho N Figure 9 Clearances...

Page 12: ...m 6 159 mm B 4 102 mm 4 102 mm E 13 337 mm 13 337 mm C 3 76 mm 3 76 mm F 12 318 mm 12 318 mm A B E D CAN 48 122 cm US 36 92 cm 48 Flush F F C If the clearance reduction is on the same side as the door...

Page 13: ...mm 12 305 mm L 77 196 cm 77 196 cm If the above clearances are met then the distances measured from the flue outlet will be DISTANCES1 FROM PIPE CONNECTOR WITH SINGLE WALL PIPE CONNECTOR DISTANCES1 F...

Page 14: ...IANCE CLEARANCES WITH DOUBLE WALL PIPE CONNECTOR Canada USA A 5 127 mm 5 127 mm B 6 152 mm 6 152 mm C 5 127 mm 5 127 mm L 80 203 cm 80 203 cm Ve Ho L DISTANCES1 FROM PIPE CONNECTOR WITH DOUBLE WALL PI...

Page 15: ...2 311 mm 12 311 mm E 32 819 mm 32 819 mm A B E D K E B 3 1 5 Mobile Home It is strictly forbidden to install a unit with a single wall pipe in a mobile home APPLIANCE CLEARANCES WITH DOUBLE WALL PIPE...

Page 16: ...CONNECTOR DISTANCES1 FROM PIPE CONNECTOR WITH DOUBLE WALL PIPE CONNECTOR Canada USA Canada USA A 3 76 mm 3 76 mm D 6 159 mm 6 159 mm B 6 152 mm 6 152 mm E 15 387 mm 15 387 mm C 3 76 mm 3 76 mm F 12 31...

Page 17: ...49 mm T 33 851 mm 26 673 mm U 41 1057 mm 32 832 mm V 68 1734 mm 53 1365 mm H I G J K S Figure 10 Floor Protection U T V 84 213 cm Ve Ho N 1 In Canada to comply with CSA B365 Installation Code for Soli...

Page 18: ...in this case the same clearances as a certified double wall pipe connector can be used Refer to the booklet in the screen options to obtain the dimensions to be respected 5 1 Shield Construction Rule...

Page 19: ...age 19 Installation and Operation Requirements Deco Alto ENGLISH Figure 11 Heat shield clearances Figure 12 Heat shield clearances H H Figure 13 Heat shield clearances Figure 14 Heat shield clearances...

Page 20: ...l on non combustible board spaced out at least 1 25 mm by non combustible spacers 50 18 457 mm 33 24 610 mm Ceramic tiles or equivalent non combustible material on non combustible board with a minimum...

Page 21: ...ptional Fresh Air Intake Kit Installation This mobile home approved stove requires the installation of a fresh air intake kit A and an insulated fresh air intake pipe HVAC type must meet ULC S110 or U...

Page 22: ...een is prohibited It is prohibited to use this wood stove with a fire screen in a mobile home 1 Open the door 2 Hold the fire screen by the two handles and bring it close to the door opening 3 Lean th...

Page 23: ...he instructions provided with the thermodisc for more details 1 Remove the backplate by cutting the knockouts with pliers 2 Screw the blower D in place using the screws C included in the installation...

Page 24: ...en lift and insert the left end of the tube into the rear left channel 2 Align the notch in the left end of the tube with the key of the left air channel hole Using a Wise grip hold the tube and lock...

Page 25: ...n and Operation Requirements Deco Alto ENGLISH Note that secondary air tubes B can be replaced without removing the baffle board A and that all tubes are not necessarely identical look at the part num...

Page 26: ...ion Requirements Deco Alto ENGLISH 6 5 Mobile Home Installation THE IMAGES SHOWN ARE FOR GUIDANCE ONLY AND MAY BE DIFFERENT FROM YOUR PRODUCT BUT THE ASSEMBLY REMAINS THE SAME Screw the base on the fl...

Page 27: ...ler to obtain a genuine replacement part To remove or replace the glass D THE IMAGES SHOWN ARE FOR GUIDANCE ONLY AND MAY BE DIFFERENT FROM YOUR PRODUCT BUT THE ASSEMBLY REMAINS THE SAME E D C A B 1 Re...

Page 28: ...7 Pinch the gasket onto the glass in a U shape all around the glass By following these instructions the edge clearances are maintain 7 3 Door In order for the stove to burn at its best efficiency the...

Page 29: ...crews located on the lower and upper hinges of the door using a 3 32 Allen key to free the adjustable hinge rods Using a flat screwdriver turn the adjustable hinge rods in the direction shown to adjus...

Page 30: ...asket from the door Use a screwdriver to scrape the old gasket adhesive from the door gasket groove 3 Apply a bead of approximately 3 16 5 mm of high temperature silicone in the door gasket groove Sta...

Page 31: ...ion Requirements Deco Alto ENGLISH 8 Exploded Diagram and Parts List 6 1 2 3 4 5 7 8 9 10 11 12 13 14 15 17 16 18 19 20 20 20 21 19 20 20 20 19 20 20 20 19 20 20 20 21 20 20 21 23 22 26 25 27 28 29 30...

Page 32: ...REWS 12 PER KIT 1 11 SE74183 GLASS WITH FRAME AND RETAINERS 1 12 30507 BLACK TORX SCREW WITH FLAT HEAD TYPE F 1 4 20 X 3 4 3 13 PL74181 AIR CONTROL HOUSING PLATE 1 14 PL74180 ASH SHELF 1 15 PL74184 AS...

Page 33: ...tallation and Operation Requirements Deco Alto ENGLISH Item Description Qty 36 30898 ROUND WOODEN BLACK HANDLE 2 37 30187 STAINLESS WASHER ID 17 64 X OD 1 2 2 38 30025 1 4 20 X 1 2 PAN HEAD QUADREX BL...

Page 34: ...manufacturer at its discretion may decide to repair or replace any part or unit after inspection and investigation of the defect The manufacturer may at its discretion fully discharge all obligations...

Page 35: ...Page 35 Installation and Operation Requirements Deco Alto ENGLISH...

Page 36: ...al com This document is available for free download on the manufacturer s website It is a copyrighted document Resale is strictly prohibited The manufacturer may update this document from time to time...

Reviews: