Escape 1800 Insert Installation and Operation Manual
54
Appendix 4: Top Surround and Shelf Heat Shield Installation
(AC01317)
When a heat shield is installed, you can reduce the clearances to the mantle shelf and the
top surround as followed (*refer to
Section 8.3
Compliance of a Combustible Mantel
Shelf
for additional details).
MAXIMUM MANTEL
SHELF DIMENSION (X)*
MANTEL SHELF
CLEARANCES (I)
TOP SURROUND
CLEARANCES (H)
8" (203 mm)
12" (305 mm)
11" (279 mm)
10" (254 mm)
14" (356 mm)
12" (305mm)
16" (406 mm)
Install the heat shield (A) on the
faceplate (assembled with the
faceplate extension) using 3 self-
drilling screws (B) included in the
kit. The heat shield should be
pointing upwards.
Once the heat shield is positioned,
install the faceplate on the insert as
in
Appendix 3:
Faceplate and